Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 69/83 succeeded

Total time taken: 625.7

OpenModelica Version: v1.9.4-dev.696+g51597ed

Test started: 2015-12-15 06:35:25

Tested Library: ThermoSysPro 3.1( revision 3.1+OSR-4-g51e7ea2 )

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("+d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 (sim) 412.320.33344.74.3968.18634.7
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim) 413.720.65346.34.7147.96934.22
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0.11767.0633.9970.096750.15180.12212.855
ThermoSysPro.Examples.SimpleExamples.TestBend0.184411.093.6674.0830.24610.11513.004
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump (sim) 11.863.2115.0630.053680.31313.241
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10.38529.9362.8763.4440.056390.17633.409
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump100.544417.153.479.8620.18590.2563.443
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump110.672612.573.1465.9210.037390.14643.346
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)1.5857.5492.8451.370.034360.1543.182
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump130.57037.3772.7551.3370.19480.12623.163
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump21.35412.392.9895.5910.10260.1793.68
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)4.29112.252.565.9940.058840.20133.461
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump43.18912.972.7636.4290.05440.22373.53
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump51.2797.7242.9291.3230.039730.14293.317
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump61.53213.033.0136.2460.10050.24123.46
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 19.32.84412.260.2320.23333.76
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim)0.33176.9972.5441.3120.040950.30542.859
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim)0.16697.182.4071.2750.038320.13433.354
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0.11854.5931.7790.16250.16030.06512.452
ThermoSysPro.Examples.SimpleExamples.TestCheckValve3.21226.272.7718.940.22720.33264.03
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0.213610.533.4633.1840.036210.1613.712
ThermoSysPro.Examples.SimpleExamples.TestControlValve0.308410.392.7134.2590.27520.10763.063
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm0.183710.682.8984.2070.76530.097332.739
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim)4.32810.12.5844.3120.0370.15263.038
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim)5.0829.9552.594.1210.061630.17013.103
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim)80.1918.662.96911.430.15660.38523.74
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve1.4129.9642.7074.0660.20140.10372.909
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum (sim) 57.584.36544.480.57621.0727.109
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum1 (sim) 59.135.07745.170.64421.1257.141
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe2.64444.633.70434.680.29410.6885.287
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim) 16.922.81410.460.1460.1493.365
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe3.79249.314.49736.350.6130.91766.961
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim) 191.97.649166.71.2542.33413.99
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger1.45733.273.28424.760.37290.44394.432
ThermoSysPro.Examples.SimpleExamples.TestFan7.3346.2542.8970.26930.050.11762.945
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions0.34375.7042.6760.2090.024530.066672.751
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes1.9956.8912.9650.35840.062460.13883.4
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes10.5136.1852.770.21480.03640.12363.098
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve23.0924.722.94316.980.24050.35744.225
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve0.803611.992.7665.750.13270.12663.236
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0.12188.5592.6572.7460.078270.10582.995
ThermoSysPro.Examples.SimpleExamples.TestJunctions0.742320.972.89514.170.1480.30773.471
ThermoSysPro.Examples.SimpleExamples.TestJunctions21.29628.052.95720.880.27190.21453.929
ThermoSysPro.Examples.SimpleExamples.TestJunctions34.84422.552.87115.410.41590.16793.709
ThermoSysPro.Examples.SimpleExamples.TestJunctions40.373312.872.8416.5060.21240.11773.216
ThermoSysPro.Examples.SimpleExamples.TestJunctions53.88428.762.87421.240.44440.33073.893
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker0.390811.922.386.0290.039760.15553.356
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe4.06216.112.8629.480.15730.30273.336
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier0.2889.5182.3234.10.024940.11242.984
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim)1.91832.952.68926.640.048190.22843.376
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim)4.72534.582.9427.240.056670.36933.994
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim) 57.763.09649.940.087640.46374.308
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss0.191310.12.7843.6620.73220.13992.802
ThermoSysPro.Examples.SimpleExamples.TestRefP0.21929.4982.8773.1460.13910.11413.248
ThermoSysPro.Examples.SimpleExamples.TestSensors0.300713.552.7577.2820.15360.13813.248
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases0.394112.545.0033.9480.028720.12293.472
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser0.8121.83.07314.860.28820.28883.317
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss0.197110.922.9054.5210.36140.14723.074
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim)1.2679.92.544.2650.032880.14482.98
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump10.202110.152.5913.7820.33540.19573.272
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump22.15410.652.5434.1950.037390.12783.77
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0.092654.8561.8370.16530.16240.064652.651
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim) 30.833.39622.350.12890.31674.661
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum10.550217.113.2299.2990.036020.13814.43
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum20.693515.482.8258.370.035410.12814.152
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases0.511915.275.8294.9670.028820.1194.35
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger0.360326.643.28218.60.34490.18794.252
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff0.787120.283.33912.870.13910.1893.772
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer0.49915.883.5438.620.086750.14263.511
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)0.6331132.8326.6280.035770.18643.381
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine0.430516.094.1797.9750.085560.14833.73
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter0.55214.133.1427.6280.082330.12813.179
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine (sim) 19.624.10111.790.11140.20063.569
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine1 (sim) 18.593.658110.10010.34823.506
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine20.569115.313.7147.9820.16850.24233.35
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine31.01124.43.6416.440.15560.39573.792
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve0.24929.6622.5943.830.28370.10132.877
ThermoSysPro.Examples.SimpleExamples.TestTank1.66313.582.7747.6050.18920.13952.893
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve (sim)0.899516.32.71110.260.18680.14793.016
ThermoSysPro.Examples.SimpleExamples.TestVolumes5.08727.092.85520.30.41480.18863.357
ThermoSysPro.Examples.SimpleExamples.TestVolumes15.32526.182.88319.320.31170.28463.405
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim) 25.52.68917.990.26140.48854.098
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 13.542.9286.9320.29230.18453.232

Offline version