Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 71/83 succeeded

Total time taken: 465

OpenModelica Version: v1.11.0-dev.154+gd75f648

Test started: 2016-10-21 06:41:01

Tested Library: ThermoSysPro 3.1( revision 3.1+OSR-10-g335e431 )

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("-d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection,execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50234.3113.716.5463.083.5667.98522.54
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim)301.5113.117.0962.652.7777.90922.74
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0.12366.7413.7370.090290.015970.07742.841
ThermoSysPro.Examples.SimpleExamples.TestBend0.17389.5422.8343.5570.026560.11913.024
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump (sim) 8.2512.8351.470.16350.23833.562
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1 (sim)0.45048.1982.9921.3310.23910.15843.496
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump100.5189.6572.8413.4520.046250.14183.197
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump11 (sim)0.52888.8862.8612.7890.03340.13653.093
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)1.247.6642.5141.3910.030580.65983.086
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump131.1436.8922.5071.2160.026470.11223.05
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump21.4818.9192.4413.090.032760.1643.21
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)4.2867.4742.6451.2960.041740.30443.204
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4 (sim) 7.4382.6841.3080.046210.23883.185
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump5 (sim) 7.1912.2751.2090.030810.33823.356
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump61.8279.3632.4653.0990.038590.16073.621
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 9.9472.4592.9960.086350.83.624
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim)0.32897.842.3371.3310.029640.79763.362
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim) 7.7652.2321.3340.57590.12834.073
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0.067985.6261.7580.18510.078960.063613.561
ThermoSysPro.Examples.SimpleExamples.TestCheckValve4.04610.662.9953.4580.064350.38793.775
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0.1048.5623.2211.5760.036950.1523.596
ThermoSysPro.Examples.SimpleExamples.TestControlValve0.18558.6532.4272.5740.024830.24633.401
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm0.25419.4182.6022.8450.02260.10173.867
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim) 8.1442.3321.4810.03410.73933.578
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim) 7.6112.451.2510.028470.66113.239
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim)117.59.5922.6663.2280.042340.17043.503
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve0.64258.7042.5262.6770.024320.10793.387
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum11.2217.253.8626.1470.34591.15.819
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum110.717.34.036.1880.33970.95625.808
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe2.629.6952.9491.9730.13460.49344.165
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim)7.3679.2712.6063.080.036510.19523.372
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe3.714.883.864.1610.32420.90065.658
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim)3436.985.77219.10.90482.2169.011
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger1.5839.0642.7441.9280.11480.25564.04
ThermoSysPro.Examples.SimpleExamples.TestFan3.3926.0062.8610.13290.028810.10783.066
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions0.21755.8782.7320.071850.020850.066573.008
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes1.0376.5882.6810.330.034650.1353.461
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes10.3175.7912.570.23870.021370.073382.907
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve24.049.4352.7362.8840.045430.37743.413
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve0.76698.3752.4962.6840.02680.11823.07
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0.13138.0362.4152.4830.029960.096683.035
ThermoSysPro.Examples.SimpleExamples.TestJunctions0.75089.2852.6163.1550.035050.15533.342
ThermoSysPro.Examples.SimpleExamples.TestJunctions21.16810.152.6613.2480.049080.78173.445
ThermoSysPro.Examples.SimpleExamples.TestJunctions3 (sim)53.959.6782.9723.2080.040070.17933.297
ThermoSysPro.Examples.SimpleExamples.TestJunctions40.43039.4782.473.6820.027590.12573.193
ThermoSysPro.Examples.SimpleExamples.TestJunctions53.9819.6392.5772.7290.04470.94153.365
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker0.33347.4192.3051.180.027270.79313.133
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe4.148.7392.4742.8460.037920.1433.278
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier0.29827.0662.2371.20.021820.62093.005
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim)1.96310.72.4224.5650.052620.34463.33
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim)2.6358.5052.2552.5660.041640.20923.454
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim) 9.6922.7413.1870.065360.26423.455
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss0.18818.3682.4332.5790.024790.11643.239
ThermoSysPro.Examples.SimpleExamples.TestRefP0.23347.3812.3671.4530.024830.11063.456
ThermoSysPro.Examples.SimpleExamples.TestSensors0.35718.752.3462.960.025040.1123.327
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases0.40679.1444.0951.3530.023710.11413.579
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser0.64057.582.4351.850.027310.12873.157
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss0.18468.3722.4862.5670.028090.11133.204
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim) 6.6032.1381.2370.02720.23162.989
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump10.19048.1642.3252.6750.044630.10443.075
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump22.087.0062.2561.2150.029690.22693.296
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0.053454.3841.4580.071430.090250.063222.762
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim)7.2239.5432.6743.1540.045680.18583.505
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum1 (sim) 8.2492.2852.6180.031660.12553.208
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum20.59318.2782.3752.530.02660.14273.222
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases0.34978.934.221.2490.02670.12313.333
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger0.38278.1012.5532.0070.033940.14433.388
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff0.6868.0062.4911.9520.029430.14963.403
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer0.46879.0192.4993.1280.029950.12853.252
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)0.54168.6162.2853.0160.025940.11173.197
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine0.47149.2933.0862.7240.03460.14473.322
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter0.55748.6812.5242.9140.02960.1933.04
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine3.3710.893.2373.7270.050.20883.691
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine11.31711.023.4373.9910.045720.17643.388
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine20.585810.643.2943.8060.036510.16323.357
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine31.08710.573.293.5980.043170.18153.481
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve0.29598.0252.3652.4920.020990.11553.052
ThermoSysPro.Examples.SimpleExamples.TestTank2.7099.1192.443.160.030350.12883.379
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve (sim)0.77139.1082.5033.2030.039270.13543.248
ThermoSysPro.Examples.SimpleExamples.TestVolumes4.9959.6022.6092.8920.049420.85913.223
ThermoSysPro.Examples.SimpleExamples.TestVolumes15.3179.2332.6312.8070.051390.56993.192
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim) 8.7052.5572.6790.045740.29393.15
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 9.4222.6652.6180.084780.78643.29

Offline version