Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 68/83 succeeded

Total time taken: 745.7

OpenModelica Version: v1.10.0-dev.363+gf198b82

Test started: 2016-04-19 19:21:58

Tested Library: ThermoSysPro 3.1( revision 3.1+OSR-4-g51e7ea2 )

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("-d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection,execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 (sim) 95.4216.3231.283.9197.50636.42
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim) 90.6415.9128.423.0887.53735.86
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0.072856.3533.3250.10010.016150.072532.858
ThermoSysPro.Examples.SimpleExamples.TestBend0.185310.013.3393.3580.11660.1543.081
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump (sim) 7.8452.6621.2950.065070.13373.708
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10.88027.982.6491.5520.068930.20453.527
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump100.49199.8532.7013.5820.12580.24363.225
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump11 (sim)0.5199.882.8743.6780.029970.13433.19
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)1.5528.2782.741.9030.029580.28533.342
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump130.55056.992.2091.1750.025180.10983.491
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump21.3239.022.5792.9170.084070.26693.194
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)4.2177.932.5111.7640.042070.24073.399
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump43.3887.6332.561.4380.04930.18353.423
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump51.3627.2482.151.3650.034480.25223.513
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump61.4829.7172.4413.1830.091090.30633.718
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 9.8922.6313.3570.15230.20613.568
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim)0.25387.332.7771.3160.030880.12353.105
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim)0.26846.8352.2491.2620.027730.14243.174
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0.053984.3351.40.075740.11150.15492.618
ThermoSysPro.Examples.SimpleExamples.TestCheckValve3.28110.652.4223.1620.19030.19444.702
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0.097198.2283.1651.4840.096330.25393.272
ThermoSysPro.Examples.SimpleExamples.TestControlValve0.21378.652.6592.7320.1670.10043.016
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm0.16688.8562.4723.2760.11180.12282.892
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim)4.1257.142.4511.460.029040.18523.041
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim)5.1196.8522.1971.4290.033260.11953.104
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim)80.569.8842.7033.3060.13550.33183.429
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve1.3238.6582.3113.1850.099240.10932.978
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum (sim) 18.823.5246.5940.28471.0077.43
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum1 (sim) 20.544.166.7110.3481.1898.154
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe2.7511.163.0262.5360.20320.41644.995
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim) 9.1412.6093.1450.12340.13843.145
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe3.63916.133.4564.1170.37090.82367.379
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim) 51.095.51227.60.9472.44714.61
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger1.72710.772.8162.580.33020.44354.625
ThermoSysPro.Examples.SimpleExamples.TestFan3.7476.6612.7590.16050.047080.1043.61
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions0.19136.0042.850.090680.021210.095042.971
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes0.97176.5922.9060.19770.079750.13673.293
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes10.33945.7012.6960.09140.026050.06792.838
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve24.489.6932.4672.9830.2950.17293.795
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve0.80249.0232.2663.1280.14860.15333.348
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0.16328.6992.43.1830.065940.093292.978
ThermoSysPro.Examples.SimpleExamples.TestJunctions0.76799.0422.3422.9240.13110.15953.51
ThermoSysPro.Examples.SimpleExamples.TestJunctions21.1419.2932.3772.8160.19450.18953.745
ThermoSysPro.Examples.SimpleExamples.TestJunctions36.49.9762.3763.3060.18650.17683.949
ThermoSysPro.Examples.SimpleExamples.TestJunctions40.36199.542.3453.8160.076410.11823.203
ThermoSysPro.Examples.SimpleExamples.TestJunctions53.75110.032.3772.8530.83620.18013.803
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker0.36096.5512.0041.4250.022410.10143.019
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe4.4128.9322.2463.0630.12760.13813.379
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier0.41686.7262.0341.3410.026530.21713.144
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim)1.95610.622.3634.5010.040640.17833.558
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim)3.4678.9812.2632.7510.058170.18783.765
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim) 9.7212.4212.7070.061670.23944.311
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss0.18058.2312.1053.0060.11750.1062.916
ThermoSysPro.Examples.SimpleExamples.TestRefP0.24737.432.1961.8030.076430.12223.252
ThermoSysPro.Examples.SimpleExamples.TestSensors0.46628.9642.383.1590.12150.10753.217
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases0.41459.6634.161.2040.69910.11083.506
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser0.80927.6122.3681.490.31210.12773.333
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss0.17049.1032.2723.4990.13450.099093.117
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim) 7.3692.1031.8590.071060.11693.24
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump10.17698.7052.2633.2360.12370.09513.007
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump22.046.6092.1071.3430.033140.10953.038
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0.067774.3371.5340.069080.10210.05912.596
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim) 9.8392.4642.8540.09170.22924.222
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum10.72298.7672.2222.7310.030610.3333.61
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum20.56968.7342.2592.7860.027490.15733.524
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases0.3419.0514.1471.5580.027760.123.219
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger0.38778.0352.4091.7140.25760.22283.453
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff0.60218.0582.5321.4710.19270.73763.17
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer0.50969.192.4792.9980.075330.15363.507
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)0.5298.9212.1493.2240.024790.10373.439
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine0.44379.8822.9763.2190.077820.14233.488
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter0.55678.9382.5343.2330.077740.12292.994
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine (sim) 10.943.0893.9930.097760.18953.588
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine1 (sim) 11.423.0933.8790.090160.74633.637
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine20.588610.332.7983.8270.080310.24883.399
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine31.06610.812.674.0150.13740.17183.847
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve0.2459.1382.413.1390.11290.09583.404
ThermoSysPro.Examples.SimpleExamples.TestTank1.7658.4832.3252.670.12740.16243.219
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve (sim)0.73628.6622.3372.850.17180.14143.182
ThermoSysPro.Examples.SimpleExamples.TestVolumes5.0459.1232.372.840.26740.18633.477
ThermoSysPro.Examples.SimpleExamples.TestVolumes15.2619.7692.6393.2080.26730.17883.496
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim) 8.82.3182.6570.23040.18543.433
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 8.7682.4772.6160.15940.18493.359

Offline version