Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 68/83 succeeded

Total time taken: 618.7

OpenModelica Version: v1.9.4-dev.733+gf701c46

Test started: 2016-01-13 06:39:18

Tested Library: ThermoSysPro 3.1( revision 3.1+OSR-4-g51e7ea2 )

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("+d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 (sim) 414.319.43347.35.0478.61633.88
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim) 410.819.55344.44.8128.57633.52
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0.081926.9493.9820.096880.019560.073942.817
ThermoSysPro.Examples.SimpleExamples.TestBend0.262911.513.5774.6870.13950.12952.999
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump (sim) 11.12.9834.7030.06980.16313.214
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10.38749.3252.8282.8180.05940.42323.221
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump100.563615.93.1399.1510.14730.28883.349
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump110.535812.763.0226.3860.036880.14463.203
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)1.7487.3292.4621.5480.036440.12793.188
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump130.54147.5122.4521.6330.034160.12423.293
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump21.47212.682.9825.8470.10360.32353.443
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)4.22812.062.3855.9380.053690.30933.397
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump43.15112.222.4675.8850.1870.17463.537
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump51.4617.3952.7461.450.043060.13183.062
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump61.60412.682.7876.1870.10410.31293.338
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 19.252.90112.060.18140.36333.762
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim)0.24927.3732.291.5210.044060.14173.4
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim)0.1626.7612.2141.3660.037410.12643.042
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0.082334.4861.5710.14520.14640.064042.585
ThermoSysPro.Examples.SimpleExamples.TestCheckValve3.67326.222.71719.020.23520.3443.928
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0.25079.5273.1122.8080.040890.15183.444
ThermoSysPro.Examples.SimpleExamples.TestControlValve0.299710.442.6154.5780.12590.10363.043
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm0.177610.372.7044.5240.12970.10532.938
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim)4.23310.012.5314.3310.038120.13063.012
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim)4.9929.9532.2874.3530.040570.13173.183
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim)73.0518.382.83111.50.16670.30353.604
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve1.40410.282.5384.3320.079520.19593.158
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum (sim) 57.634.18644.60.70570.93577.236
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum1 (sim) 59.184.68245.580.61270.95897.371
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe2.77942.673.34733.220.28210.58245.259
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim) 16.342.7289.910.14140.14183.442
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe3.59448.114.30635.590.55211.0986.583
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim) 191.26.859166.61.2432.53713.99
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger1.53634.823.09226.480.28460.44684.543
ThermoSysPro.Examples.SimpleExamples.TestFan7.2976.5032.8350.39660.039880.11343.145
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions0.34125.6712.5530.082230.026710.067582.968
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes1.9726.9942.9890.32340.05940.13233.514
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes10.47396.2342.6780.088990.25640.10123.135
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve22.6324.743.00117.530.20680.20383.824
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve0.743612.742.6846.5330.13310.11853.299
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0.13128.9432.4673.3640.072340.090812.972
ThermoSysPro.Examples.SimpleExamples.TestJunctions0.836121.552.83414.880.1390.15183.565
ThermoSysPro.Examples.SimpleExamples.TestJunctions21.07828.172.66221.010.34370.18383.996
ThermoSysPro.Examples.SimpleExamples.TestJunctions34.96722.22.87815.450.19840.17913.515
ThermoSysPro.Examples.SimpleExamples.TestJunctions40.412613.182.7927.3270.080910.12732.998
ThermoSysPro.Examples.SimpleExamples.TestJunctions53.8228.32.88620.950.33130.31243.839
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker0.366511.052.325.3320.031680.13113.288
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe4.22214.512.6348.420.14570.16393.173
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier0.27769.8622.2214.3760.024660.097493.166
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim)1.96931.982.52325.770.051380.26563.392
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim)3.38834.662.53728.070.051750.23723.787
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim) 56.242.72848.890.086240.49764.099
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss0.17269.9872.6284.2160.12260.10192.942
ThermoSysPro.Examples.SimpleExamples.TestRefP0.23959.362.7223.3470.083020.13493.104
ThermoSysPro.Examples.SimpleExamples.TestSensors0.314613.582.557.3270.1420.11563.476
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases0.538712.564.5814.6010.032010.12913.28
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser0.681120.722.96114.020.28720.14193.331
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss0.189910.282.7754.3830.13050.1132.907
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim) 9.8262.324.4670.034260.11912.915
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump10.169710.162.5044.2690.1250.26863.155
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump21.77710.662.3074.680.03730.17723.483
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0.13944.8121.7510.13570.14710.061872.747
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim) 30.283.02921.560.26510.1855.258
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum10.600215.52.7888.1280.041010.16914.434
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum20.705814.942.438.1890.096940.14724.118
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases0.523114.345.0135.1070.03420.13484.105
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger0.367626.113.48318.040.36050.224.071
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff0.605120.033.15312.790.2560.27793.695
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer0.574115.53.2828.3430.19560.13753.659
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)0.5521132.5536.470.19080.18783.623
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine0.520614.023.2096.6580.095960.31543.798
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter0.549813.913.4747.8450.079950.122.942
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine (sim) 20.774.01512.80.10320.21353.663
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine1 (sim) 18.533.38711.250.10180.17743.636
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine20.519415.093.2578.4670.091960.1613.247
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine31.03923.043.15816.120.14340.1723.47
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve0.297610.42.5344.3660.17880.12053.276
ThermoSysPro.Examples.SimpleExamples.TestTank1.6512.82.7746.8540.13450.12432.948
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve (sim)0.813316.32.7919.8930.18990.50982.939
ThermoSysPro.Examples.SimpleExamples.TestVolumes4.94326.882.8120.120.29860.19473.479
ThermoSysPro.Examples.SimpleExamples.TestVolumes15.60726.592.88919.840.41190.19883.278
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim) 24.662.54718.160.24720.25493.471
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 13.682.8567.0410.18620.19343.433

Offline version