Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 72/83 succeeded

Total time taken: 471.9

OpenModelica Version: OMCompiler v1.12.0-dev.364+g8429f94

Test started: 2017-04-13 07:04:34

Tested Library: ThermoSysPro 3.1( revision 3.1+OSR-10-g335e431 )

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("-d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection,execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50234.8128.916.674.753.5968.8425.1
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim)334.212616.8972.554.0618.29624.18
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0.077526.9553.7350.093030.014890.070113.061
ThermoSysPro.Examples.SimpleExamples.TestBend0.19869.6872.9922.9490.3820.11453.268
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump (sim)2.0368.6122.7951.8040.0640.20493.787
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1 (sim)0.40547.9552.3791.5370.045870.15043.861
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump100.49789.522.7883.2880.034910.13343.294
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump11 (sim)0.55069.5482.7113.1420.05160.15373.51
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)1.3347.62.2992.0480.049560.11873.103
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump130.68417.4732.2941.8820.030970.15533.132
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump21.5049.0332.6632.7660.035260.13763.45
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)4.4527.3262.3161.470.045510.1483.365
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4 (sim) 7.3512.4251.4390.044940.14473.316
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump5 (sim) 6.9912.3921.3780.032310.11053.096
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump61.5058.8042.612.7860.054010.13863.252
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 9.592.5693.2330.061890.19573.554
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim)0.27087.4452.171.8880.034050.11953.252
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim) 7.4672.2231.8750.030420.11013.247
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0.078414.7551.7030.077620.078090.058552.858
ThermoSysPro.Examples.SimpleExamples.TestCheckValve3.37211.092.6394.1310.051950.1924.1
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0.094148.7573.0131.3390.16770.14794.108
ThermoSysPro.Examples.SimpleExamples.TestControlValve0.19239.272.6492.7010.028030.12323.79
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm0.14999.5852.6062.8990.022460.57753.51
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim) 8.1552.3512.0470.035360.13893.611
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim) 8.4472.3631.8260.035280.29193.962
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim) 11.072.9973.5630.051560.27254.202
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve0.634710.052.5943.0190.023370.77173.657
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum11.0620.113.9217.4570.42171.1297.205
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum111.5720.354.0527.2740.48491.0327.529
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe2.66213.233.1573.3190.16551.515.094
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim)7.43710.042.5393.6830.047760.13893.677
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe3.75517.373.9085.8860.35490.87966.363
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim)37.1941.185.62621.951.1772.6549.796
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger1.56810.753.0482.0690.087570.33885.224
ThermoSysPro.Examples.SimpleExamples.TestFan3.7857.983.5480.20610.04290.18224.02
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions0.20897.0712.9460.20340.034260.10243.838
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes0.99457.0253.1330.26970.042110.13963.46
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes10.32076.2642.9190.11170.024050.075933.152
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve5.5239.9522.9013.3950.049950.20043.423
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve0.77298.7462.4122.4740.026720.75693.095
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0.14428.4962.3022.4820.019730.095543.616
ThermoSysPro.Examples.SimpleExamples.TestJunctions0.80839.1712.352.8640.053550.1543.782
ThermoSysPro.Examples.SimpleExamples.TestJunctions21.15210.852.6293.6650.056760.18994.332
ThermoSysPro.Examples.SimpleExamples.TestJunctions3 (sim)8.04910.392.5083.3670.044060.17224.319
ThermoSysPro.Examples.SimpleExamples.TestJunctions40.39939.632.253.6210.03090.44243.308
ThermoSysPro.Examples.SimpleExamples.TestJunctions53.61410.372.5783.40.052120.18964.166
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker0.34847.2472.1731.7280.026580.10783.233
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe4.1488.7342.4442.6980.035340.15973.431
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier0.27987.2072.0751.690.024190.099013.336
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim)1.67110.172.3294.0230.048490.16693.62
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim)21.189.0392.3362.980.069490.183.495
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim) 9.5432.5492.8650.15030.25573.741
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss0.16958.5042.2652.7680.020580.26783.206
ThermoSysPro.Examples.SimpleExamples.TestRefP0.22677.262.3461.3850.028880.11853.403
ThermoSysPro.Examples.SimpleExamples.TestSensors0.2659.8682.4393.7530.030520.11453.562
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases0.3959.3534.3371.2960.1780.12993.575
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser0.67.6152.2531.6290.033160.18893.531
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss0.12278.7152.4412.7020.021850.24983.32
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim)1.1917.0642.0611.6830.029680.11193.195
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump10.12448.8882.2012.6720.024620.73243.278
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump21.9037.1682.171.7060.030160.11043.171
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0.087674.731.6560.082040.080140.059142.873
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim)143.610.592.6443.8290.053240.19743.884
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum1 (sim) 9.0662.232.7050.034240.4063.709
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum20.62498.7342.1912.6570.035130.54033.331
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases0.39179.3054.2151.2760.027420.26383.542
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger0.31517.9332.4481.6250.036070.14593.697
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff0.57468.0842.5071.3580.034210.74463.46
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer0.4769.1712.4463.1710.057160.13593.419
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)0.50669.3012.2972.9650.030320.67073.356
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine0.26029.543.0342.3270.031360.13814.028
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter0.60449.3332.3153.2580.027260.11453.637
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine2.91211.473.2334.3290.049960.20533.669
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine10.989211.63.0864.6710.044410.16793.656
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine20.377310.682.9913.9790.048260.16993.547
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine3 (sim) 11.083.0344.1370.044550.17013.714
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve0.20638.5292.3022.4890.020830.19793.539
ThermoSysPro.Examples.SimpleExamples.TestTank1.8789.482.493.4170.032120.12263.437
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve0.6599.4652.5943.4250.034620.13473.296
ThermoSysPro.Examples.SimpleExamples.TestVolumes5.15810.042.6683.7110.065940.20353.407
ThermoSysPro.Examples.SimpleExamples.TestVolumes15.66310.072.8723.5220.055480.22023.425
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim)18.418.9332.4842.7990.081790.21293.389
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 9.8322.5693.5360.10480.21563.429

Offline version