Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 71/83 succeeded

Total time taken: 941.3

OpenModelica Version: v1.9.4-dev.154+g79cd7ca

Test started: 2015-10-01 07:10:44

Tested Library: ThermoSysPro 3.1( revision 3.1+OSR-4-g51e7ea2 )

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("+d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 (sim) 420.821.9353.45.1768.41331.9
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim) 42221.35355.65.5488.58730.91
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0.19427.3284.3550.098120.020690.14012.739
ThermoSysPro.Examples.SimpleExamples.TestBend0.198511.843.5065.1210.13970.11942.978
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump59.6211.53.0445.0140.056250.30823.103
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10.447310.083.3712.850.083770.47273.332
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump100.502716.283.3839.2350.21760.16843.311
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump110.558413.263.4766.4920.063750.20053.101
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)1.6888.0583.2721.4190.04980.1363.207
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump130.53297.8282.8081.5420.065090.17143.305
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump22.513.753.4196.4080.16830.33983.438
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)8.14513.272.9196.8470.078160.23183.267
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump46.06912.433.0945.580.07280.18763.541
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump52.2097.4272.7881.3150.048680.28463.016
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump62.8312.433.0485.9830.11710.18373.119
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 19.333.06812.220.19040.36853.501
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim)0.32657.0812.7891.2630.041070.13082.884
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim)0.18367.2892.8321.2470.042580.2242.966
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0.0605810.442.1162.0053.7850.20562.349
ThermoSysPro.Examples.SimpleExamples.TestCheckValve4.0126.482.91719.320.23060.35473.68
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0.170210.513.7793.0820.038750.20933.431
ThermoSysPro.Examples.SimpleExamples.TestControlValve0.177110.262.8244.1740.15250.11113.023
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm0.254410.962.7945.060.1440.10272.882
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim)9.3049.822.6484.0780.044670.12482.963
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim)9.34710.42.5244.3220.054260.24953.277
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim)37.5419.212.93712.220.17420.18973.718
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve2.80810.52.8334.5570.084030.112.942
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum (sim) 57.554.62944.540.59851.1476.655
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum1 (sim) 60.294.98646.20.72251.2537.153
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe2.88644.863.79435.350.38950.55254.803
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim)20.0317.233.10610.450.15330.16913.381
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe4.05849.784.93236.570.7231.1236.466
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim) 205.27.006178.31.5243.04215.34
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger1.60134.513.47226.120.43570.25644.254
ThermoSysPro.Examples.SimpleExamples.TestFan18.566.4132.8050.28950.053060.1213.179
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions0.46315.9432.8390.10.029620.075392.923
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes2.1376.552.850.43040.05550.1283.109
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes10.49055.9652.7060.2210.028540.077792.957
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve6.224.632.86917.230.26390.57063.716
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve0.783412.853.0066.5160.14630.33282.875
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0.13079.0472.8743.0540.080280.10442.959
ThermoSysPro.Examples.SimpleExamples.TestJunctions0.713821.653.01714.620.17260.33483.57
ThermoSysPro.Examples.SimpleExamples.TestJunctions21.15528.272.8921.330.2290.20653.645
ThermoSysPro.Examples.SimpleExamples.TestJunctions34.94123.663.36116.240.36250.17763.543
ThermoSysPro.Examples.SimpleExamples.TestJunctions40.46513.362.8727.0990.087390.1223.199
ThermoSysPro.Examples.SimpleExamples.TestJunctions56.08729.253.37121.790.43620.19413.484
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker0.348812.272.566.3470.044180.13263.252
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe7.03616.153.1359.0260.1630.1463.705
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier0.315310.572.6864.3210.027210.11743.465
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim)2.00633.692.85827.350.048440.16673.286
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim)3.72332.572.77226.090.057110.29543.374
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim) 58.193.05750.260.08920.41694.397
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss0.175410.172.9843.8890.29180.10212.931
ThermoSysPro.Examples.SimpleExamples.TestRefP0.28768.8352.8013.0680.085740.1282.935
ThermoSysPro.Examples.SimpleExamples.TestSensors0.356413.782.8717.4890.30670.10913.026
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases0.380612.585.1024.2050.028250.13933.147
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser0.666621.132.92114.160.260.5643.252
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss0.213310.593.1954.4550.14680.11942.853
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim)2.11710.452.7264.7130.038820.12392.876
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump10.172610.492.8594.3420.14380.099993.072
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump24.31610.422.5954.470.04170.12093.214
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0.0660211.411.8961.8944.1860.11873.343
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim) 30.923.43822.310.11570.25964.877
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum11.02716.43.1628.5690.073260.334.373
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum20.786815.332.9888.3680.037170.13243.833
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases0.35813.925.2474.0670.031710.13114.467
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger0.452825.623.70216.730.45930.23234.634
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff0.658821.124.18713.250.16550.16153.38
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer0.46516.883.9639.4710.092530.18643.194
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)0.640713.173.4156.3070.035550.11853.323
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine0.444515.784.2657.590.086190.14113.72
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter0.533314.773.1288.0180.088920.14993.409
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine (sim) 21.134.48412.810.12730.22663.509
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine1 (sim) 19.634.62711.410.13360.19483.309
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine20.578815.23.9938.0530.096410.15523.059
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine31.03124.493.82516.560.16750.32023.646
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve0.23210.262.8494.3710.25710.10112.705
ThermoSysPro.Examples.SimpleExamples.TestTank3.30213.393.0017.1360.16330.13762.974
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve0.828216.063.019.890.22650.14442.837
ThermoSysPro.Examples.SimpleExamples.TestVolumes9.54527.263.01520.440.4150.19333.212
ThermoSysPro.Examples.SimpleExamples.TestVolumes19.85527.732.92720.910.42950.19473.294
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim) 25.772.84419.090.28930.28933.277
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 14.483.1257.6690.21270.28853.204