Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 75/83 succeeded

Total time taken: 534.9

OpenModelica Version: v1.11.0-dev.94+g895a1e1

Test started: 2016-09-30 06:29:09

Tested Library: ThermoSysPro 3.1( revision 3.1+OSR-10-g335e431 )

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("-d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection,execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50230.110916.561.162.5167.80721.1
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim)364.3111.416.7964.122.5857.10220.86
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0.084616.5283.6190.085230.14690.07312.758
ThermoSysPro.Examples.SimpleExamples.TestBend0.19599.942.993.7010.026980.11523.128
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump (sim) 8.2332.91.4950.17830.13163.547
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10.35327.9322.5751.7730.064570.17933.358
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump100.535510.282.9243.5690.030120.69423.085
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump11 (sim)0.63249.1732.9452.830.034760.17883.205
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)1.1227.2332.1571.6650.051340.11053.268
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump130.48726.7632.3761.2530.026750.10993.016
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump21.6638.9812.5232.6930.034160.14293.607
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)4.3437.2272.2391.5870.040120.14873.232
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump43.5527.1062.3141.3240.039530.17843.268
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump51.4917.5952.3951.3280.032380.48363.374
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump61.5739.5062.4493.1060.034730.15033.786
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 9.4762.652.7670.080520.39353.605
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim)0.25647.2192.2761.3180.029080.26613.35
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim)0.16757.4542.3711.2520.033410.2223.619
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0.10515.581.7420.075540.076020.060453.644
ThermoSysPro.Examples.SimpleExamples.TestCheckValve3.64811.312.613.5760.043091.0154.082
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0.11498.8523.4371.3730.034830.16043.868
ThermoSysPro.Examples.SimpleExamples.TestControlValve0.19449.2362.7152.8710.026810.11183.532
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm0.20069.2272.4312.960.061090.16383.66
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim) 7.6522.4571.2850.02920.22243.679
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim) 7.482.5411.3860.045950.11613.413
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim)115.59.8242.93.1920.052270.15963.546
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve1.4619.3232.8672.8740.02420.12193.454
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum10.1418.843.8636.480.33891.4616.717
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum110.6916.383.9335.5720.31491.0075.698
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe2.6489.6842.9831.8620.120.65034.09
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim)6.2339.0932.4953.0460.037230.15333.381
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe3.5815.43.7274.1450.70741.1285.709
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim)35.2937.125.93618.920.89812.2349.145
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger1.7318.6562.6791.6340.064860.24644.051
ThermoSysPro.Examples.SimpleExamples.TestFan3.566.3153.0230.13070.08380.12642.975
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions0.22395.6842.470.23020.018980.065382.919
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes0.88756.4792.6440.36690.034770.11783.336
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes10.32175.7812.7170.082640.027080.079872.942
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve23.319.5012.5213.2840.053630.20393.459
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve0.79498.7722.4372.9520.028980.11753.258
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0.1258.242.5432.5230.018930.094643.08
ThermoSysPro.Examples.SimpleExamples.TestJunctions0.75799.2082.4192.810.03510.15783.806
ThermoSysPro.Examples.SimpleExamples.TestJunctions21.1959.7192.4343.1870.046960.56343.506
ThermoSysPro.Examples.SimpleExamples.TestJunctions34.7449.3292.6273.1470.040130.30943.366
ThermoSysPro.Examples.SimpleExamples.TestJunctions40.429810.092.3354.0740.025380.44653.233
ThermoSysPro.Examples.SimpleExamples.TestJunctions54.2589.2842.5422.9460.046880.33933.429
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker0.47886.7462.21.340.023120.11393.089
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe4.1629.1362.6062.9870.036440.1543.375
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier0.27466.3762.2241.1630.02280.13372.852
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim)2.0719.8342.3673.6580.039340.29093.499
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim)2.588.8772.5052.6410.042720.39343.314
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim) 9.8052.5163.0240.063370.64023.584
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss0.18828.1552.2652.510.021110.09843.28
ThermoSysPro.Examples.SimpleExamples.TestRefP0.24227.3512.4891.4640.02370.11353.28
ThermoSysPro.Examples.SimpleExamples.TestSensors0.35529.1042.3253.2110.030640.12273.438
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases0.39678.9374.0781.3290.02420.11723.408
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser0.72638.1352.5632.120.027280.19343.253
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss0.18427.9672.2272.610.02220.12823.003
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim)1.5066.7442.231.2450.03960.23223.017
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump10.16478.4342.4322.7320.02780.12243.144
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump21.7766.5912.1631.2460.027930.11293.061
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0.054634.4581.4860.070350.07530.060532.788
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim)6.8229.5122.6812.9820.041090.18043.647
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum1 (sim) 9.3512.2033.120.039490.15353.864
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum20.59028.4312.5052.8040.025760.11542.999
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases0.42218.8824.0771.360.039490.11433.31
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger0.4118.0932.5722.2120.029460.1513.15
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff0.59197.5722.5151.5050.045140.15133.374
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer0.47369.7152.6773.6680.027350.12453.237
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)0.57928.3722.3132.6710.025360.12643.259
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine0.47559.6163.2072.6250.029540.15283.621
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter0.52848.6322.4492.7020.026120.12823.346
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine3.20411.153.1763.5830.045550.30354.057
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine11.34610.773.1784.0030.040930.16543.406
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine20.790110.443.1623.7770.035270.15473.334
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine31.06610.763.2463.9260.039340.19643.376
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve0.25087.9622.4592.4480.021410.10022.959
ThermoSysPro.Examples.SimpleExamples.TestTank2.5029.5392.5553.3690.033070.23133.37
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve (sim)0.75939.1612.6633.2770.029470.13173.081
ThermoSysPro.Examples.SimpleExamples.TestVolumes5.26410.032.7742.9070.049381.0883.236
ThermoSysPro.Examples.SimpleExamples.TestVolumes17.6738.9962.4922.9150.047350.2313.331
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim) 9.6812.5332.7320.046031.2293.161
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 9.4412.7353.0380.072530.3343.281

Offline version