Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 72/83 succeeded

Total time taken: 709.7

OpenModelica Version: OMCompiler v1.12.0-dev.248+g64ce9d9

Test started: 2017-03-01 11:36:15

Tested Library: ThermoSysPro 3.1( revision 3.1+OSR-10-g335e431 )

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("-d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection,execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50255.6119.817.1566.413.2678.24224.79
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim)346.812216.5268.553.6838.724.52
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0.11087.2213.960.10160.019780.083583.099
ThermoSysPro.Examples.SimpleExamples.TestBend0.24919.3742.7523.0810.026490.2233.311
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump (sim) 8.1832.5291.9370.046370.21363.476
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1 (sim)0.42657.9272.421.7230.042690.30743.466
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump100.54879.6162.8463.1140.045380.14733.49
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump11 (sim)0.50639.6452.9163.1330.035760.13143.449
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)1.3127.7622.6611.7310.02870.11763.243
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump130.5377.4782.2361.7520.025960.12213.37
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump21.7579.3572.4973.0050.037070.15223.688
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)5.5437.7212.5651.5270.045150.16583.439
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4 (sim) 7.472.3051.540.048790.16143.442
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump5 (sim) 7.1452.1131.3960.037160.12923.493
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump61.5769.3122.5842.9590.038580.15313.597
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 10.332.7083.3950.060090.21053.98
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim)0.33357.6972.1721.8620.030750.12413.532
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim) 8.0832.1921.8890.032070.20143.787
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0.16725.5471.7340.077380.077070.063473.615
ThermoSysPro.Examples.SimpleExamples.TestCheckValve3.59111.532.8294.1760.10560.20954.226
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0.10699.7833.0271.5530.058280.73184.464
ThermoSysPro.Examples.SimpleExamples.TestControlValve0.24669.5942.6912.8030.063630.28833.766
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm0.265110.112.8222.7540.027580.68013.89
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim) 7.9772.161.9920.034050.15043.669
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim) 8.5352.1861.8680.040660.12144.347
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim) 10.942.7173.4850.04880.46944.237
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve0.778110.492.8352.8340.027170.87023.943
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum11.5419.934.1987.5330.37711.2026.663
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum110.8519.84.4387.0080.38071.0956.9
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe2.84911.132.8782.6810.18360.55474.857
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim)6.5549.0652.4562.7090.14790.14873.623
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe4.10215.43.5624.4130.33981.026.089
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim)37.3138.735.50918.730.91073.41410.18
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger1.5579.2583.0651.7470.076620.33824.054
ThermoSysPro.Examples.SimpleExamples.TestFan3.536.6652.6970.16540.033650.26833.521
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions0.2256.072.7750.088090.020490.067673.14
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes0.92087.6643.4680.36410.036510.23.614
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes10.31595.9292.7260.097180.022130.080113.024
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve23.510.643.1393.4610.059880.21533.811
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve0.78328.3222.4012.50.19310.12433.125
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0.14158.3962.2662.4450.020790.113.577
ThermoSysPro.Examples.SimpleExamples.TestJunctions0.8078.7972.3162.8090.038460.16993.482
ThermoSysPro.Examples.SimpleExamples.TestJunctions21.1589.8672.4793.4190.055080.2463.688
ThermoSysPro.Examples.SimpleExamples.TestJunctions3 (sim)68.329.6122.7063.2280.045440.18063.484
ThermoSysPro.Examples.SimpleExamples.TestJunctions40.492610.592.5374.5930.033610.13113.321
ThermoSysPro.Examples.SimpleExamples.TestJunctions53.97310.12.6283.4970.054060.20823.738
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker0.43047.4752.1072.0180.025230.11673.234
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe3.9879.2012.4012.7180.0360.14313.922
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier0.29057.4882.1641.8150.023730.10453.399
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim)1.79510.682.2174.5140.050890.20543.713
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim)23.129.112.3012.7080.053860.21593.85
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim)19.299.9382.4052.8520.099170.36164.253
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss0.17548.3092.2852.6310.022390.10673.283
ThermoSysPro.Examples.SimpleExamples.TestRefP0.23727.6512.5081.4450.025780.14663.558
ThermoSysPro.Examples.SimpleExamples.TestSensors0.35719.1112.5192.8010.03110.12183.658
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases0.40869.3694.2111.4460.028910.13893.567
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser0.71727.8992.4741.690.033970.15083.571
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss0.19379.1422.1772.660.024550.76713.533
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim) 7.6092.1311.8370.036270.11843.513
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump10.18018.8942.3272.5490.025260.13063.883
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump21.7587.6362.1661.8520.031160.14283.468
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0.057554.8581.6520.071660.082210.063223.012
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim)4419.7182.6632.9360.081970.20063.857
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum1 (sim) 9.1292.2622.4860.034650.82043.545
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum20.61438.922.3462.8790.033180.22653.457
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases0.41439.4824.2071.5130.026250.12113.632
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger0.45988.0322.3861.6260.035380.163.845
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff0.69527.7452.4351.5850.036550.14323.567
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer0.53748.7252.4992.6530.031020.17153.391
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)0.55728.892.1992.80.029430.12373.756
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine0.46459.8663.0362.820.034020.14973.846
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter0.55349.2732.4733.1020.031610.13383.555
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine3.06611.893.1954.630.05080.18773.844
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine11.33511.533.1514.2410.050210.2063.904
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine20.559511.313.063.6680.039220.94163.621
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine31.1311.422.9994.0320.18920.19984.025
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve0.24448.4212.3552.5250.024260.23473.3
ThermoSysPro.Examples.SimpleExamples.TestTank1.8679.0342.4773.120.03310.13283.291
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve1.1558.6872.2592.9480.032390.13613.33
ThermoSysPro.Examples.SimpleExamples.TestVolumes5.34210.322.6033.4820.05360.20963.995
ThermoSysPro.Examples.SimpleExamples.TestVolumes15.24510.292.4923.7410.057150.21523.808
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim)18.439.6252.6593.2130.054350.20263.519
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 10.232.9183.5170.099690.22663.5

Offline version