Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 66/83 succeeded

Total time taken: 16m14s

OpenModelica Version: 1.9.2 Beta1 (r24372)

Test started: 2015-02-03 07:08:32

Tested Library: ThermoSysPro 3.1( revision 21164 )

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("+d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 (sim) 6m29s22s4m46s20s8s50s
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim) 6m22s23s4m39s21s7s50s
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0s6s4s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestBend0s11s3s4s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump5m18s10s3s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12s9s3s2s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump102s15s3s8s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump111s12s4s5s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)2s8s3s1s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump131s8s2s1s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump2 (sim)6s12s3s5s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)15s12s3s5s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4 (sim) 12s2s5s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump54s7s2s1s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump6 (sim)6s11s3s5s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump740s18s3s11s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim)1s7s2s1s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim)2s7s2s1s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0s10s1s0s5s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCheckValve33s24s3s17s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0s10s3s3s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestControlValve0s10s2s4s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm0s10s2s4s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim)20s9s2s3s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim) 9s2s4s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim)1m7s17s3s10s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve6s10s2s4s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum (sim) 56s4s40s1s1s9s
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum1 (sim) 59s5s42s1s0s9s
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe (sim) 43s3s32s0s0s5s
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim) 16s3s9s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe (sim) 48s4s33s1s1s8s
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim) 3m19s7s2m22s27s2s18s
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger11s32s3s23s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestFan24s6s3s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions0s5s2s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes2s6s3s0s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes10s5s2s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve (sim)30s23s3s16s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve (sim)4s12s3s5s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0s9s3s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestJunctions3s20s3s13s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestJunctions24s28s3s20s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestJunctions318s22s3s14s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestJunctions43s12s3s6s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestJunctions527s27s3s19s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker1s10s2s5s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe (sim)16s15s3s7s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier1s10s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim)30s32s3s25s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim) 33s3s26s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim) 54s3s46s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss0s9s2s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestRefP (sim)1s8s2s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestSensors1s14s3s6s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases1s12s4s3s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser2s19s3s13s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss0s9s2s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump8s9s2s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump11s10s2s4s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump29s11s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0s10s1s0s5s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim) 24s3s16s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum12s13s2s7s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum22s12s2s6s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases1s12s4s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger3s20s3s13s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff4s17s3s11s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer3s12s2s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)3s11s2s5s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine1s13s4s5s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter3s13s3s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine (sim) 20s4s11s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine1 (sim) 19s4s11s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine22s15s4s7s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine3 (sim) 23s4s14s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve1s10s2s4s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestTank (sim)7s12s2s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve9s15s2s9s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestVolumes29s26s3s19s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestVolumes133s25s3s18s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim)2m35s24s3s17s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 14s3s6s0s0s3s

Offline version