Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 72/83 succeeded

Total time taken: 701.1

OpenModelica Version: OMCompiler v1.12.0-dev.195+gd2bbe7a

Test started: 2017-02-08 07:02:55

Tested Library: ThermoSysPro 3.1( revision 3.1+OSR-10-g335e431 )

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("-d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection,execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50249.3124.816.9768.953.6989.1426.06
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim)363119.716.5366.833.2637.8225.32
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0.07027.1093.8750.1140.015320.074013.051
ThermoSysPro.Examples.SimpleExamples.TestBend0.20389.6372.5782.8450.025740.93013.277
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump (sim) 8.3192.4331.8140.043490.13563.911
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1 (sim)0.41757.7122.4641.4490.039230.15163.627
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump100.55799.5412.7173.1290.038690.15313.521
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump11 (sim)0.53729.6883.252.8070.03870.13953.473
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)1.2557.8142.2091.9870.029040.1353.475
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump130.52467.4462.1591.8420.027420.21863.219
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump21.4518.8352.4492.8920.033980.14423.336
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)4.3797.5042.3651.5770.057670.15933.373
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4 (sim) 7.4462.2781.6170.044670.1533.385
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump5 (sim) 7.3412.0371.6460.032010.19033.456
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump61.6429.4292.4383.260.035710.14543.57
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 9.7282.4123.3220.052170.24073.743
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim)0.28237.3062.1791.7680.029950.12313.224
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim) 8.1361.9811.6480.032870.19064.303
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0.056535.4831.8740.13910.10340.056143.328
ThermoSysPro.Examples.SimpleExamples.TestCheckValve3.757112.8713.2540.048270.24664.598
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0.090129.1623.0921.3790.03560.32564.348
ThermoSysPro.Examples.SimpleExamples.TestControlValve0.20310.112.6172.9390.027770.82493.724
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm0.18859.3162.4453.030.027860.27193.561
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim) 7.7582.291.6460.03360.13113.679
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim) 8.4022.3291.9990.032750.15963.905
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim) 11.052.9263.7630.10260.18884.099
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve0.808910.722.8073.2970.024670.66813.937
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum13.6819.223.866.6850.52141.1077.07
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum111.6519.084.1046.8760.52331.1626.436
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe2.96410.282.9472.0890.14140.64924.473
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim)6.8628.6952.3072.8470.043110.15183.364
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe4.04916.523.8315.6850.3270.91055.786
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim)34.6138.75.50219.441.0832.68210.01
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger1.5249.7782.9872.0930.077630.27174.37
ThermoSysPro.Examples.SimpleExamples.TestFan3.566.2942.7170.15810.031480.27493.133
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions0.17116.8852.8250.089750.020560.069433.904
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes0.83926.8762.950.23140.19770.12133.395
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes10.38635.7092.5320.094560.021450.080343
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve23.469.9812.5933.3530.05640.26443.734
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve0.80048.8772.4122.4770.63450.13383.24
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0.14338.7772.3912.5260.023910.10843.75
ThermoSysPro.Examples.SimpleExamples.TestJunctions0.75769.3432.4713.3480.041540.16313.339
ThermoSysPro.Examples.SimpleExamples.TestJunctions21.2279.7392.5023.3940.0510.19943.611
ThermoSysPro.Examples.SimpleExamples.TestJunctions3 (sim)68.299.8352.5713.460.04560.17653.604
ThermoSysPro.Examples.SimpleExamples.TestJunctions40.41859.8092.2884.0350.035370.14213.328
ThermoSysPro.Examples.SimpleExamples.TestJunctions53.69710.132.6663.4410.058920.2343.748
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker0.34546.9712.1321.3190.025320.11153.403
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe4.0299.2772.3343.1450.033860.13883.644
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier0.29687.3812.271.7460.023460.10453.256
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim)1.92510.132.4223.9780.047620.18233.522
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim)23.029.4242.3653.1920.052170.19093.645
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim)20.3110.232.3453.5670.086870.2963.951
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss0.16299.1892.3162.6040.039721.0733.176
ThermoSysPro.Examples.SimpleExamples.TestRefP0.23137.1582.2561.4320.026440.11663.347
ThermoSysPro.Examples.SimpleExamples.TestSensors0.33259.7052.4662.7141.0290.11683.399
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases0.43889.2574.0641.3660.027070.12833.692
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser0.71678.1942.5151.6870.033060.14793.829
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss0.19558.5162.2942.6980.03020.25723.255
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim) 7.7152.3621.8050.027690.11773.422
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump10.18488.6122.3432.5210.023040.23613.508
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump21.8447.8712.2951.9120.02780.11513.542
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0.059664.9281.6850.065670.078620.057793.059
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim)43410.142.5623.2130.05170.19784.132
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum1 (sim) 8.5822.2142.520.12330.30213.441
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum20.66288.7252.1462.4750.028750.65023.445
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases0.33839.3233.9831.6220.025780.12923.581
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger0.39818.2352.6041.6090.03610.24333.762
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff0.64197.5572.5271.5110.034330.14283.361
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer0.53989.232.2723.2390.031970.12723.582
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)0.54578.5052.1372.460.029530.1223.777
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine0.45259.5452.9832.810.057710.15083.565
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter0.56959.3022.4343.2210.027290.12213.517
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine3.36511.383.1824.0770.050070.19123.897
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine11.43811.263.0524.2060.051510.18733.788
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine20.557810.993.1813.3080.035840.92393.559
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine31.04510.723.2113.5880.055320.19833.689
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve0.39098.5842.2482.7220.023020.33653.287
ThermoSysPro.Examples.SimpleExamples.TestTank1.9919.5012.6863.370.033110.13363.297
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve0.78648.6972.3282.8220.037540.16513.364
ThermoSysPro.Examples.SimpleExamples.TestVolumes5.30410.012.6083.4420.055710.26233.709
ThermoSysPro.Examples.SimpleExamples.TestVolumes15.33310.612.6193.440.081350.22254.286
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim)18.739.8692.8353.3250.057460.20633.465
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 10.192.9993.490.091670.21483.416

Offline version