Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 68/83 succeeded

Total time taken: 739.5

OpenModelica Version: v1.10.0-dev.600+g2dbc14b

Test started: 2016-06-05 06:22:58

Tested Library: ThermoSysPro 3.1( revision 3.1+OSR-4-g51e7ea2 )

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("-d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection,execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 (sim) 80.3116.330.742.9378.38421.96
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim) 78.2516.4529.263.1428.46820.94
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0.086036.3663.4090.082840.015230.068352.809
ThermoSysPro.Examples.SimpleExamples.TestBend0.20489.782.8583.7320.12050.11272.981
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump (sim) 7.6672.3671.6720.045870.13383.469
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10.48.0872.5051.6250.040050.14873.788
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump100.509510.273.2053.8070.12560.13483.012
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump11 (sim)0.49829.5142.9353.3450.035140.13853.081
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)1.2567.22.3961.2350.029030.11083.452
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump130.52197.0862.1751.330.025680.10183.47
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump21.2988.8722.5052.9370.11460.18423.153
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)4.3377.7082.262.0940.04030.20453.131
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump43.2567.2372.2791.5750.041650.16993.193
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump51.3917.3562.2331.5410.046450.12023.456
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump61.5139.3622.5293.0520.12840.17293.498
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 9.3622.6133.0780.20330.18823.299
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim)0.26086.8192.1621.5150.031930.11573.014
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim)0.27297.1152.1171.8940.028550.1272.97
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0.066154.5621.5810.089350.16970.055222.687
ThermoSysPro.Examples.SimpleExamples.TestCheckValve3.38110.212.5183.260.2490.1824.02
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0.11467.9152.8151.5310.030210.14693.432
ThermoSysPro.Examples.SimpleExamples.TestControlValve0.19369.5962.8633.4810.11860.097093.058
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm0.17969.2452.6033.410.11330.096813.043
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim)4.4657.1262.4231.5270.029090.11173.054
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim)5.586.8592.2911.5230.029850.11082.924
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim)81.669.4482.6632.8660.16790.29493.496
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve1.3078.6382.3053.0030.130.10563.114
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum (sim) 16.823.6616.190.29531.1435.717
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum1 (sim) 18.293.7786.6340.36171.6015.936
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe3.0049.9142.9992.3730.21610.38243.962
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim) 8.8762.3923.050.12780.14273.183
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe4.01315.413.74.3640.35670.88126.128
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim) 44.55.52926.660.70352.2339.386
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger2.2359.2592.8671.8340.26190.26314.053
ThermoSysPro.Examples.SimpleExamples.TestFan3.6646.0942.6810.14510.031290.11313.146
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions0.22535.5082.50.071270.018850.14512.794
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes0.9856.933.1260.18040.034250.12323.486
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes10.31585.7512.7140.089160.020230.067522.891
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve24.3810.212.7143.8130.31280.19963.315
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve0.78948.5842.4063.0040.11450.11042.97
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0.1188.4472.3832.9550.065610.086992.975
ThermoSysPro.Examples.SimpleExamples.TestJunctions0.79539.1642.4333.170.13820.15833.297
ThermoSysPro.Examples.SimpleExamples.TestJunctions21.1689.4652.4583.2170.18810.17833.447
ThermoSysPro.Examples.SimpleExamples.TestJunctions34.769.4182.5823.2540.18340.15633.263
ThermoSysPro.Examples.SimpleExamples.TestJunctions40.38789.882.2284.6110.083860.11512.874
ThermoSysPro.Examples.SimpleExamples.TestJunctions54.0029.3932.6022.9250.30910.21073.369
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker0.38116.5282.1851.4050.023450.10792.827
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe3.8249.2182.4352.8860.13320.13853.648
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier0.29657.3072.1721.6970.021490.093913.353
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim)1.95910.082.5814.2220.038850.15943.101
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim)3.5568.3572.3242.6530.043330.18753.167
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim) 9.0442.4592.8870.061490.24683.41
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss0.20428.3932.2263.0170.11490.094072.962
ThermoSysPro.Examples.SimpleExamples.TestRefP0.24317.922.3951.3790.075110.67183.419
ThermoSysPro.Examples.SimpleExamples.TestSensors0.29969.8742.283.7290.12030.11763.649
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases0.42239.4314.3331.3050.028870.32143.46
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser0.73067.5572.4571.5030.33790.16223.119
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss0.17138.812.4993.0750.13290.10113.026
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim) 6.3162.1021.2520.02590.10622.849
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump10.1788.7972.3083.2590.12050.10273.028
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump22.0097.1742.0821.9620.033310.11952.998
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0.063814.5841.4470.07020.10980.056372.919
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim) 9.5762.5613.1160.15790.21753.544
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum10.53158.5662.2612.8590.032110.14753.286
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum20.76918.7412.1263.3430.02830.11073.151
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases0.33049.2013.9571.8780.026690.1233.246
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger0.40728.1092.4311.5740.23490.69023.203
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff0.6997.1652.3541.3730.25830.12743.071
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer0.6018.3942.2982.6250.078190.1233.292
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)0.5118.6952.2633.0560.026140.1043.268
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine0.43799.4022.792.8880.078290.13183.534
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter0.61258.9942.5283.3150.073390.1182.983
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine (sim) 10.513.0623.630.09230.29043.45
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine1 (sim) 10.522.7774.1930.088330.16023.318
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine20.738110.452.9563.8560.082810.14983.428
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine31.05310.462.8433.6010.25720.19193.586
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve0.22839.4412.4583.380.11510.093383.414
ThermoSysPro.Examples.SimpleExamples.TestTank1.6899.432.4773.3060.13140.15783.378
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve (sim)0.80918.4772.252.8850.17940.14573.039
ThermoSysPro.Examples.SimpleExamples.TestVolumes5.079.5522.513.3720.27340.26853.149
ThermoSysPro.Examples.SimpleExamples.TestVolumes15.4448.9162.5512.7860.28430.19193.126
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim) 9.172.3173.3770.24390.19153.061
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 9.1962.5133.1580.16830.20043.176