Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 66/83 succeeded

Total time taken: 16m0s

OpenModelica Version: 1.9.2+dev (r24481)

Test started: 2015-02-09 07:09:42

Tested Library: ThermoSysPro 3.1( revision 21164 )

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("+d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 (sim) 6m14s22s4m32s20s8s50s
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim) 6m13s21s4m32s22s8s49s
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0s6s4s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestBend0s11s3s4s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4m30s10s3s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12s9s3s2s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump102s14s3s7s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump111s12s3s5s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)2s7s2s1s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump130s7s2s1s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump2 (sim)5s12s3s5s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)15s12s3s4s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4 (sim) 12s2s5s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump54s6s2s1s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump6 (sim)6s11s3s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump746s18s3s10s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim)1s6s2s1s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim)3s7s2s1s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0s9s1s0s5s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCheckValve32s25s3s17s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0s10s4s2s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestControlValve0s10s3s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm0s10s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim)19s9s2s3s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim) 9s2s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim)1m6s17s3s10s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve7s9s2s3s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum (sim) 56s4s40s1s1s8s
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum1 (sim) 58s5s42s1s1s9s
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe (sim) 42s3s31s0s0s6s
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim) 15s3s8s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe (sim) 48s4s32s0s0s8s
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim) 3m15s7s2m19s26s3s18s
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger11s32s3s23s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestFan23s6s3s0s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions0s5s2s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes2s6s2s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes10s5s3s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve (sim)30s24s3s16s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve (sim)4s12s3s5s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0s8s3s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestJunctions3s20s3s13s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestJunctions24s25s3s18s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestJunctions318s20s3s13s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestJunctions42s13s3s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestJunctions525s26s3s19s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker1s11s2s5s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe (sim)16s15s3s8s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier1s10s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim)35s32s3s25s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim) 32s3s25s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim) 53s3s45s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss0s9s3s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestRefP (sim)1s9s2s2s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSensors1s12s3s6s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases1s11s4s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser2s18s2s12s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss0s9s2s4s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump7s10s2s4s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump11s10s3s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump28s10s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0s9s1s0s5s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim) 24s3s17s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum12s12s2s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum22s12s2s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases1s12s5s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger4s19s3s12s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff5s17s2s10s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer3s12s2s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)3s11s2s5s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine1s13s4s5s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter3s13s3s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine (sim) 20s3s11s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine1 (sim) 19s4s10s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine22s15s4s7s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine3 (sim) 23s4s14s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve1s10s2s4s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestTank (sim)7s12s2s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve8s15s3s9s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestVolumes29s25s3s18s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestVolumes129s25s3s17s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim)2m35s23s3s16s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 14s3s6s0s0s3s

Offline version