Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 68/83 succeeded

Total time taken: 739.3

OpenModelica Version: v1.10.0-dev.617+ga1a5408

Test started: 2016-06-09 06:22:50

Tested Library: ThermoSysPro 3.1( revision 3.1+OSR-4-g51e7ea2 )

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("-d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection,execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 (sim) 79.5516.2530.453.1718.27321.43
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim) 77.8115.9428.963.5028.12521.31
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0.071766.9673.8640.082430.01470.15972.865
ThermoSysPro.Examples.SimpleExamples.TestBend0.24098.1122.3192.6640.13060.10832.914
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump (sim) 7.3662.2961.4210.042830.14983.476
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10.36567.7042.3431.6520.039190.15593.532
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump100.494210.253.0263.8570.15560.1283.107
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump11 (sim)0.54789.3612.6843.4740.03140.18083.013
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)1.2277.1192.1551.3470.045280.14313.466
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump130.53147.1772.3011.3760.026910.13273.411
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump21.3669.1582.6613.1520.090060.15473.129
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)4.4117.3822.2421.7050.041860.16523.25
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump43.4117.1712.3481.3480.044240.15983.293
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump51.3966.9772.211.3420.034890.27073.142
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump61.7059.4842.5783.2620.082180.15053.43
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 9.8032.463.4370.15930.18643.578
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim)0.25547.0212.1231.4840.031390.11143.294
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim)0.21296.6852.141.490.031160.1272.916
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0.070084.7441.6740.1620.10350.057792.766
ThermoSysPro.Examples.SimpleExamples.TestCheckValve3.3610.482.6023.0580.19050.2264.424
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0.085668.0822.7571.370.031860.33453.608
ThermoSysPro.Examples.SimpleExamples.TestControlValve0.17549.0822.3863.4250.22630.12062.942
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm0.18558.2052.3282.7870.1180.10972.883
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim)4.2336.9082.2611.5240.029230.2082.905
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim)5.1496.8622.3141.5560.031920.11532.872
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim)80.168.9282.5692.8420.14190.1673.265
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve1.2828.9632.5123.1590.070390.10183.142
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum (sim) 16.573.5866.1170.3141.0045.57
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum1 (sim) 16.733.765.8030.59580.97935.606
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe2.7359.7872.9382.0840.2680.48164.034
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim) 8.842.3733.2320.13170.16372.975
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe3.88915.553.9014.5950.46470.84155.767
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim) 43.225.46525.670.68272.6318.799
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger1.6669.4122.9051.8760.27120.27844.1
ThermoSysPro.Examples.SimpleExamples.TestFan3.5585.9052.5840.13680.03340.11433.078
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions0.19015.6432.5230.072420.019210.065142.983
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes0.9687.0512.9380.25260.03520.21993.626
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes10.3255.8062.6730.085320.021350.10062.968
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve23.4610.392.7363.7830.1910.24733.45
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve0.78939.7052.8073.4560.1210.17223.169
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0.12758.912.383.1560.075370.09963.22
ThermoSysPro.Examples.SimpleExamples.TestJunctions0.75469.0872.2783.2250.12490.13593.342
ThermoSysPro.Examples.SimpleExamples.TestJunctions21.1179.1222.6012.8490.18550.17483.334
ThermoSysPro.Examples.SimpleExamples.TestJunctions34.7269.5322.5223.3370.1970.16033.347
ThermoSysPro.Examples.SimpleExamples.TestJunctions40.391110.012.4384.5420.076210.12252.855
ThermoSysPro.Examples.SimpleExamples.TestJunctions54.1479.0122.312.8790.31950.32873.194
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker0.36576.592.1371.3830.024470.15322.913
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe3.9259.4462.3763.2480.12530.13063.585
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier0.27376.4622.1861.2950.023420.11042.882
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim)2.06210.52.6864.5430.039750.16143.084
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim)3.4758.6622.3443.0190.041290.16893.115
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim) 9.5942.6333.2730.061420.25693.391
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss0.17838.9242.4033.1560.11480.094283.176
ThermoSysPro.Examples.SimpleExamples.TestRefP0.29297.2512.3541.3650.072120.22013.258
ThermoSysPro.Examples.SimpleExamples.TestSensors0.3168.9722.4032.8380.17690.12463.449
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases0.40319.5354.2641.2680.025640.6623.335
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser0.71558.192.6262.150.29790.16752.989
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss0.16729.3662.5053.7770.11840.10222.884
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim) 6.992.1251.7590.038030.1093.009
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump10.21938.7072.3053.1620.12720.1313.001
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump21.8866.5052.011.2840.028710.1113.091
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0.05914.4191.5270.082040.10680.064732.659
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim) 9.4612.5373.0370.086730.16963.649
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum10.75638.3282.3632.6320.025960.1093.217
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum20.63488.4912.2692.7090.027550.1163.389
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases0.38268.9983.9591.220.025150.64853.167
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger0.40947.9952.681.5640.22860.32473.231
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff0.65437.3082.4011.3910.12490.44542.965
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer0.47688.6042.3782.9270.082720.20223.037
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)0.56329.1082.3023.30.02610.19213.308
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine0.46199.273.012.4310.077170.23743.546
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter0.55628.9472.5553.2390.075850.12412.975
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine (sim) 10.863.054.0950.091710.29633.345
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine1 (sim) 10.512.9333.9990.093360.17133.339
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine20.781311.032.8174.1950.082050.68183.27
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine31.18110.282.7573.6320.2690.17863.475
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve0.26588.5412.3122.7990.11780.09813.235
ThermoSysPro.Examples.SimpleExamples.TestTank1.7489.212.2623.2770.12420.12233.443
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve (sim)0.79438.7082.2483.0480.17220.1853.075
ThermoSysPro.Examples.SimpleExamples.TestVolumes5.0169.5672.7393.4660.27790.17622.927
ThermoSysPro.Examples.SimpleExamples.TestVolumes15.5689.2162.4643.2590.27250.18253.057
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim) 8.9272.333.1410.22660.18153.066
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 9.0262.4323.1430.15650.19233.122

Offline version