Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 68/83 succeeded

Total time taken: 746.1

OpenModelica Version: v1.10.0-dev.395+gcc23004

Test started: 2016-04-25 06:31:23

Tested Library: ThermoSysPro 3.1( revision 3.1+OSR-4-g51e7ea2 )

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("-d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection,execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 (sim) 95.6916.0331.043.1118.25437.27
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim) 94.116.0828.383.5958.90937.16
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0.099586.3783.5190.081460.12280.072162.711
ThermoSysPro.Examples.SimpleExamples.TestBend0.29769.4692.8173.3670.1830.11323.01
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump (sim) 7.7162.2341.5250.095320.13483.746
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10.38557.7552.5561.610.045830.14863.552
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump100.520110.293.1363.710.13570.1593.188
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump11 (sim)0.51669.6672.9683.4420.029080.12993.118
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)1.7086.7182.1111.2470.033690.11753.247
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump130.4897.0822.311.250.029180.13163.38
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump21.2749.3082.5553.0890.10860.2473.333
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)4.1127.9782.4541.4620.047560.5653.482
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump43.5127.242.1721.4890.049620.2013.416
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump51.3737.4392.1421.4820.035630.13113.668
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump61.4719.412.4883.1520.085980.23733.47
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 9.2822.3852.8240.1480.2773.668
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim)0.25716.8752.3161.2820.030960.15983.105
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim)0.21676.9292.2871.340.069430.12163.134
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0.056164.4691.6060.07420.10370.057192.647
ThermoSysPro.Examples.SimpleExamples.TestCheckValve3.40912.373.0094.0540.23980.17844.904
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0.15038.7853.2541.3730.029730.443.707
ThermoSysPro.Examples.SimpleExamples.TestControlValve0.18739.7643.0483.5960.12250.094622.936
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm0.18059.0442.8043.2550.11760.11022.792
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim)4.0686.7792.2411.4720.031580.15722.898
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim)5.2697.0222.3221.4460.02870.12523.121
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim)78.0411.372.8413.3160.15570.16454.912
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve1.4279.6962.353.2420.066810.10363.954
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum (sim) 18.963.8436.6820.29810.91927.246
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum1 (sim) 19.144.3626.0080.34571.0097.445
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe2.83711.473.1962.2780.20360.50075.316
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim) 9.0872.4873.1430.12980.14513.209
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe4.03616.483.4034.5940.43530.96877.121
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim) 49.486.02325.290.76452.77214.65
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger1.76311.082.8762.2820.26570.31935.36
ThermoSysPro.Examples.SimpleExamples.TestFan3.6266.7792.8430.15450.029610.53693.235
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions0.23455.5582.5290.077530.029250.09392.847
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes1.0696.9312.9320.22030.039260.11133.647
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes10.29965.9292.7150.080990.021080.066693.064
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve26.049.9712.8232.8840.18770.18493.911
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve0.76299.1092.2713.2430.12350.11613.377
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0.12958.8262.373.1720.066120.097433.144
ThermoSysPro.Examples.SimpleExamples.TestJunctions0.7319.0072.3373.0440.13430.14933.363
ThermoSysPro.Examples.SimpleExamples.TestJunctions21.6629.2312.3892.7190.20720.18443.75
ThermoSysPro.Examples.SimpleExamples.TestJunctions36.3329.5052.3653.0730.18540.1763.728
ThermoSysPro.Examples.SimpleExamples.TestJunctions40.41039.942.2764.4180.079360.11763.074
ThermoSysPro.Examples.SimpleExamples.TestJunctions53.9410.082.3393.4180.26720.1743.9
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker0.34326.7762.0921.3640.022450.10043.216
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe4.2829.032.472.9730.12980.13383.346
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier0.28397.7142.0191.8760.022570.11863.725
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim)2.0210.152.2534.4630.039810.15363.262
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim)3.8129.1872.3243.1820.0460.16973.488
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim) 9.5652.4822.5870.057980.34534.114
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss0.20847.962.1642.720.12190.11272.863
ThermoSysPro.Examples.SimpleExamples.TestRefP0.21317.4792.2891.3560.084890.74353.025
ThermoSysPro.Examples.SimpleExamples.TestSensors0.31639.4952.4383.1630.11970.12753.667
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases0.49159.4544.1181.6640.023590.12533.544
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser0.72818.3122.4231.4660.22550.77213.451
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss0.17988.5022.3653.0960.11380.093982.86
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim) 6.4391.9851.3440.034820.10612.996
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump10.16618.532.3063.2190.10930.094812.822
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump21.9387.0781.9461.9140.028980.18923.026
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0.062044.4991.3010.069970.13370.17312.843
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim) 9.9262.4283.1250.10140.17814.113
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum10.52278.722.1212.9110.029540.12693.552
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum20.55728.4812.3632.7270.024850.10733.277
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases0.3489.2534.2521.7680.025070.11283.117
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger0.37978.5372.5541.5450.21281.0213.223
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff0.62797.5512.5641.3380.12960.45133.088
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer0.44998.0972.2552.590.074290.12393.075
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)0.5218.5352.1193.1280.026540.11453.169
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine0.46729.453.1752.540.073030.14233.541
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter0.55758.7062.3913.1380.072260.12123.007
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine (sim) 10.712.9153.9590.085970.18273.584
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine1 (sim) 10.462.943.8330.09030.16323.452
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine20.626210.132.9423.6470.091870.14283.322
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine31.18610.432.9053.6140.14280.17753.613
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve0.25869.3292.3453.4410.11370.10033.35
ThermoSysPro.Examples.SimpleExamples.TestTank1.7239.4772.3283.2820.12680.12723.632
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve (sim)0.76869.4112.5793.4360.1710.14053.108
ThermoSysPro.Examples.SimpleExamples.TestVolumes5.5469.2092.5712.8010.27240.17973.404
ThermoSysPro.Examples.SimpleExamples.TestVolumes15.7879.9892.3883.2440.28140.18773.909
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim) 9.6252.4963.2660.24790.17933.461
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 9.262.6082.9750.15880.1863.357

Offline version