Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 71/83 succeeded

Total time taken: 940.2

OpenModelica Version: v1.9.4-dev.36+gedba84e

Test started: 2015-09-14 06:44:18

Tested Library: ThermoSysPro 3.1( revision 3.1+OSR-4-g51e7ea2 )

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("+d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 (sim) 427.821.86360.15.5218.7331.55
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim) 419.520.45353.95.5897.98231.6
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0.073286.9994.1760.094940.021130.076942.654
ThermoSysPro.Examples.SimpleExamples.TestBend0.214211.133.2354.7580.13550.16972.94
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump58.7311.913.5344.8050.067680.23293.29
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10.45979.9953.1723.4710.066850.17573.135
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump100.561416.463.2669.1780.16910.51663.357
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump110.606112.813.3366.0990.054740.17393.186
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)1.7968.3273.0021.3410.045530.16133.838
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump130.73677.7452.8681.3950.041280.13793.33
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump22.33613.673.0926.4810.11520.25973.743
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)7.63513.12.9886.2620.059940.32623.486
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump46.52413.082.9246.4010.062770.27663.445
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump52.2197.2812.6261.3110.045690.25323.068
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump63.10912.633.0765.8370.10760.34383.287
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 19.172.8412.260.19840.37873.519
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim)0.24877.0832.711.2670.039490.12432.965
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim)0.17757.0912.6711.3290.046560.18032.893
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0.107110.061.7911.9643.8810.081152.48
ThermoSysPro.Examples.SimpleExamples.TestCheckValve4.45526.312.94319.260.36630.31523.46
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0.29310.033.472.7210.07420.16943.621
ThermoSysPro.Examples.SimpleExamples.TestControlValve0.176410.792.8624.5660.21490.10773.06
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm0.215711.712.9845.5770.13130.11072.936
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim)9.20110.172.6724.4940.044830.13512.846
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim)9.16410.752.564.7730.058380.14653.268
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim)37.3518.542.8511.480.32270.18253.733
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve2.90910.262.9114.1110.086720.11443.061
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum (sim) 57.974.41645.080.76180.93376.805
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum1 (sim) 60.935.07546.630.77211.3957.083
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe2.945.453.6535.90.34790.60044.984
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim)20.2517.032.86510.640.20780.1833.151
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe3.974504.64436.980.77821.1056.518
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim) 200.97.321173.91.72.61415.47
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger1.62934.733.51926.450.4860.28744.009
ThermoSysPro.Examples.SimpleExamples.TestFan19.066.3743.0120.35820.049330.13582.843
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions0.35416.5453.0240.09550.030260.49652.926
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes1.9796.9543.1890.39020.092890.14673.159
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes10.55636.7843.0780.37550.029780.13063.194
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve6.10825.423.20917.690.23760.43683.865
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve0.824712.423.0076.0960.14560.17383.02
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0.19418.5572.7352.7280.085550.10622.928
ThermoSysPro.Examples.SimpleExamples.TestJunctions0.755521.612.94814.510.18660.39773.584
ThermoSysPro.Examples.SimpleExamples.TestJunctions21.06129.262.90821.910.4620.25113.756
ThermoSysPro.Examples.SimpleExamples.TestJunctions34.90923.43.10316.270.39380.23883.438
ThermoSysPro.Examples.SimpleExamples.TestJunctions40.41213.883.0667.0450.087060.2043.525
ThermoSysPro.Examples.SimpleExamples.TestJunctions55.96929.352.97421.980.48630.25883.679
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker0.421811.712.8565.6210.029380.16493.103
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe6.73115.82.7859.1480.16460.14473.579
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier0.30519.9682.6814.5380.026970.10672.639
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim)1.90133.733.05527.150.052630.18753.336
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim)3.90934.232.74227.750.060390.19963.508
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim) 59.63.00852.130.19980.29654.039
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss0.173110.472.9564.0690.55090.13362.838
ThermoSysPro.Examples.SimpleExamples.TestRefP0.2458.8353.0322.8760.085980.12722.858
ThermoSysPro.Examples.SimpleExamples.TestSensors0.301613.592.9397.1190.48220.11252.961
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases0.391312.34.7594.1990.030980.26473.068
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser0.759621.882.84714.740.25980.53663.519
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss0.164311.283.0574.2570.80780.21032.972
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim)1.9710.352.774.4940.03860.13553.103
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump10.171611.022.6244.9650.13860.12013.209
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump24.60510.312.6044.5320.039780.12043.036
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0.36310.11.7411.9253.6630.074632.748
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim) 30.993.25822.280.28290.21654.982
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum10.550416.792.8879.4440.086130.20524.2
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum20.566115.082.9098.2520.035120.12483.785
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases0.424414.515.3844.6350.034270.2364.245
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger0.504226.373.59616.790.37510.76084.909
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff0.686420.633.84312.990.17040.18913.522
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer0.46616.263.3558.8870.18750.13293.723
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)0.576913.32.8167.1180.034660.12373.246
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine0.654814.674.1986.8650.084580.15763.386
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter0.64414.512.937.8960.086530.22273.403
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine (sim) 20.284.17312.190.11440.22043.608
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine1 (sim) 19.894.07612.30.13890.18753.205
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine20.743815.284.0827.8390.092270.15893.13
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine31.07424.233.7216.290.17090.37253.708
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve0.239210.382.924.4840.13850.1172.743
ThermoSysPro.Examples.SimpleExamples.TestTank3.1413.732.7167.4860.14380.15753.258
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve0.847416.852.84210.750.19950.15012.933
ThermoSysPro.Examples.SimpleExamples.TestVolumes9.8628.563.10721.530.43410.22643.29
ThermoSysPro.Examples.SimpleExamples.TestVolumes19.525282.88521.230.45030.19763.259
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim) 25.712.96718.940.27670.29123.256
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 14.583.2697.70.20070.21143.219