Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 70/83 succeeded

Total time taken: 12m4s

OpenModelica Version: v1.9.3-dev.beta.60+gef238a6

Test started: 2015-09-02 06:53:59

Tested Library: ThermoSysPro 3.1( revision 3.1+OSR-4-g51e7ea2 )

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("+d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 (sim) 6m56s21s5m20s33s8s32s
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim) 7m8s20s5m20s47s7s31s
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0s7s4s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestBend0s11s3s4s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1m0s11s3s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10s10s3s2s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump100s15s3s8s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump110s13s2s7s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)2s8s3s1s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump130s7s2s1s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump22s13s3s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)7s12s2s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump46s13s2s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump51s8s2s1s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump62s13s2s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 19s2s12s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim)0s7s2s1s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim)0s7s2s1s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0s10s1s0s5s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCheckValve4s26s2s19s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0s10s3s2s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestControlValve0s11s2s5s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm0s11s2s5s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim)9s10s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim)9s10s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim)31s19s2s12s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve2s10s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum (sim) 1m2s4s47s1s1s7s
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum1 (sim) 1m3s4s48s1s1s7s
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe3s47s3s36s0s0s6s
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim) 18s3s11s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe3s54s4s40s1s0s6s
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim) 3m23s6s2m37s23s2s13s
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger1s36s3s27s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestFan18s6s2s0s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions0s6s2s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes2s6s2s0s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes10s6s2s0s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve5s25s2s18s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve0s12s2s6s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0s9s2s3s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestJunctions0s22s2s15s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestJunctions21s29s2s22s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestJunctions35s23s2s17s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestJunctions40s14s3s8s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestJunctions56s28s2s21s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker0s12s2s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe6s16s2s9s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier1s9s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim)1s33s2s27s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim)3s35s2s28s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim) 58s2s51s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss0s10s3s4s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestRefP0s9s3s3s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSensors0s14s2s7s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases0s13s4s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser0s21s2s14s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss0s10s2s4s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim)2s10s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump10s10s2s4s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump23s10s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0s10s1s0s5s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim) 29s2s20s0s0s5s
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum10s14s2s7s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum20s13s2s7s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases0s13s4s4s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger0s26s3s18s0s0s5s
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff1s21s3s14s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer0s16s3s9s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)0s14s2s7s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine0s16s4s8s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter0s14s2s8s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine (sim) 21s3s13s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine1 (sim) 20s4s12s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine20s15s4s8s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine31s24s3s16s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve0s10s2s4s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestTank3s13s2s7s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve0s17s2s11s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestVolumes9s28s2s21s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestVolumes19s26s3s19s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim) 26s2s19s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 14s2s7s0s0s3s

Offline version