Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 78/83 succeeded

Total time taken: 535.3

OpenModelica Version: v1.11.0-dev.84+g4434dd5

Test started: 2016-09-21 06:36:01

Tested Library: ThermoSysPro 3.1( revision 3.1+OSR-10-g335e431 )

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("-d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection,execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50235.1104.617.1556.012.4877.3521.58
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim)321.7111.316.7962.322.4037.72422.09
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0.1087.1673.9160.087950.023870.10373.24
ThermoSysPro.Examples.SimpleExamples.TestBend0.1848.9172.483.2590.022980.10653.066
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump (sim) 7.3162.3931.2390.21490.12443.362
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10.36967.6942.631.540.041620.20343.296
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump100.46378.8312.5832.8110.03160.14233.282
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump11 (sim)0.49348.9222.9352.6570.029270.14263.178
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)1.2466.862.5561.1650.025670.11013.024
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump130.57.0912.5071.2270.034390.23843.104
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump21.579.4612.7993.270.034950.14563.23
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)4.1587.4812.5731.3170.041210.29763.272
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump43.8957.7232.4581.3540.042720.30833.639
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump51.4777.8562.2651.320.03350.98523.271
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump61.7129.8642.6093.420.033510.1983.625
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 9.4332.5942.8120.054340.33273.659
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim)0.24637.3432.4651.2680.030840.1213.479
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim)0.40927.1442.5571.2420.029210.12293.216
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0.10195.2951.5180.080010.080090.0673.573
ThermoSysPro.Examples.SimpleExamples.TestCheckValve3.77110.112.6733.6430.044220.18873.587
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0.08579.0133.2912.040.03110.15323.518
ThermoSysPro.Examples.SimpleExamples.TestControlValve0.24359.1282.7122.970.022160.19373.249
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm0.31249.2482.4532.9540.025650.29973.559
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim)4.7637.6022.3331.3810.028850.28483.595
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim) 7.6622.5511.5470.028890.11713.44
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim)120.29.42.7182.9140.046610.17763.562
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve1.4658.9132.6152.8310.028070.12443.342
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum10.5118.64.046.7450.3251.2366.29
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum110.5118.294.1595.7890.35972.0955.911
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe2.56811.62.8912.2210.13742.2414.129
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim)6.1868.5462.5922.5380.035420.14593.255
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe3.88316.383.9394.4720.29621.7965.904
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim)33.836.355.78517.281.3292.439.543
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger1.7038.8552.781.7770.066660.26793.982
ThermoSysPro.Examples.SimpleExamples.TestFan4.1896.2142.7840.14320.037620.11043.158
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions0.2055.7142.3990.20990.020650.084983.022
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes0.94596.5132.7390.2620.03620.12963.368
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes10.30595.7722.7440.083760.021720.074062.869
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve23.679.9272.5473.1320.050070.59833.621
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve0.78698.9372.383.3190.025450.12233.112
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0.14247.9242.3612.4320.021810.10733.023
ThermoSysPro.Examples.SimpleExamples.TestJunctions0.77358.8612.3333.0850.035230.15413.273
ThermoSysPro.Examples.SimpleExamples.TestJunctions21.2049.5722.6033.4110.049080.19393.338
ThermoSysPro.Examples.SimpleExamples.TestJunctions34.5869.7622.4933.3510.043310.22263.69
ThermoSysPro.Examples.SimpleExamples.TestJunctions40.43659.972.3693.6360.025460.92293.036
ThermoSysPro.Examples.SimpleExamples.TestJunctions53.9799.6842.5223.0170.044460.77813.343
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker0.38686.3732.0841.1590.02560.11343.014
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe4.0459.432.4083.3250.03570.22733.451
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier0.27386.862.3521.1410.020480.097743.269
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim)29.7722.5143.7320.040490.19173.312
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim)3.7858.4742.4032.6270.03960.16843.257
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim)12.9710.972.6333.1780.058221.0244.101
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss0.19499.6462.4772.6790.040930.11654.373
ThermoSysPro.Examples.SimpleExamples.TestRefP0.2438.4532.6251.4390.050270.10814.289
ThermoSysPro.Examples.SimpleExamples.TestSensors0.30349.8682.5853.6250.026930.1233.535
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases0.397510.734.5561.8540.022930.1144.206
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser0.7379.0162.5932.1290.040780.13914.161
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss0.17799.232.6152.530.046270.099763.997
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim)1.2618.622.3771.5170.026970.32744.403
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump10.20069.7152.4243.7360.022320.10783.446
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump22.0657.7152.2771.2940.027450.12184.064
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0.055514.831.6470.06960.074470.058013.002
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser6.989.5782.6223.2390.042920.20373.49
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum10.57468.6322.453.0640.028280.13722.972
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum20.7419.7352.2033.1840.039240.12064.229
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases0.349110.54.4981.5060.035160.11214.38
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger0.65299.6982.8642.2580.032340.21524.349
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff0.62499.4382.9722.2190.038760.20324.028
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer0.52899.1752.4252.5850.026890.12884.029
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)0.57839.6432.2323.4550.027470.13133.843
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine0.518110.273.3612.8620.032910.14753.888
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter0.58389.5342.8022.9480.037720.13613.655
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine3.65212.233.44.1070.051120.42224.282
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine11.92712.083.6223.9810.047050.17764.275
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine20.62110.683.1663.5350.031760.1683.796
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine31.27211.33.5093.5270.043410.19864.052
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve0.24758.7892.5982.7460.020930.13233.313
ThermoSysPro.Examples.SimpleExamples.TestTank2.7879.5372.5512.9760.029580.29063.71
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve (sim)0.849.4292.6483.1380.035580.14833.479
ThermoSysPro.Examples.SimpleExamples.TestVolumes5.1069.6672.6172.8630.047150.59263.567
ThermoSysPro.Examples.SimpleExamples.TestVolumes15.819.4892.5322.930.044180.56253.439
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim) 9.1742.4723.2920.054860.19133.184
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 9.7292.643.0750.072660.6773.285