Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 71/83 succeeded

Total time taken: 369.2

OpenModelica Version: OMCompiler v1.12.0-dev.395+gdeeabde

Test started: 2017-05-05 07:02:15

Tested Library: ThermoSysPro 3.1( revision 3.1+OSR-10-g335e431 )

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("-d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection,execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50229.5127.217.3671.83.7589.12625.18
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim) 123.817.3969.123.0888.87625.38
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0.083666.8153.650.092880.015940.074563.002
ThermoSysPro.Examples.SimpleExamples.TestBend0.15619.1482.8932.7460.031490.11333.39
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump (sim)2.4048.122.3041.6450.047040.15533.994
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1 (sim)0.42328.4592.8541.7170.093960.26353.551
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump100.56739.1682.5113.1130.041470.14543.375
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump11 (sim)0.530510.482.933.6770.13830.18093.572
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)1.3597.3852.3361.650.031160.1113.275
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump130.66377.3312.2131.5120.029190.10693.489
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump21.6189.7532.7973.2640.038140.14633.529
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)4.3347.7412.1912.0270.050040.1583.341
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4 (sim) 7.822.7671.410.060840.15473.461
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump5 (sim) 7.2322.1391.6510.035580.12073.311
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump61.5529.012.35330.041580.33853.317
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 9.8512.5553.6630.05530.18533.414
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim)0.27997.6422.1022.1520.033630.12063.257
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim) 7.642.2411.9190.0580.20393.404
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0.062044.4571.5180.074080.074890.058632.752
ThermoSysPro.Examples.SimpleExamples.TestCheckValve3.73611.323.4163.5090.053110.34334.047
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0.111310.273.4021.5660.039811.0464.236
ThermoSysPro.Examples.SimpleExamples.TestControlValve0.13829.483.0552.5520.038470.31553.554
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm0.1289.52.5722.7830.036840.40033.75
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim) 7.6232.4891.550.036540.14313.426
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim) 8.5562.1581.7860.089980.20754.347
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim) 11.142.8973.5330.055030.18584.492
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve1.00110.642.8852.9070.84530.10813.94
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum10.9920.924.5047.6020.59271.0287.244
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum111.0521.464.8968.2470.44061.0836.818
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe2.69312.813.4322.8070.30630.60195.685
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim)7.9439.7812.823.2280.045260.15353.555
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe3.95518.144.1185.9030.39921.2436.517
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim)37.0142.096.12622.951.2322.2289.583
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger1.49610.873.012.450.085280.35014.99
ThermoSysPro.Examples.SimpleExamples.TestFan3.8967.43.0380.40350.036110.16163.781
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions0.18436.6343.140.094820.021180.069383.328
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes0.99177.0143.1740.25290.041630.16853.398
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes10.31416.4713.1180.25260.022530.074843.022
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve5.3759.7352.5923.4180.061330.25643.432
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve0.72249.0532.632.6090.027350.67073.134
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0.11738.4452.1612.4040.022470.76663.144
ThermoSysPro.Examples.SimpleExamples.TestJunctions0.78229.6272.2433.1080.043280.1554.099
ThermoSysPro.Examples.SimpleExamples.TestJunctions21.20510.062.7263.3170.056090.2043.777
ThermoSysPro.Examples.SimpleExamples.TestJunctions3 (sim)7.4699.5322.5443.2680.051660.18563.504
ThermoSysPro.Examples.SimpleExamples.TestJunctions40.36959.9282.4073.9890.031510.1213.401
ThermoSysPro.Examples.SimpleExamples.TestJunctions53.759.9992.863.4030.052880.18813.518
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker0.39937.4542.2851.5750.033060.1353.455
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe3.949.0412.4172.8290.036630.13983.64
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier0.29087.2792.2321.9080.025210.10243.031
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim)2.0029.9342.4423.7830.050070.1783.501
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim)22.0192.3982.8120.05840.18063.574
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim) 9.9312.413.2030.080610.30753.95
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss0.1268.5262.4132.6030.021970.22563.283
ThermoSysPro.Examples.SimpleExamples.TestRefP0.24517.3122.4541.4570.027120.11533.283
ThermoSysPro.Examples.SimpleExamples.TestSensors0.29399.1092.472.7070.027620.11233.812
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases0.42449.9044.6541.3350.030810.13143.774
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser0.75428.3652.5381.7240.034910.15483.957
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss0.13488.7452.2952.7010.02350.29393.454
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim)1.2417.6242.0571.9850.038170.14143.495
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump10.11849.2792.5262.6850.022690.56823.502
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump21.797.1422.1451.510.03370.13393.338
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0.053864.7331.5750.075790.07480.060112.967
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim)144.410.32.6193.310.064540.26524.06
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum1 (sim) 9.3312.382.5040.047460.84113.591
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum20.63298.7132.5372.6410.032670.32533.197
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases0.34039.9574.4381.3260.10720.38083.729
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger0.97168.3032.5741.7960.034140.16283.757
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff0.55817.6082.3681.5720.039730.16073.495
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer0.45439.3012.5592.9070.031710.12263.7
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)0.69068.5292.1172.760.029640.29953.342
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine0.23889.5843.1612.4970.033490.14533.767
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter0.51969.3242.3863.3120.032460.11953.494
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine3.03811.93.1994.3220.063260.18314.161
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine10.949612.063.3484.7910.048220.18943.699
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine20.35510.792.9534.1260.037270.3023.39
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine3 (sim) 11.783.2834.3840.047020.16983.916
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve0.25548.8462.5512.5980.032330.27493.433
ThermoSysPro.Examples.SimpleExamples.TestTank1.8859.1812.4082.890.033270.19623.673
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve0.74188.9612.6852.8180.032160.12623.318
ThermoSysPro.Examples.SimpleExamples.TestVolumes5.26810.262.7833.6290.063730.22793.584
ThermoSysPro.Examples.SimpleExamples.TestVolumes15.2239.5132.9272.9230.053840.20493.424
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim)17.9610.072.9643.3010.053350.19183.582
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 9.8882.6073.4080.10080.33433.459

Offline version