Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 68/83 succeeded

Total time taken: 738.8

OpenModelica Version: v1.10.0-dev.572+gcde23af

Test started: 2016-05-29 06:24:12

Tested Library: ThermoSysPro 3.1( revision 3.1+OSR-4-g51e7ea2 )

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("-d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection,execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 (sim) 80.0416.2930.393.3868.1521.85
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim) 78.9515.9929.722.7749.55620.94
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0.070516.8443.5910.097320.015220.26062.898
ThermoSysPro.Examples.SimpleExamples.TestBend0.20179.1572.3293.480.14230.10183.124
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump (sim) 8.1422.6791.6420.041830.39953.399
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10.53957.7782.5521.4790.041870.14713.579
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump100.56079.7682.9983.3590.2110.12623.095
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump11 (sim)0.49589.7022.9333.4640.031140.12523.195
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)1.1127.4352.181.5650.032470.11853.573
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump130.5027.5082.4671.280.026610.213.542
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump21.4228.9142.3753.1390.083840.14663.187
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)4.3367.5432.2842.0090.04160.16573.573
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump43.77.552.31.4770.056930.23793.51
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump51.3917.4022.2031.5850.049420.12863.517
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump61.6969.6992.6483.3750.1970.1433.354
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 10.172.623.4220.15110.19643.804
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim)0.30946.9182.2841.3420.034350.11213.17
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim)0.18827.2312.5181.3730.030290.11273.213
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0.069074.7421.5840.073120.11350.060322.943
ThermoSysPro.Examples.SimpleExamples.TestCheckValve3.66910.162.6333.0820.22070.19864.046
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0.084337.9232.7121.4370.032380.24913.513
ThermoSysPro.Examples.SimpleExamples.TestControlValve0.17899.1482.763.1840.11770.19012.924
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm0.20459.2122.5123.2820.11340.093243.23
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim)4.5557.4392.5471.4970.032560.12223.264
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim)5.4977.1612.4311.4520.032210.12373.142
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim)78.059.2732.6772.9490.14350.16743.355
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve1.3948.8622.433.1760.068890.099963.105
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum (sim) 16.123.6095.690.48021.0525.443
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum1 (sim) 16.923.995.8150.38451.0475.705
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe2.799.8062.8152.3710.20580.46793.973
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim) 8.8942.4443.1740.1420.15163.014
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe3.86615.623.6324.8460.4141.0835.672
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim) 44.515.824260.69362.8829.138
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger1.7219.5242.8341.8740.32940.46414.053
ThermoSysPro.Examples.SimpleExamples.TestFan3.54462.6930.14570.029290.10943.042
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions0.19375.2742.4310.074550.019920.083712.703
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes0.90636.9052.8520.23990.035970.12113.675
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes10.34616.082.7450.11140.024550.087473.162
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve24.129.6112.6513.150.18830.23733.403
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve0.85879.0642.5733.1710.11880.10643.113
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0.14698.0453.1972.650.06890.097263.002
ThermoSysPro.Examples.SimpleExamples.TestJunctions0.77368.5812.2222.7110.13820.1693.361
ThermoSysPro.Examples.SimpleExamples.TestJunctions21.1139.7312.3743.3070.22330.1933.655
ThermoSysPro.Examples.SimpleExamples.TestJunctions34.539.2742.4393.1330.22030.15753.344
ThermoSysPro.Examples.SimpleExamples.TestJunctions40.39159.7692.314.2760.078710.11763.007
ThermoSysPro.Examples.SimpleExamples.TestJunctions53.8989.6332.4083.3860.27130.28393.302
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker0.37916.2112.0451.20.02150.095072.868
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe3.9239.5542.5453.4720.13060.1873.247
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier0.27136.5712.091.3160.024530.097843.062
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim)1.9469.7842.4344.0460.039530.16953.114
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim)3.5828.782.3113.2640.042870.16183.026
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim) 9.2722.363.1520.062660.25153.474
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss0.21858.4352.2333.0620.11110.089922.958
ThermoSysPro.Examples.SimpleExamples.TestRefP0.20277.412.2341.2870.076210.70513.127
ThermoSysPro.Examples.SimpleExamples.TestSensors0.30849.0532.282.7620.13570.15153.742
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases0.40699.0334.1691.3640.025540.28683.207
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser0.70528.3682.6821.6130.80030.16443.128
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss0.18058.9732.3343.2470.17410.10183.148
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim) 6.6792.0171.4730.028810.10363.076
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump10.20288.7332.2463.2830.12690.09872.999
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump21.8126.992.0311.9080.027550.10782.933
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0.058434.3651.4930.067910.10410.060342.661
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim) 9.7472.72.7730.089710.1754.039
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum10.55789.0962.1442.8130.028240.84613.283
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum20.62329.1512.23.5680.026860.20843.166
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases0.34779.4724.4071.8460.030660.1133.094
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger0.39747.6182.6281.4280.36050.14153.087
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff0.60127.772.5561.3880.13280.69943.015
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer0.50128.2622.3692.6490.074720.11943.069
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)0.64858.3662.0992.8430.028690.11033.303
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine0.45199.5632.722.980.080890.1363.67
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter0.54339.0382.783.1480.071530.11592.943
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine (sim) 10.263.0843.5350.092330.17453.394
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine1 (sim) 10.713.084.0890.087680.15953.31
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine20.7698102.7193.7860.19480.13423.198
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine31.13110.242.9393.5710.13920.17143.444
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve0.21589.1042.1872.9660.13620.123.764
ThermoSysPro.Examples.SimpleExamples.TestTank1.9038.8912.2782.7330.12440.12243.653
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve (sim)0.73648.7632.3523.2720.16860.15442.833
ThermoSysPro.Examples.SimpleExamples.TestVolumes5.2769.3142.6043.2040.29450.2023.028
ThermoSysPro.Examples.SimpleExamples.TestVolumes15.3799.1892.6273.1140.2730.17883.015
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim) 8.9072.3233.1720.22970.18383.021
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 8.6332.5012.6770.15920.19653.118