Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 68/83 succeeded

Total time taken: 609.8

OpenModelica Version: v1.9.5-dev.2+g83309e5

Test started: 2016-03-10 07:52:26

Tested Library: ThermoSysPro 3.1( revision 3.1+OSR-4-g51e7ea2 )

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("-d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 (sim) 402.617.45333.94.0969.19937.98
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim) 404.817.59337.14.0348.63837.41
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0.067446.5243.5950.087680.018820.073682.774
ThermoSysPro.Examples.SimpleExamples.TestBend0.189710.963.1784.5670.13370.11692.985
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump (sim) 10.642.5444.830.054540.13773.101
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10.3999.5532.513.420.080720.18633.38
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump100.55416.012.8399.0730.14130.57073.411
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump110.474912.722.9956.1830.053080.14663.364
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)1.5997.5322.6081.5470.03370.12343.245
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump130.61287.292.2321.3590.071560.36873.299
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump21.42712.152.6795.8730.1090.26183.255
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)4.30312.692.2946.5490.052530.17193.651
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump43.34212.083.1855.5340.0570.19183.753
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump51.2956.9782.4891.3780.040350.13282.96
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump61.43611.812.4395.7330.090.28493.285
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 18.562.62511.880.17970.36343.555
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim)0.27487.372.1861.6790.055170.13563.38
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim)0.20666.9482.2761.4870.035240.12393.051
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0.096294.5071.6080.14180.16280.17062.472
ThermoSysPro.Examples.SimpleExamples.TestCheckValve3.28425.172.51918.20.31870.20333.955
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0.0895110.083.0153.1230.039580.20823.72
ThermoSysPro.Examples.SimpleExamples.TestControlValve0.178510.352.5074.6370.12110.10393.009
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm0.238510.122.584.450.13390.1072.869
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim)4.4399.3172.2313.7870.037250.22863.056
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim)4.9419.3682.1783.7580.037520.24073.177
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim)77.9518.512.75511.610.26610.40033.511
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve1.33410.672.5554.6270.076730.1333.343
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum (sim) 57.323.97243.860.58410.97487.954
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum1 (sim) 58.614.48244.720.62381.227.595
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe2.69342.963.19133.130.26340.6295.794
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim) 16.692.49910.470.14690.22433.38
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe3.6947.254.0934.60.64520.8527.207
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim) 180.76.182155.71.1132.69115.03
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger1.56332.672.6725.060.26950.37764.309
ThermoSysPro.Examples.SimpleExamples.TestFan7.2586.4072.8880.15570.047040.12593.219
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions0.44985.7822.5960.24490.023390.066422.874
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes2.0116.4682.6990.21810.049180.16343.396
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes10.56826.0832.740.23160.026970.16242.947
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve23.8823.392.83715.980.19810.36644.029
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve0.742811.082.3745.310.13270.12773.252
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0.1288.5062.3642.9470.075240.11493.032
ThermoSysPro.Examples.SimpleExamples.TestJunctions0.808820.132.49413.940.13960.17133.412
ThermoSysPro.Examples.SimpleExamples.TestJunctions21.25427.892.5620.880.19510.20024.072
ThermoSysPro.Examples.SimpleExamples.TestJunctions34.77322.982.7715.860.19550.37423.811
ThermoSysPro.Examples.SimpleExamples.TestJunctions40.405712.442.476.5530.081880.25033.104
ThermoSysPro.Examples.SimpleExamples.TestJunctions53.8227.772.59720.990.44970.22763.52
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker0.513710.752.0985.1910.033510.11643.338
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe3.99915.862.5139.5260.26960.27733.302
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier0.27519.3692.2963.8370.025230.22853.004
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim)1.87332.492.44926.360.04990.18023.466
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim)3.59332.612.40726.360.053790.32293.617
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim) 56.72.48249.340.077710.44294.379
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss0.16559.5712.3224.330.11690.098022.73
ThermoSysPro.Examples.SimpleExamples.TestRefP0.27168.0662.2272.6480.073130.11573.025
ThermoSysPro.Examples.SimpleExamples.TestSensors0.377112.582.5486.8540.13180.11712.957
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases0.41111.634.3444.2070.02680.11852.96
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser0.679919.832.613.390.24210.15093.492
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss0.184610.112.4514.410.1180.096913.052
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim) 9.4362.2063.9150.037610.2673.036
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump10.184210.122.3954.3850.11990.1023.144
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump22.17310.172.1044.0780.036170.23093.744
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0.21434.7241.6990.14190.15370.066062.689
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim) 29.543.11621.40.11140.24484.694
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum10.918516.022.9198.3260.036550.42494.337
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum20.79414.923.0277.7380.061110.25053.888
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases0.467615.485.9484.8240.031760.51744.185
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger0.570925.043.12817.430.34180.17993.984
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff0.655518.612.90111.640.1330.14343.823
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer0.673814.392.6927.8760.079790.12923.638
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)0.638911.492.3015.5410.033980.1243.51
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine0.427213.653.4326.4360.079230.31223.412
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter0.702513.392.6237.4490.090120.12383.127
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine (sim) 19.163.25211.830.11140.38123.604
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine1 (sim) 16.973.18510.010.099710.18463.519
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine20.525215.33.0318.8260.0880.15643.222
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine31.02923.353.17916.270.19320.19873.525
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve0.25369.612.3124.220.12140.10172.879
ThermoSysPro.Examples.SimpleExamples.TestTank1.67613.52.5267.7450.13140.13332.99
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve (sim)0.762515.362.5389.470.17360.14033.062
ThermoSysPro.Examples.SimpleExamples.TestVolumes4.91126.162.65519.350.58460.18863.401
ThermoSysPro.Examples.SimpleExamples.TestVolumes15.68925.082.53118.520.3980.20093.463
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim) 24.412.43417.940.25340.28053.527
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 13.422.617.0560.24430.18483.345