Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 71/83 succeeded

Total time taken: 642.3

OpenModelica Version: v1.9.4-dev.545+g29c4664

Test started: 2015-11-19 06:40:30

Tested Library: ThermoSysPro 3.1( revision 3.1+OSR-4-g51e7ea2 )

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("+d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 (sim) 426.421.91357.14.5157.99534.89
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim) 426.720.94358.24.4268.54434.59
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0.085997.3774.4210.15530.042010.087272.709
ThermoSysPro.Examples.SimpleExamples.TestBend0.236812.023.3915.3270.14960.13633.05
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump31.3111.993.3455.180.059610.30193.129
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10.36249.9953.3653.0210.064760.21693.354
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump100.587516.583.3039.4690.21320.26493.357
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump110.572813.383.516.5380.047190.17323.179
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)1.7577.9122.9481.2190.034550.13233.611
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump130.53338.2632.9011.3340.037570.14533.874
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump21.58413.422.976.8080.1040.28553.3
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)4.60713.052.7386.6750.054470.17673.432
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump43.60313.22.7616.5950.057760.24883.566
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump51.7497.2852.7231.3430.052080.25632.943
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump61.83613.482.9016.6760.10310.31293.515
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 18.992.92311.890.27040.21573.72
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim)0.33787.5832.7691.3880.047050.25483.152
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim)0.17387.5582.6511.5890.044790.16383.141
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0.062454.9291.9090.25470.3090.064982.424
ThermoSysPro.Examples.SimpleExamples.TestCheckValve3.4326.412.8719.380.46090.20753.737
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0.109810.343.8062.8090.035770.21823.497
ThermoSysPro.Examples.SimpleExamples.TestControlValve0.343410.262.963.9720.27580.25672.94
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm0.175710.082.7634.0790.25690.10292.908
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim) 10.582.7014.6470.04840.2732.938
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim)5.47610.962.5614.8290.036910.51553.462
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim)232.518.842.96611.850.16570.19033.701
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve1.54910.482.7684.0620.098850.20283.369
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum (sim) 58.884.74345.170.4081.247.343
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum1 (sim) 60.564.93346.860.59681.1027.099
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe2.78345.143.77835.170.28880.57165.356
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim)6.27317.313.14610.480.15110.14483.423
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe3.6550.554.86137.310.50341.1266.778
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim) 199.37.464173.11.1812.44115.23
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger1.77535.573.82526.630.48380.28684.362
ThermoSysPro.Examples.SimpleExamples.TestFan7.5086.7373.1420.29440.040930.11863.166
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions0.37666.0022.8660.098040.1520.073382.839
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes2.0166.7052.9690.37340.04820.14423.199
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes10.58425.872.6620.2390.026220.076922.889
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve5.4924.853.01317.620.22890.20323.816
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve1.35912.213.1265.5290.14580.12783.309
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0.15528.6612.7732.6640.083310.12013.047
ThermoSysPro.Examples.SimpleExamples.TestJunctions0.768421.582.80914.710.18080.34513.587
ThermoSysPro.Examples.SimpleExamples.TestJunctions21.13128.563.06221.120.36680.19323.844
ThermoSysPro.Examples.SimpleExamples.TestJunctions34.62623.132.9916.120.23920.32713.482
ThermoSysPro.Examples.SimpleExamples.TestJunctions40.415114.212.9077.7350.084280.19053.321
ThermoSysPro.Examples.SimpleExamples.TestJunctions53.88529.412.96922.130.52730.21613.609
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker0.345911.322.7545.5070.02710.1062.952
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe4.93615.873.2128.9250.1590.28853.315
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier0.33049.9472.7424.2660.024870.10732.833
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim)2.1833.223.00726.240.047940.31353.634
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim)3.19235.113.10528.080.055820.31383.578
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim) 59.082.88551.490.084910.41674.218
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss0.176710.922.9283.9870.78760.10283.139
ThermoSysPro.Examples.SimpleExamples.TestRefP0.31219.1632.8433.040.093870.13883.192
ThermoSysPro.Examples.SimpleExamples.TestSensors0.3267152.9588.4630.14630.12013.347
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases0.409412.94.8334.6220.030370.12633.316
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser0.943322.713.11215.170.30910.34443.804
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss0.215313.123.3395.2560.24220.13364.192
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim)1.70612.683.1395.4880.05320.24063.8
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump10.179712.863.2455.5820.15840.41033.71
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump22.30113.423.2475.8710.25060.37793.929
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0.18266.3812.3170.32570.3030.077013.394
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim) 29.973.54221.580.11460.22224.555
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum10.611416.343.0229.6530.039840.1423.511
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum20.590415.643.2768.7510.033780.14763.457
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases0.450813.575.2394.0470.036190.1524.124
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger0.419222.493.10615.560.27360.25633.321
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff0.795618.173.06711.560.14590.14273.288
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer0.471413.422.9637.1890.091080.15893.049
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)0.511211.542.5375.8040.030250.12283.075
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine0.44814.783.8976.6530.1550.41563.705
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter0.525613.692.8047.650.088040.13343.049
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine (sim) 20.684.16912.550.11370.1953.678
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine1 (sim) 19.633.8711.740.13650.19663.72
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine20.580415.443.8417.8850.10470.20643.427
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine31.0624.673.78116.870.16890.19163.689
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve0.306210.562.7873.9760.13820.85672.829
ThermoSysPro.Examples.SimpleExamples.TestTank4.66914.122.7197.6960.1440.12973.464
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve (sim)0.827716.792.80210.30.19030.13933.383
ThermoSysPro.Examples.SimpleExamples.TestVolumes5.40527.883.0720.770.39130.20623.465
ThermoSysPro.Examples.SimpleExamples.TestVolumes15.43327.473.00520.440.41290.18733.446
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim)19.2125.733.05918.750.26040.26963.417
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 13.913.3626.9050.17460.19033.308

Offline version