Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 68/83 succeeded

Total time taken: 744.8

OpenModelica Version: v1.10.0-dev.436+g57cb405

Test started: 2016-04-30 06:14:13

Tested Library: ThermoSysPro 3.1( revision 3.1+OSR-4-g51e7ea2 )

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("-d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection,execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 (sim) 96.518.1129.314.1197.67437.3
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim) 94.316.5229.913.3817.4237.1
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0.14786.5133.5730.084550.016390.082742.776
ThermoSysPro.Examples.SimpleExamples.TestBend0.19179.6082.7833.5440.11810.1133.069
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump (sim) 7.7352.6591.2540.043760.18043.616
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10.3718.4572.9831.4630.041950.2923.699
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump100.57889.853.0233.2420.12720.13993.337
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump11 (sim)0.59029.1522.5233.2640.031220.13443.218
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)1.6497.3582.3831.5860.053420.13943.217
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump130.47317.5032.5211.2440.029320.19613.531
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump21.4679.7032.6843.4220.094870.17513.349
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)4.3057.5582.4341.2830.039340.16543.678
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump43.4887.5592.3551.2770.051520.14943.757
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump51.4627.4622.0771.5410.038730.16193.716
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump61.5329.6862.5513.420.095040.1693.473
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 9.6982.4193.070.14650.22513.858
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim)0.27986.9942.3181.4260.035850.12333.126
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim)0.19386.7652.3121.2570.032510.11883.095
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0.071254.591.6680.070510.11060.057052.702
ThermoSysPro.Examples.SimpleExamples.TestCheckValve3.34510.812.6993.1570.2340.32924.409
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0.11128.953.4891.4470.030390.24183.761
ThermoSysPro.Examples.SimpleExamples.TestControlValve0.20989.0912.5372.9160.11590.10313.439
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm0.2188.442.4072.6890.11750.10063.148
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim)4.1777.3242.3771.4530.10420.12833.306
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim)5.2666.8842.1371.4230.029860.11893.199
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim)75.499.8422.6193.1910.13490.20463.712
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve1.4338.4152.2433.0610.068370.11512.947
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum (sim) 19.563.8786.4440.28020.90448.067
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum1 (sim) 18.93.9045.6240.34740.94328.097
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe2.71711.623.0412.5950.19820.54495.258
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim) 9.1952.6183.0890.12770.14333.24
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe3.74716.473.5264.1320.38910.87067.58
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim) 49.685.47226.080.76972.4414.93
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger2.1389.8032.8941.7780.260.26744.624
ThermoSysPro.Examples.SimpleExamples.TestFan3.5386.982.9480.32850.03250.10353.699
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions0.19956.3622.7970.075510.024630.070793.413
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes0.88686.9042.8570.19550.035580.20913.627
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes10.2965.7692.7080.080110.020730.068462.91
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve23.369.8542.5972.9230.25440.24183.884
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve1.0099.1012.2543.1410.12450.12163.49
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0.12698.5822.5382.990.06580.090642.916
ThermoSysPro.Examples.SimpleExamples.TestJunctions0.77849.4012.5173.1250.12940.14813.501
ThermoSysPro.Examples.SimpleExamples.TestJunctions21.2679.9092.4113.2070.1990.18633.927
ThermoSysPro.Examples.SimpleExamples.TestJunctions35.0689.1932.3592.6960.18260.16383.811
ThermoSysPro.Examples.SimpleExamples.TestJunctions40.533210.12.2624.3420.078980.12593.31
ThermoSysPro.Examples.SimpleExamples.TestJunctions54.00610.012.6412.9380.28680.17883.987
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker0.37086.8361.9841.6450.024520.10283.099
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe4.1459.1132.2982.7960.16610.1533.723
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier0.26417.3412.1011.9630.02080.093283.182
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim)2.27110.822.2894.5750.040320.15813.778
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim)3.6549.6472.3253.390.045410.183.726
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim) 10.562.5433.2660.062780.23774.472
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss0.21519.0392.3343.1470.11450.099563.367
ThermoSysPro.Examples.SimpleExamples.TestRefP0.2257.6052.3311.2550.070960.50093.465
ThermoSysPro.Examples.SimpleExamples.TestSensors0.37539.1582.4243.0280.14740.11613.462
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases0.37589.5654.0761.3090.024220.31713.857
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser0.69148.4962.491.5280.24440.79693.457
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss0.15968.3892.3672.7710.12430.10893.038
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim) 7.0542.1631.6650.030580.11763.106
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump10.198.4982.3532.8950.11580.10753.048
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump22.0146.6672.1031.330.028980.1153.114
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0.068054.5351.5850.066920.11290.055822.734
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim) 10.52.4662.930.15620.19134.777
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum10.66228.9582.3362.7510.059020.12573.706
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum20.62258.4982.5782.820.028840.18933.398
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases0.3429.1334.0021.8210.024650.11133.194
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger0.38358.452.5431.6880.24650.49823.495
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff0.59558.1772.5461.420.13230.87943.218
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer0.52638.5072.3762.7330.079890.12863.209
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)0.55529.3672.2813.4130.027060.10883.555
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine0.43819.5483.0792.5520.079590.14133.72
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter0.70699.0512.6053.1350.07220.17373.085
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine (sim) 10.93.1923.6220.11660.31013.683
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine1 (sim) 10.982.8424.1290.093480.18383.75
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine20.581910.912.7073.9340.079380.76273.451
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine31.18611.392.8993.7580.78240.17653.843
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve0.29849.852.4613.2930.1160.16683.835
ThermoSysPro.Examples.SimpleExamples.TestTank1.71210.112.3843.2510.12350.13844.234
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve (sim)0.80379.7992.5813.4170.18540.27953.358
ThermoSysPro.Examples.SimpleExamples.TestVolumes7.04310.492.5923.3630.27780.69263.585
ThermoSysPro.Examples.SimpleExamples.TestVolumes15.34910.062.5953.3150.27920.19683.697
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim) 9.7842.5763.150.23510.29283.549
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 9.1332.52.7680.17030.19533.521

Offline version