Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 71/83 succeeded

Total time taken: 947.1

OpenModelica Version: v1.9.4-dev.146+gbd69748

Test started: 2015-09-30 06:49:12

Tested Library: ThermoSysPro 3.1( revision 3.1+OSR-4-g51e7ea2 )

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("+d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 (sim) 431.123.19362.25.238.34832.16
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim) 420.321.03353.25.518.36132.22
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0.081828.0294.8630.10720.045840.27522.963
ThermoSysPro.Examples.SimpleExamples.TestBend0.19612.13.3765.0460.14010.12633.436
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump59.1112.543.9155.1050.061530.1623.324
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10.459311.173.3873.6840.14280.33693.66
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump100.524317.753.56510.230.18220.5293.3
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump110.572713.762.9997.1090.041720.13873.5
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)1.758.0462.8141.5350.040430.12943.554
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump130.5577.4442.7711.5030.038240.15373.124
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump22.45313.793.0986.5230.16960.30723.72
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)7.99913.022.6556.5790.0660.18073.569
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump46.30712.822.8036.3430.11220.19843.389
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump52.1487.3412.6031.3010.049060.29083.12
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump63.17713.372.9866.3590.1120.2773.655
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 18.882.933120.19990.33653.43
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim)0.27457.4092.7271.4470.041420.13353.089
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim)0.20176.9342.5751.2730.044760.26412.803
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0.102810.131.8731.9043.9320.062932.547
ThermoSysPro.Examples.SimpleExamples.TestCheckValve4.13327.133.02219.780.24550.30313.806
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0.258610.213.7212.7510.037440.15423.569
ThermoSysPro.Examples.SimpleExamples.TestControlValve0.189911.062.8844.9890.13520.10612.967
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm0.30311.092.8074.9860.14360.1343.071
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim)9.3410.642.824.5810.047490.15483.077
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim)9.29210.512.6134.4720.041480.13013.283
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim)40.0521.83.13513.680.17220.19274.647
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve2.72711.73.0654.7860.1620.19253.52
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum (sim) 60.94.549480.67521.1096.638
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum1 (sim) 63.015.2348.140.85641.337.48
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe2.96745.84.08535.870.34120.54214.986
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim)21.3220.093.13711.580.24570.2014.974
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe3.79551.335.50937.450.86991.1276.404
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim) 206.27.381177.81.4842.86516.72
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger1.66534.273.76425.650.44340.34674.092
ThermoSysPro.Examples.SimpleExamples.TestFan18.056.1993.0160.30840.045340.11432.74
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions0.31976.3523.0910.10180.029870.089863.064
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes2.1526.552.8340.35950.055340.143.195
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes10.46646.2342.6950.16250.032290.23623.136
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve5.72325.233.13117.710.25470.42413.743
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve0.79513.052.9886.1010.14010.73783.103
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0.19138.732.7752.7630.090530.11913.041
ThermoSysPro.Examples.SimpleExamples.TestJunctions0.751421.722.83150.2150.383.432
ThermoSysPro.Examples.SimpleExamples.TestJunctions21.18829.012.87221.830.37360.19953.792
ThermoSysPro.Examples.SimpleExamples.TestJunctions34.81923.472.9516.470.40290.21683.447
ThermoSysPro.Examples.SimpleExamples.TestJunctions40.37112.782.7626.7750.087540.18233
ThermoSysPro.Examples.SimpleExamples.TestJunctions56.08628.882.90521.90.31980.24253.538
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker0.379811.372.7945.5950.028870.10752.871
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe7.14616.252.9889.130.1640.47343.524
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier0.352410.272.5154.2940.027980.10993.343
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim)1.86932.182.76225.920.051520.17413.297
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim)3.81433.232.90526.760.055250.18713.348
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim) 58.282.88550.820.089460.41774.092
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss0.170210.582.9074.0810.69460.10052.822
ThermoSysPro.Examples.SimpleExamples.TestRefP0.26679.4593.1073.1330.097510.15573.015
ThermoSysPro.Examples.SimpleExamples.TestSensors0.344214.242.9548.1480.13950.12052.904
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases0.394412.514.8024.5170.026610.12313.065
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser0.653621.43.01114.320.25050.40623.466
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss0.22379.9872.8793.9250.25560.11712.835
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim)2.25610.342.6214.560.1820.11833.027
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump10.184311.392.8985.0630.17030.11733.162
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump24.33210.382.6054.6340.04210.12533.108
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0.0666511.041.7931.964.1180.081953.156
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim) 30.023.16821.570.11320.2724.918
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum10.668716.353.4278.4130.037890.28464.231
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum20.78716.883.1899.6680.038350.16513.849
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases0.404314.145.2044.5840.030180.12274.225
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger0.424725.643.52416.810.3530.33794.641
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff0.601820.993.54413.590.14580.28453.459
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer0.539316.193.3449.1280.089760.13993.526
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)0.884612.683.0816.1990.03330.11653.28
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine0.43815.494.5046.8120.68330.16493.389
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter0.617215.182.9528.2070.089920.3453.618
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine (sim) 20.644.03612.820.11530.19373.509
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine1 (sim) 19.243.83811.760.12880.17983.365
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine20.675515.693.9928.2570.10020.20263.166
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine31.07424.443.69216.390.1750.33973.873
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve0.223510.082.7864.1760.25220.10042.786
ThermoSysPro.Examples.SimpleExamples.TestTank3.35814.022.8787.6220.15990.1443.264
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve0.795616.472.79110.170.27560.3432.92
ThermoSysPro.Examples.SimpleExamples.TestVolumes9.75827.653.09620.70.41580.18533.282
ThermoSysPro.Examples.SimpleExamples.TestVolumes19.8627.042.82120.340.43070.19873.27
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim) 262.99719.140.2890.28663.314
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 14.283.2417.4460.20140.29743.123