Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 73/83 succeeded

Total time taken: 512.8

OpenModelica Version: OMCompiler v1.12.0-dev.77+g56dc448

Test started: 2016-12-24 05:44:12

Tested Library: ThermoSysPro 3.1( revision 3.1+OSR-10-g335e431 )

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("-d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection,execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50232.2114.316.4364.392.9087.84322.71
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim)319.7114.616.5764.493.6227.66222.26
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0.11576.8463.6610.091880.015180.07043.028
ThermoSysPro.Examples.SimpleExamples.TestBend0.17569.0272.9182.8480.026170.1283.125
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump (sim) 7.8122.5791.4410.04710.26373.502
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1 (sim)0.40177.3292.2611.3130.041750.32873.403
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump100.61139.7573.0583.3240.060160.19693.136
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump11 (sim)0.53629.2612.9372.9780.03470.14413.192
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)1.3357.1482.3731.3050.028990.11263.351
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump130.51636.962.5451.2330.025750.10833.068
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump21.4828.5162.5082.5720.05640.15033.253
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)4.5727.6482.3941.2540.04190.83.187
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4 (sim) 7.8732.361.3050.053050.79113.389
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump5 (sim) 6.9042.1191.1940.031830.1383.443
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump61.5179.72.5493.5360.037520.15193.444
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 9.6282.7823.2940.057490.19073.459
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim)0.32867.0622.3071.3030.56450.12663.322
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim)0.053527.772.3521.3020.03040.12073.986
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0.05995.3331.6340.07650.078540.059573.504
ThermoSysPro.Examples.SimpleExamples.TestCheckValve3.56611.392.7864.080.043360.24494.253
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0.085839.6573.4192.0340.0320.15354.037
ThermoSysPro.Examples.SimpleExamples.TestControlValve0.23939.5422.852.9170.025220.10943.659
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm0.20918.8992.5152.7170.050390.10763.553
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim) 7.572.3811.2950.032230.20263.692
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim) 7.9182.5421.2920.029880.13153.949
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim) 10.372.4933.8260.20320.16253.881
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve0.75410.092.6483.1810.027320.10514.151
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum11.0719.953.9677.7490.33941.3986.512
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum111.0318.884.3626.1250.35091.3526.711
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe2.81810.783.0022.1650.13280.50894.988
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim)7.049.3272.4213.1110.038370.16653.609
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe3.86315.614.1664.3550.33570.84435.927
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim)34.0238.615.38520.351.0832.5329.281
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger1.5358.7452.7141.6760.067460.33463.973
ThermoSysPro.Examples.SimpleExamples.TestFan3.6876.122.6510.14630.03540.1243.2
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions0.21025.892.3690.23980.02040.066383.216
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes0.9276.7652.8960.20130.036790.12173.529
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes10.32655.8022.4680.31970.02060.072292.942
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve5.14510.322.5793.2760.048260.82833.61
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve0.75738.8862.4433.1430.02510.11643.181
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0.13038.4462.3083.0280.021060.09713.011
ThermoSysPro.Examples.SimpleExamples.TestJunctions0.9038.9932.6562.8750.038180.15113.293
ThermoSysPro.Examples.SimpleExamples.TestJunctions21.1719.7922.6042.9390.058020.82733.409
ThermoSysPro.Examples.SimpleExamples.TestJunctions3 (sim)57.379.2152.5123.2410.040290.17173.272
ThermoSysPro.Examples.SimpleExamples.TestJunctions40.40649.7072.6683.7340.027550.12593.174
ThermoSysPro.Examples.SimpleExamples.TestJunctions55.1738.932.4792.7330.043730.2913.402
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker0.36586.492.2171.1940.024890.10992.965
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe4.1159.2282.4953.0980.034280.66363.487
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier0.3426.9352.3421.2620.021880.10353.225
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim)1.81310.072.3654.0480.040970.28243.356
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim)21.28.8452.4122.7650.045580.18893.456
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim)18.199.8812.4993.1980.062420.44553.695
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss0.1838.7372.513.0250.041930.10423.098
ThermoSysPro.Examples.SimpleExamples.TestRefP0.20877.612.4231.8780.023860.11373.191
ThermoSysPro.Examples.SimpleExamples.TestSensors0.40129.2032.6253.3040.028040.12653.141
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases0.43839.7144.1361.9120.023180.10933.558
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser0.68738.6912.4562.410.028530.13623.679
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss0.17638.652.5282.9420.023440.10423.072
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim) 6.7842.2921.2910.026050.10863.086
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump10.18628.4252.3682.8190.025820.1173.115
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump21.7946.7332.1661.2510.029820.11733.192
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0.046665.3261.4660.070580.075620.063443.678
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim)253.99.7882.7153.7150.054780.18673.687
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum1 (sim) 9.472.533.2610.036660.14683.531
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum20.57238.9452.2273.220.028980.15423.335
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases0.31769.5044.1111.8640.027170.11063.412
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger0.40328.2252.5462.1380.03230.17143.355
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff0.66837.822.4931.3640.24490.12523.623
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer0.4968.7232.5372.6990.027440.12163.358
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)0.5828.4352.2712.8080.025660.13643.217
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine0.44818.9783.0442.2650.028550.2313.43
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter0.52339.2552.433.180.027980.13683.523
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine3.1811.393.3544.2080.046140.18353.616
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine11.30911.753.1744.7260.046740.173.656
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine20.584410.922.9434.4820.03220.13753.347
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine31.0211.33.1594.0010.044620.18083.938
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve0.22378.3962.4572.7780.022810.10043.057
ThermoSysPro.Examples.SimpleExamples.TestTank2.5259.4262.7252.7740.030850.12333.791
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve0.83879.252.383.1760.030050.13113.554
ThermoSysPro.Examples.SimpleExamples.TestVolumes5.32110.492.8573.0890.046420.18524.343
ThermoSysPro.Examples.SimpleExamples.TestVolumes15.38310.132.5373.5880.62280.18333.79
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim)18.579.62.723.3240.048240.19423.334
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 9.9512.7913.1950.087260.55753.338