Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 68/83 succeeded

Total time taken: 629.8

OpenModelica Version: v1.9.4-dev.beta1.25+g2c85e5f

Test started: 2016-02-04 06:45:25

Tested Library: ThermoSysPro 3.1( revision 3.1+OSR-4-g51e7ea2 )

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("+d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 (sim) 420.820.53352.14.8588.74934.58
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim) 416.620347.45.0258.87935.39
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0.068726.8054.0020.089480.019730.07972.639
ThermoSysPro.Examples.SimpleExamples.TestBend0.185410.773.1654.1560.13250.12963.212
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump (sim) 10.763.0554.3440.055270.15293.182
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10.40979.5682.9262.9830.060780.37973.243
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump100.473315.653.4768.5860.13910.16913.304
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump110.51512.853.0586.2660.039260.1473.367
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)1.6717.9272.6411.6680.040390.12613.48
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump130.56887.6442.5431.5670.035440.1253.405
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump21.50912.82.9886.0240.096730.16783.554
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)4.20312.482.5926.0650.054820.16983.618
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump43.03912.612.765.7280.44450.16693.535
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump51.247.0422.2881.5790.040710.13663.023
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump61.51211.982.8455.5970.10140.15963.303
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 18.972.87212.140.19050.34073.49
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim)0.30887.2132.2451.4370.039630.15663.39
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim)0.16746.92.2951.3910.038830.17463.028
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0.058214.51.670.13910.14810.064662.503
ThermoSysPro.Examples.SimpleExamples.TestCheckValve3.40725.592.80318.420.21580.32363.846
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0.321310.013.133.0230.03410.15713.709
ThermoSysPro.Examples.SimpleExamples.TestControlValve0.39611.182.7284.5280.24420.15853.545
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm0.187510.472.7214.5050.12530.15442.989
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim)4.30110.082.3464.5760.044310.13083.009
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim)5.04110.162.3244.5540.055870.14653.104
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim)78.9519.882.74711.630.16760.35735.039
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve1.70410.562.3414.0870.086010.13293.938
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum (sim) 60.874.2347.570.69890.96727.545
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum1 (sim) 63.284.82949.170.69791.1797.451
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe2.77247.043.90636.890.30850.57545.389
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim) 18.543.155110.16350.40023.866
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe3.70950.214.21537.40.61510.84357.165
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim) 1946.4831691.3982.50314.69
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger1.67934.033.15225.680.34440.43264.452
ThermoSysPro.Examples.SimpleExamples.TestFan7.3786.3682.7480.27870.043040.12923.195
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions0.34275.9062.7810.087840.026970.069692.966
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes2.0366.8582.9560.34850.053040.15683.374
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes10.55695.6482.580.23360.029090.083732.75
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve22.7625.13.2617.240.2110.3494.109
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve0.790512.262.6076.2340.12890.11593.194
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0.11829.0632.5793.1910.073750.1773.119
ThermoSysPro.Examples.SimpleExamples.TestJunctions0.791320.992.7114.520.14470.16253.471
ThermoSysPro.Examples.SimpleExamples.TestJunctions21.20728.082.73720.90.340.18653.942
ThermoSysPro.Examples.SimpleExamples.TestJunctions34.88622.642.90915.350.20420.20544.032
ThermoSysPro.Examples.SimpleExamples.TestJunctions40.437513.542.7297.6240.081010.12643.203
ThermoSysPro.Examples.SimpleExamples.TestJunctions53.66928.462.7621.160.33050.36923.871
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker0.352111.562.5015.6560.030770.12183.275
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe4.29915.32.928.5850.15310.15483.522
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier0.30779.652.1434.30.061040.11783.083
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim)1.89833.242.63527.160.050710.19663.427
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim)3.5234.292.93727.420.054710.18923.712
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim) 56.992.73749.80.10410.47493.898
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss0.210810.262.6664.5690.1230.10362.826
ThermoSysPro.Examples.SimpleExamples.TestRefP0.20988.8612.4913.0550.079670.11473.144
ThermoSysPro.Examples.SimpleExamples.TestSensors0.409513.422.7397.1030.14030.18463.304
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases0.416812.554.5593.8680.027690.12114.002
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser0.704121.012.62814.610.35990.14793.292
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss0.24210.372.6194.5410.12630.10373.002
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim) 9.8852.3344.4260.10480.12173.022
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump10.226910.322.5964.180.26030.11493.328
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump22.23210.992.3924.3550.03870.30743.929
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0.068134.6181.6040.16090.15390.07362.653
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim) 29.933.02220.560.37840.51745.476
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum10.723815.52.8768.0460.1170.17274.337
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum20.552614.662.4588.0960.035940.13193.963
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases0.378114.985.1174.5410.030050.13725.179
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger0.477424.193.13416.820.2370.16623.879
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff0.796321.213.54513.730.13770.13893.718
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer0.505214.33.3867.3510.085140.35433.348
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)0.660712.292.5636.0480.14270.11453.443
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine0.471715.583.4237.0680.11330.13944.867
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter0.60614.413.0797.9130.12650.19993.118
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine (sim) 20.653.91812.860.10880.22013.745
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine1 (sim) 18.023.27711.050.10270.20263.414
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine20.646514.793.1267.610.09110.16153.826
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine30.959122.893.35615.290.16860.35373.739
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve0.235210.262.6894.4340.12770.10932.927
ThermoSysPro.Examples.SimpleExamples.TestTank1.61213.562.7247.1730.14390.15053.394
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve (sim)0.811815.92.8829.6060.18040.25793.004
ThermoSysPro.Examples.SimpleExamples.TestVolumes4.94926.542.84819.740.30950.30553.362
ThermoSysPro.Examples.SimpleExamples.TestVolumes15.54826.42.61919.880.29960.20443.419
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim) 24.722.62818.050.2750.2993.496
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 13.842.8077.2240.17610.21823.443

Offline version