Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 71/83 succeeded

Total time taken: 473.9

OpenModelica Version: v1.11.0-dev.239+g3821a19

Test started: 2016-11-11 06:17:34

Tested Library: ThermoSysPro 3.1( revision 3.1+OSR-10-g335e431 )

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("-d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection,execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50231.1111.417.1761.413.4077.35522.11
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim)309.4114.916.0666.82.8747.54321.66
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0.065086.7843.5450.21920.014780.066822.958
ThermoSysPro.Examples.SimpleExamples.TestBend0.19569.7043.1223.4580.024240.1123.006
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump (sim) 7.5472.4721.2850.13050.2563.42
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1 (sim)0.43627.9462.7851.5620.042260.2663.31
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump100.6059.2582.7533.1960.036310.19463.097
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump11 (sim)0.4999.0472.8332.8060.033810.12593.268
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)1.2817.5212.5051.3540.028840.59033.064
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump130.50887.3532.3921.2760.024930.6193.059
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump21.5258.6222.5152.8020.034150.14293.148
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)4.4188.032.5932.1890.043790.14333.079
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4 (sim) 7.2072.331.6550.04230.14133.056
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump5 (sim) 7.2812.2911.2560.033150.26143.463
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump61.9119.0262.3952.7350.036740.20693.671
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 9.322.4372.6640.15480.33593.752
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim)0.3467.2382.3621.3710.036070.25883.299
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim) 7.9362.511.2520.036680.42823.733
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0.10555.0241.6040.073170.07570.058483.235
ThermoSysPro.Examples.SimpleExamples.TestCheckValve3.85210.373.0253.0210.047180.35883.94
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0.091848.5513.1211.5170.034110.1953.704
ThermoSysPro.Examples.SimpleExamples.TestControlValve0.21289.342.6112.7010.029790.10543.917
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm0.19529.3112.6532.8390.024610.10283.713
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim) 8.042.4181.3610.030960.32743.921
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim) 7.6672.651.4540.031390.22183.329
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim)115.19.8112.7613.2540.045020.16063.608
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve0.70818.2192.4252.4370.025590.10823.242
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum10.5917.053.8065.9390.381.2355.712
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum110.7717.224.3615.6790.52330.95115.719
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe2.6099.6782.9351.920.1390.52254.18
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim)7.4048.9792.433.270.042330.15993.102
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe3.71915.393.7144.1160.43881.475.669
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim)36.0136.835.71918.810.8772.0849.353
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger1.478.4682.7141.6660.068520.25533.783
ThermoSysPro.Examples.SimpleExamples.TestFan3.6656.0752.7840.13260.029720.11323.035
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions0.20515.7042.4810.083960.024340.073963.06
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes1.0076.6482.9980.1870.037930.13473.313
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes10.32285.552.4440.19530.021220.072122.837
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve24.179.5422.8273.1180.05310.18663.387
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve0.82398.6932.3723.0670.025240.11843.131
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0.15318.0292.3492.4290.023620.13773.115
ThermoSysPro.Examples.SimpleExamples.TestJunctions0.81299.2282.5683.2590.046430.15293.221
ThermoSysPro.Examples.SimpleExamples.TestJunctions21.18510.222.5663.2250.04860.84133.557
ThermoSysPro.Examples.SimpleExamples.TestJunctions3 (sim)55.819.1222.6682.830.38510.16763.439
ThermoSysPro.Examples.SimpleExamples.TestJunctions40.47219.262.363.6190.027420.25723.013
ThermoSysPro.Examples.SimpleExamples.TestJunctions54.1989.6642.5562.7190.045810.79943.565
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker0.45116.9042.2711.1710.023270.28723.188
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe4.0748.8252.5723.0050.047440.13793.101
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier0.31736.9232.3031.1710.022450.45152.994
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim)2.2389.612.433.650.038340.16083.352
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim)2.7818.7262.5662.5320.043230.1823.435
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim) 9.3842.4162.9760.092290.47523.444
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss0.22768.3412.342.9330.020380.096632.968
ThermoSysPro.Examples.SimpleExamples.TestRefP0.22827.2522.5091.4690.023790.10773.16
ThermoSysPro.Examples.SimpleExamples.TestSensors0.398.9982.5753.0370.025990.11393.268
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases0.3879.434.3051.2340.023530.2463.642
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser0.69227.9452.4962.1240.027920.13443.194
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss0.16188.1012.282.5990.020130.11433.107
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim) 6.6872.1531.1640.040430.22933.122
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump10.16178.7642.363.1770.023510.11243.115
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump21.7797.0082.281.2070.076180.43753.071
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0.061484.4971.5050.069620.076280.057382.808
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim)7.0129.292.5063.1180.047630.71233.433
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum1 (sim) 8.3052.0762.5440.028650.25463.421
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum20.55688.5912.62.6480.028720.16423.169
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases0.33858.7974.0451.2860.02380.10983.352
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger0.40978.0132.5931.990.034750.15543.27
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff0.61087.7412.4171.9250.030440.13083.257
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer0.52028.7682.4762.5880.026760.11993.576
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)0.5598.1432.2842.4790.034540.11063.253
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine0.46299.4763.1822.7190.029060.14153.426
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter0.55548.7232.4992.9960.028470.13223.086
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine3.28110.863.2883.4780.060140.21123.845
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine11.35611.233.344.0550.044130.22343.582
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine20.552310.733.1964.0120.038410.14983.353
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine31.4110.993.1513.9440.049030.17873.682
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve0.2598.0852.3912.5390.020880.10283.051
ThermoSysPro.Examples.SimpleExamples.TestTank2.5769.0612.3973.2410.031350.12593.286
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve (sim)0.76019.0822.4663.1440.034440.13343.324
ThermoSysPro.Examples.SimpleExamples.TestVolumes5.0359.1492.6922.8660.050450.34153.218
ThermoSysPro.Examples.SimpleExamples.TestVolumes15.4678.9552.5652.8580.048540.31543.187
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim) 9.0042.4672.6860.046690.75883.064
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 9.0022.4942.8340.086850.30683.298