Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 72/83 succeeded

Total time taken: 937.7

OpenModelica Version: v1.9.4-dev.195+g5a5e52f

Test started: 2015-10-10 07:06:24

Tested Library: ThermoSysPro 3.1( revision 3.1+OSR-4-g51e7ea2 )

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("+d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 (sim) 42921.82361.45.3958.98831.43
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim) 417.720.89351.75.3858.47231.35
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0.092887.054.0610.1010.021780.078112.813
ThermoSysPro.Examples.SimpleExamples.TestBend0.228110.63.154.1990.13650.12533.03
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4.61111.393.0784.7950.060230.26543.215
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10.39269.1052.7133.0280.068350.18423.136
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump100.588816.483.329.2010.15210.34253.485
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump110.573512.733.246.0870.042510.15063.244
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)1.9538.0332.7721.5370.037410.27843.434
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump130.51148.4452.8321.2920.042070.13544.166
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump22.35314.12.9147.0940.15990.29643.661
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)7.85413.132.8556.8370.061220.21963.248
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump46.30612.892.8086.2610.064650.17863.599
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump51.9087.7232.7921.5870.049060.3053.018
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump62.81812.572.9676.0620.16890.29723.104
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 19.423.03312.410.23570.33963.425
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim)0.4287.2772.6981.3260.038270.12473.115
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim)0.22227.3392.6161.3080.040730.1263.274
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0.074210.231.761.9823.7690.07242.824
ThermoSysPro.Examples.SimpleExamples.TestCheckValve3.20726.782.89219.410.23570.2174.048
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0.0781410.893.9823.2750.036530.17173.463
ThermoSysPro.Examples.SimpleExamples.TestControlValve0.283410.542.7424.6310.13270.10792.951
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm0.163410.422.684.650.12760.098722.885
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim)9.25810.452.5924.5230.043240.13083.186
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim)8.68610.272.4984.2650.044220.12573.367
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim)36.6219.693.28312.20.19750.19293.835
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve2.80410.592.8834.5670.082830.11622.968
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum (sim) 56.94.743.80.57051.2496.599
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum1 (sim) 60.224.98546.151.0771.0756.948
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe2.84345.793.71236.150.3310.53645.078
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim)19.0717.392.77410.880.15860.15153.448
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe3.80848.674.66236.030.62280.99976.383
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim) 200.56.764176.31.2932.52513.69
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger2.42534.773.27326.190.30480.43514.59
ThermoSysPro.Examples.SimpleExamples.TestFan18.287.0773.1370.33350.048060.12283.462
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions0.49335.9652.9460.089040.028510.070682.857
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes1.9056.5873.0560.36870.057390.15022.983
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes10.50736.1772.980.24880.02990.08282.86
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve5.39725.613.1218.410.22210.20433.676
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve0.840912.442.8066.10.13770.17173.249
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0.14838.6562.9482.6410.08190.11072.9
ThermoSysPro.Examples.SimpleExamples.TestJunctions0.686121.73.08114.870.14790.16273.467
ThermoSysPro.Examples.SimpleExamples.TestJunctions21.22929.733.05322.310.28270.35133.761
ThermoSysPro.Examples.SimpleExamples.TestJunctions34.83723.53.06616.350.42510.17763.501
ThermoSysPro.Examples.SimpleExamples.TestJunctions40.466613.822.7757.3560.082030.12283.509
ThermoSysPro.Examples.SimpleExamples.TestJunctions56.06229.612.91922.330.55520.19623.635
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker0.341511.742.5226.0580.041420.10973.059
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe6.80515.522.9028.9140.16120.35343.336
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier0.2776102.4654.4680.027460.10673.02
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim)1.8633.282.80526.740.22970.24083.297
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim)4.49834.062.98427.560.086660.19633.286
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim) 58.172.88550.80.082330.37014.055
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss0.154510.192.8323.9970.25280.0973.035
ThermoSysPro.Examples.SimpleExamples.TestRefP0.23618.7173.0852.5510.087190.19422.971
ThermoSysPro.Examples.SimpleExamples.TestSensors0.416413.952.9477.5210.13660.11893.251
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases0.40212.194.8183.8220.029970.31983.231
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser0.706120.992.74813.960.3810.36773.555
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss0.169310.412.7453.950.62780.10173.004
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim)1.89510.662.7384.6260.040030.1463.166
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump10.159410.142.5734.0020.30830.099863.181
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump24.1669.7672.6174.2360.042420.13982.76
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0.387610.411.6461.8283.9460.06382.953
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim) 27.493.407190.1130.20114.798
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum10.73613.812.7867.3020.087010.16013.533
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum20.581214.572.777.9660.036130.13143.702
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases0.372214.154.5384.8210.030650.15244.685
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger0.432125.323.13916.920.29880.30174.676
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff0.753121.983.77613.770.1530.1544.155
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer0.582216.073.2698.7230.090440.20473.809
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)0.604315.23.4447.4480.033240.13284.162
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine0.469517.044.2967.4850.30090.14594.834
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter0.504815.173.3048.2740.16010.15953.295
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine (sim) 22.335.04413.050.11930.20293.943
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine1 (sim) 21.594.1512.990.31250.33053.853
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine20.670715.633.9728.0910.096760.1623.332
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine31.00925.134.0217.190.17310.33393.438
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve0.210610.012.7874.0390.27520.10892.818
ThermoSysPro.Examples.SimpleExamples.TestTank2.99113.72.8986.910.74070.13573.033
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve0.854616.142.79710.030.18920.14083.015
ThermoSysPro.Examples.SimpleExamples.TestVolumes9.24228.162.87221.340.42270.22083.325
ThermoSysPro.Examples.SimpleExamples.TestVolumes19.47727.942.87421.120.45710.19873.326
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim)39.3926.272.98519.420.28290.30343.296
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 14.153.0787.3240.20110.29723.273