Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 73/83 succeeded

Total time taken: 555.2

OpenModelica Version: OMCompiler v1.12.0-dev.54+gc3e6c1b

Test started: 2016-12-15 06:18:57

Tested Library: ThermoSysPro 3.1( revision 3.1+OSR-10-g335e431 )

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("-d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection,execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50237.4120.51769.133.8188.15522.38
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim)322114.316.8463.792.8988.10722.69
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0.085136.853.670.088740.014630.076633.021
ThermoSysPro.Examples.SimpleExamples.TestBend0.17818.8792.4093.080.025760.11773.265
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump (sim) 8.0042.5931.8010.043050.22223.363
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1 (sim)0.51197.8292.7231.4890.045050.15753.434
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump100.51489.6322.9543.2870.034740.16673.208
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump11 (sim)0.51339.7293.0973.2650.043610.13273.21
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)1.3317.4242.4781.4030.06480.35213.144
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump130.62387.2822.1611.3140.026630.40383.395
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump21.6859.0342.7242.6490.038080.27163.372
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)4.3367.32.2741.5160.07950.15733.292
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4 (sim) 7.2272.3661.4330.061440.15433.23
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump5 (sim) 7.4352.3611.3010.031660.24543.513
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump61.5979.4992.63.20.03960.15133.528
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 10.412.8663.0020.065730.80693.686
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim)0.36667.432.2831.3850.028560.22913.523
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim)0.034738.0682.4241.4670.03090.36533.804
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0.085595.181.710.074980.086470.064393.263
ThermoSysPro.Examples.SimpleExamples.TestCheckValve3.56310.552.8193.620.056580.18763.912
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0.13049.0813.1421.2540.036880.85213.817
ThermoSysPro.Examples.SimpleExamples.TestControlValve0.205310.262.5193.8150.024350.11883.806
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm0.30188.9592.6352.8480.026760.11893.373
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim) 7.7942.5671.2820.031570.50433.428
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim) 7.3872.2661.390.028950.28423.441
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim) 9.6192.5913.3440.050040.16763.486
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve0.74318.5142.3572.6840.025120.12923.339
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum10.5118.873.8357.1620.36331.1766.355
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum111.0416.954.2995.6140.35830.96345.741
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe2.7199.9533.1022.0470.14290.59444.086
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim)6.2078.7312.3933.0190.03880.15263.147
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe3.81715.563.9864.2180.49640.90975.966
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim)35.0238.145.78119.541.012.2819.551
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger1.5888.5972.7521.7410.13250.25363.737
ThermoSysPro.Examples.SimpleExamples.TestFan3.756.412.8580.15470.037590.13013.255
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions0.18626.0732.6820.081290.020340.071583.238
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes0.88496.6122.8330.19130.049850.19063.379
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes10.27565.5782.3530.21440.02180.076242.945
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve5.3989.2252.4872.960.049340.20273.565
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve0.80598.3882.4532.6430.029380.1143.167
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0.12127.9992.3942.5220.02370.099812.978
ThermoSysPro.Examples.SimpleExamples.TestJunctions0.74338.9812.5113.020.034610.15313.284
ThermoSysPro.Examples.SimpleExamples.TestJunctions21.1939.5562.5383.4470.045320.19943.346
ThermoSysPro.Examples.SimpleExamples.TestJunctions3 (sim)79.499.642.7432.8880.037580.1583.83
ThermoSysPro.Examples.SimpleExamples.TestJunctions40.3999.5122.4483.860.029050.24873.061
ThermoSysPro.Examples.SimpleExamples.TestJunctions54.0999.1922.7182.9890.045810.1843.276
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker0.33896.8722.3991.3410.024580.11563.022
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe4.2498.92.6762.8820.036650.14753.199
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier0.27986.5422.1281.1850.021440.25442.97
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim)1.8399.9192.4863.8110.042680.31283.285
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim)21.728.72.5862.6930.045890.18013.215
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim)18.2410.112.7413.2290.082670.47693.601
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss0.17898.1152.3212.6090.026230.13143.068
ThermoSysPro.Examples.SimpleExamples.TestRefP0.21576.8352.2991.350.024460.10893.071
ThermoSysPro.Examples.SimpleExamples.TestSensors0.3088.7432.3473.1350.038930.14043.108
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases0.38969.6334.5141.7990.023070.11393.203
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser0.65117.5132.6551.5480.027320.12773.176
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss0.16928.1642.4942.5950.023430.11122.983
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim) 6.5952.1791.1930.026990.22922.986
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump10.1888.9762.5743.1070.024980.10973.181
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump21.8186.922.2891.2210.042530.29593.088
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0.051114.4111.5380.07050.076250.061682.686
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim)257.29.1192.5922.9120.044570.35293.386
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum1 (sim) 8.1572.2652.6690.027750.12073.093
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum20.67558.9062.3482.8260.026610.12183.602
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases0.35579.2734.1011.7890.024890.11233.267
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger0.3818.1482.5232.0580.030520.23773.318
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff0.59647.3652.4981.530.029280.12813.203
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer0.48978.8612.4522.5880.029420.15423.656
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)0.53348.3972.0992.9150.031130.12253.249
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine0.50239.4953.2042.7580.029590.1483.385
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter0.5868.3972.4412.6120.026970.15363.182
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine3.22211.53.3364.2480.049940.20463.683
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine11.35211.253.2624.3030.043910.17283.487
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine20.545210.353.1543.4930.035850.28373.417
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine31.11211.222.9943.9880.70590.173.386
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve0.2428.7532.3163.1960.021980.099693.143
ThermoSysPro.Examples.SimpleExamples.TestTank2.5799.0422.4253.1010.031450.12933.374
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve0.77518.9482.4453.2360.029320.14083.117
ThermoSysPro.Examples.SimpleExamples.TestVolumes5.3679.5122.6672.9610.060590.61423.243
ThermoSysPro.Examples.SimpleExamples.TestVolumes15.3889.3772.4342.6910.045841.0053.22
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim)18.839.172.5432.7180.046970.72913.152
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 8.7852.5682.7430.085760.20463.203

Offline version