Recursive BuildModel Test

BuildModel Results: 82/83 succeeded

Simulation Results: 71/83 succeeded

Total time taken: 943.7

OpenModelica Version: v1.9.4-dev.451+g168aff9

Test started: 2015-11-05 07:06:18

Tested Library: ThermoSysPro 3.1( revision 3.1+OSR-4-g51e7ea2 )

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("+d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 338.621.82316.8   
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim) 424.221.893545.4148.79134.17
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0.09767.1724.0050.10280.02170.20112.994
ThermoSysPro.Examples.SimpleExamples.TestBend0.172812.573.5655.4870.17510.14513.223
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump40.8911.523.0084.9720.065290.14313.357
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10.412310.022.9983.3120.073940.17763.487
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump100.540215.762.9639.0180.2140.20523.387
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump110.530913.183.7136.1940.04220.14663.109
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)1.6227.6172.741.4270.081390.26493.131
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump130.56137.7873.1371.3940.050150.12793.104
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump21.74133.0845.8990.11350.18023.755
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)4.84712.912.6166.4410.072230.18553.624
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump44.14312.042.8135.5630.066810.19993.417
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump51.8477.1532.5511.2730.049880.32062.982
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump61.60512.472.856.0050.10680.29523.25
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 19.442.96811.990.20310.50743.8
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim)0.28536.9772.4821.3060.047790.25612.913
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim)0.16817.8922.5291.2980.047720.87793.164
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0.066059.8321.8461.8253.8130.062542.428
ThermoSysPro.Examples.SimpleExamples.TestCheckValve3.25126.882.92319.850.22330.32023.58
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0.20289.8473.5242.6790.040310.17163.457
ThermoSysPro.Examples.SimpleExamples.TestControlValve0.398810.692.7434.5510.13570.10673.176
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm0.294310.532.7374.5830.1360.13382.963
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim) 10.252.5034.4670.058190.13793.109
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim)6.01210.462.6774.5960.063040.13343.013
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim)190.819.283.06712.120.30180.17733.642
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve1.9019.9222.7424.0710.099140.12122.923
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum (sim) 58.494.57245.20.77060.93827.037
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum1 (sim) 60.074.93946.320.80970.90767.242
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe2.80246.244.08135.710.520.62675.369
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim)6.44217.943.22310.950.16110.18823.458
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe3.87749.674.84336.660.77760.8066.617
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim) 204.67.583178.41.4842.4914.71
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger (sim)1.48335.083.34126.730.43180.28694.313
ThermoSysPro.Examples.SimpleExamples.TestFan7.4836.9463.2250.32050.054240.14653.228
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions0.59285.8642.7690.090740.028310.069332.944
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes2.1046.6992.7720.44430.054660.15283.313
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes10.61155.9462.8810.10150.029540.078712.881
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve5.71124.583.01217.290.23360.44533.63
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve1.24612.562.9125.9730.15380.33973.22
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0.16788.8872.7952.7930.085870.11433.126
ThermoSysPro.Examples.SimpleExamples.TestJunctions0.751221.42.85814.70.17220.30723.38
ThermoSysPro.Examples.SimpleExamples.TestJunctions21.22228.793.1821.410.35170.18833.686
ThermoSysPro.Examples.SimpleExamples.TestJunctions34.68923.52.9516.230.21140.44823.685
ThermoSysPro.Examples.SimpleExamples.TestJunctions40.500313.412.7017.3380.08730.12223.185
ThermoSysPro.Examples.SimpleExamples.TestJunctions54.06828.942.98421.590.58130.19853.627
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker0.3944122.6466.230.028740.10323.015
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe4.91115.883.0249.2260.16980.15763.333
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier0.28589.8332.5784.2610.029090.12262.868
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim)1.90933.463.00826.740.049790.17543.514
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim)3.42335.212.8828.180.055260.2013.917
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim) 59.92.94551.490.080010.26165.15
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss0.192811.352.9334.4270.7970.11823.094
ThermoSysPro.Examples.SimpleExamples.TestRefP0.23348.7512.8772.9740.089080.12722.848
ThermoSysPro.Examples.SimpleExamples.TestSensors0.506714.82.9647.4530.87140.12313.42
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases0.398412.874.6034.5820.1930.13423.396
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser0.861922.982.95315.370.31750.29814.067
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss0.260111.232.8624.8920.13410.10113.27
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim)1.42311.52.7384.9710.060550.16473.63
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump10.210112.182.8735.1690.15580.12743.878
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump21.97111.73.1425.1390.080970.12513.287
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0.0800111.041.9571.9134.0630.089693.041
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim) 28.153.20720.590.1120.19494.074
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum10.723715.372.9118.2140.044850.31033.914
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum20.854315.253.0368.0760.090820.22853.843
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases0.344712.84.7714.580.030950.11763.329
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger0.39721.142.914.030.27120.3063.655
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff0.671618.923.0711.880.18610.14813.663
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer0.463814.872.888.5390.089760.12863.256
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)0.537512.292.7726.20.033920.19353.115
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine0.47214.383.9326.5360.09160.1563.693
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter0.546414.842.978.0640.088440.12563.619
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine (sim) 20.524.01312.770.15980.19943.406
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine1 (sim) 19.213.77911.830.1240.17493.329
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine20.531316.253.8748.8030.10020.16013.352
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine31.15824.753.62616.90.17270.2933.789
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve0.328110.312.9224.4530.14840.12032.694
ThermoSysPro.Examples.SimpleExamples.TestTank4.5813.812.7597.5770.15040.13043.226
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve (sim)0.803816.352.89410.20.19730.14952.933
ThermoSysPro.Examples.SimpleExamples.TestVolumes5.38827.182.99620.130.4670.21063.4
ThermoSysPro.Examples.SimpleExamples.TestVolumes15.4727.332.84920.420.48630.20013.396
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim)18.2925.932.80119.220.27170.27713.377
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 13.53.0896.940.18520.18393.124