Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 71/83 succeeded

Total time taken: 954.2

OpenModelica Version: v1.9.4-dev.62+g0de2ae0

Test started: 2015-09-18 06:44:55

Tested Library: ThermoSysPro 3.1( revision 3.1+OSR-4-g51e7ea2 )

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("+d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 (sim) 435.522.43367.85.4048.57431.36
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim) 432.220.89365.75.7448.05531.8
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0.17386.8894.0030.0930.019810.094362.702
ThermoSysPro.Examples.SimpleExamples.TestBend0.217612.424.0625.0980.16880.12143.01
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump59.4612.193.8534.8750.057940.15423.273
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10.430610.63.4083.7970.074620.20733.142
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump100.729916.273.3969.1360.15980.2723.33
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump110.603713.573.2866.6560.050250.16373.439
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)1.7468.0223.1421.4990.039060.13093.238
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump130.72117.9553.1051.4580.040530.25083.249
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump22.51813.143.335.7390.11020.24413.761
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)8.08212.652.835.4580.92870.17433.281
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump46.13913.762.876.8980.070140.17713.765
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump51.9647.472.7631.4970.047450.18623
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump62.91312.872.916.3720.11770.29413.207
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 19.462.94312.150.20790.58793.592
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim)0.27678.5062.7551.3540.041510.12984.25
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim)0.16487.8653.0651.4590.059470.13113.175
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0.0969110.111.7951.974.0050.070352.514
ThermoSysPro.Examples.SimpleExamples.TestCheckValve4.21826.152.82719.230.23520.33533.667
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0.266911.43.8743.1630.039130.1594.187
ThermoSysPro.Examples.SimpleExamples.TestControlValve0.17411.462.8465.3820.13140.10383.019
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm0.207710.852.9574.8240.16150.099712.834
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim)9.00810.442.644.6260.047940.12823.031
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim)9.20410.512.5244.340.042830.14563.479
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim)38.9819.213.07612.090.17920.19643.693
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve2.82510.842.8594.710.17070.11833.05
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum (sim) 59.964.77546.130.75771.0787.25
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum1 (sim) 62.64.909480.87111.1777.675
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe3.27546.633.6237.090.58090.42264.935
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim)19.9117.843.04411.310.15370.15063.198
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe3.92550.754.93337.40.73071.0616.651
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim) 207.57.397180.21.4923.04215.39
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger1.6337.43.47528.990.35030.49284.118
ThermoSysPro.Examples.SimpleExamples.TestFan19.336.6223.080.30920.048340.12253.086
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions0.48626.5773.3220.098970.02980.076523.075
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes2.0767.3693.040.45920.05650.18913.648
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes10.57866.6673.0090.099530.030470.089373.466
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve5.52925.492.89318.120.2370.24434.021
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve0.828413.482.8655.9030.13870.69673.903
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0.245111.033.0123.9170.08730.10553.939
ThermoSysPro.Examples.SimpleExamples.TestJunctions0.767621.262.72614.690.18720.17073.545
ThermoSysPro.Examples.SimpleExamples.TestJunctions21.08929.362.96822.250.38450.21763.57
ThermoSysPro.Examples.SimpleExamples.TestJunctions34.90324.283.17216.960.22180.35823.591
ThermoSysPro.Examples.SimpleExamples.TestJunctions40.378314.012.7357.6680.088540.19783.347
ThermoSysPro.Examples.SimpleExamples.TestJunctions56.40730.153.02922.670.4770.25133.742
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker0.475213.222.5936.6740.030950.11643.826
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe6.96315.712.9049.1680.16680.27393.347
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier0.295310.652.6574.3340.032270.133.543
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim)1.92734.142.90427.260.063410.21493.744
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim)3.8635.913.08228.510.058450.64543.634
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim) 60.63.03452.870.090680.31994.308
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss0.269411.953.5964.1990.24450.099033.835
ThermoSysPro.Examples.SimpleExamples.TestRefP0.366510.553.2473.480.090040.12843.63
ThermoSysPro.Examples.SimpleExamples.TestSensors0.351616.193.3178.2480.37590.23274.094
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases0.398513.824.9634.5160.21690.12314.024
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser0.756422.363.53315.10.27510.28643.214
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss0.226810.582.8674.0510.83180.098492.753
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim)2.22210.52.7424.5690.055830.15223.019
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump10.162410.772.6914.5840.13840.12393.284
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump24.29910.92.6175.0290.120.11893.042
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0.0774410.511.8651.8233.5430.068443.24
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim) 30.423.26822.210.11640.22234.63
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum10.925815.972.9268.5970.062790.15864.249
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum20.646716.572.9769.4510.046010.1414.003
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases0.465215.225.465.2180.045820.15164.393
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger0.449625.93.50517.520.33820.32574.235
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff0.605920.163.39113.270.14680.13943.241
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer0.55816.463.2739.3760.14840.13433.55
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)0.594512.933.1146.3130.043590.14193.358
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine0.713415.014.2567.0780.10350.17243.454
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter0.555215.0638.640.088640.13733.221
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine (sim) 20.344.06312.650.14230.19873.303
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine1 (sim) 19.464.02311.830.12390.17513.336
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine20.552815.563.8078.3680.10060.16423.148
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine31.04524.913.84116.670.1730.4973.784
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve0.23049.6782.6563.750.33550.1242.836
ThermoSysPro.Examples.SimpleExamples.TestTank3.27113.73.1227.4220.14820.1412.903
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve0.849816.792.9810.20.25140.14073.305
ThermoSysPro.Examples.SimpleExamples.TestVolumes9.53427.413.01920.580.33830.28693.207
ThermoSysPro.Examples.SimpleExamples.TestVolumes19.46428.073.01921.180.43440.2323.227
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim) 25.892.94519.090.29710.29973.275
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 14.123.0627.4480.27970.19883.151