Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 71/83 succeeded

Total time taken: 467.4

OpenModelica Version: v1.11.0-dev.173+g295a040

Test started: 2016-10-26 06:27:32

Tested Library: ThermoSysPro 3.1( revision 3.1+OSR-10-g335e431 )

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("-d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection,execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50238.5110.117.1760.152.5977.96222.21
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim)307.2115.216.8465.273.0648.34321.74
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0.085456.5453.320.1890.01480.087092.953
ThermoSysPro.Examples.SimpleExamples.TestBend0.17799.4212.9143.280.023860.21263.012
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump (sim) 8.2283.0641.4630.21150.12883.379
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1 (sim)0.47997.9812.7411.3220.041110.41213.483
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump100.55399.7672.7873.6440.031520.13393.189
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump11 (sim)0.55159.3962.8383.130.047270.12823.291
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)1.4427.3042.6061.2560.027860.26423.167
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump130.55396.8752.2961.2660.026650.21943.085
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump21.6338.9852.7433.0140.037140.14153.072
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)4.2227.3782.5721.4830.041350.23213.069
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4 (sim) 7.3572.6551.3560.044960.24633.083
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump5 (sim) 7.1272.2451.2110.032930.27373.388
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump61.759.6322.3573.3620.038070.14513.749
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 9.5612.7342.8030.051130.19273.799
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim)0.316.9162.1391.3610.044180.12973.27
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim) 7.8292.3291.2290.02960.24134.031
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0.10355.2581.6950.071960.13410.095623.282
ThermoSysPro.Examples.SimpleExamples.TestCheckValve3.45510.352.8363.3570.047010.31483.82
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0.10819.7233.7312.2040.056630.16833.585
ThermoSysPro.Examples.SimpleExamples.TestControlValve0.20819.8692.4773.6640.024160.11023.612
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm0.25149.1982.6112.8210.040420.14743.68
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim) 7.9222.5771.4090.043190.23443.689
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim) 7.2432.3721.3010.05540.26513.27
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim)111.99.5142.5753.3160.045930.16853.428
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve0.67998.6192.4042.6540.039220.11593.438
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum10.4318.953.8286.7710.5222.0345.812
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum110.7717.224.3975.760.47530.88695.722
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe2.7959.7152.8461.9190.16180.54144.267
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim)7.199.0612.4773.1290.036790.17893.259
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe3.69715.313.7634.4640.58080.97585.547
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim)34.9836.615.4119.320.87442.1528.897
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger1.5248.7122.7911.6350.086080.26173.975
ThermoSysPro.Examples.SimpleExamples.TestFan3.846.1852.790.13210.05470.14613.106
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions0.22825.2232.3370.070.019450.06762.748
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes0.90086.73.0450.17380.034910.12573.339
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes10.32575.4922.3880.20990.02090.077982.817
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve23.49.6172.6433.4160.05030.19563.333
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve0.82888.3742.5382.5420.025580.11543.171
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0.12158.322.422.8070.024380.10122.987
ThermoSysPro.Examples.SimpleExamples.TestJunctions0.75448.6692.5582.8180.035520.16233.115
ThermoSysPro.Examples.SimpleExamples.TestJunctions21.229.2712.5443.1990.20810.18993.313
ThermoSysPro.Examples.SimpleExamples.TestJunctions3 (sim)56.878.9962.6063.050.036870.15723.163
ThermoSysPro.Examples.SimpleExamples.TestJunctions40.36079.7012.3513.5570.028350.68043.105
ThermoSysPro.Examples.SimpleExamples.TestJunctions53.8899.7242.5713.0080.044820.31193.807
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker0.34156.8332.2611.2010.083110.28543.02
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe4.0278.7522.4872.9360.040550.16813.157
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier0.30266.8042.2491.2320.020770.47072.851
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim)1.9399.8092.4833.7030.045110.29843.3
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim)2.6258.4732.4312.5690.040640.16983.281
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim) 9.3572.5023.0010.063370.38393.427
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss0.22298.3612.4182.90.020120.097342.945
ThermoSysPro.Examples.SimpleExamples.TestRefP0.22258.2982.5211.8170.022730.10593.851
ThermoSysPro.Examples.SimpleExamples.TestSensors0.36889.2742.483.1980.064290.26893.284
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases0.44458.8774.0821.3330.02420.11333.345
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser0.72657.5782.5471.470.026210.13753.424
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss0.16098.1412.4352.4080.02090.11673.178
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim) 6.6652.3171.2460.027540.12672.969
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump10.19448.3842.3572.470.022220.12973.422
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump21.9066.8362.3381.3450.029520.20312.937
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0.056364.41.6250.07880.076430.061592.58
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim)7.1179.3552.5543.0350.041860.18683.556
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum1 (sim) 8.2832.282.4110.026750.12793.459
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum20.63568.3982.2292.5590.027720.11873.482
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases0.37819.2363.9981.7140.023490.11073.409
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger0.37698.3872.6322.0360.030150.15293.555
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff0.58188.1192.5082.1350.028810.13543.331
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer0.59678.9022.5212.8660.033030.16143.345
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)0.57058.1452.2262.5340.03760.14153.225
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine0.464193.0622.2460.028050.14933.535
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter0.60238.9042.3792.9240.027750.12223.471
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine3.1411.193.5993.7220.051740.20333.654
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine11.27411.073.3894.0930.043350.17083.392
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine20.581810.793.0794.0120.031250.17153.519
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine31.13110.33.3393.2820.039980.17123.485
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve0.23288.0592.272.5520.022110.1233.111
ThermoSysPro.Examples.SimpleExamples.TestTank2.7629.0752.4263.0530.029510.12543.459
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve (sim)0.7498.7472.5012.6430.030130.1613.431
ThermoSysPro.Examples.SimpleExamples.TestVolumes4.9579.492.6962.8880.047450.33633.54
ThermoSysPro.Examples.SimpleExamples.TestVolumes15.3528.8062.5032.7860.048310.32953.157
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim) 8.6892.4222.7890.04660.3083.143
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 9.0432.7882.6280.08580.30443.255

Offline version