Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 62/83 succeeded

Total time taken: 16m25s

OpenModelica Version: 1.9.2+dev (r23920)

Test started: 2015-01-01 06:59:35

Tested Library: ThermoSysPro 3.1( revision 21164 )

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("+d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 (sim) 6m28s21s4m44s19s8s53s
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim) 6m17s20s4m37s19s7s52s
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0s7s4s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestBend1s11s3s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1m52s11s3s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12s10s3s2s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump105s16s3s8s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump11 (sim)1s13s3s5s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)3s8s3s1s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump131s7s2s1s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump26s12s3s5s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)17s13s2s5s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4 (sim)13s12s3s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump51s7s2s1s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump6 (sim) 11s3s5s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 18s2s10s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim)1s7s2s1s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim)2s7s2s1s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0s8s1s0s4s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCheckValve38s25s3s17s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0s10s3s2s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestControlValve1s10s3s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm1s9s3s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim) 9s2s3s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim) 10s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim) 19s3s11s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve6s10s3s4s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum (sim) 57s4s40s1s1s9s
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum1 (sim) 59s5s42s0s1s10s
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe (sim) 44s3s33s0s0s6s
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim) 16s3s9s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe (sim) 48s4s32s0s0s9s
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim) 2m57s7s2m18s7s2s20s
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger12s32s3s23s0s0s5s
ThermoSysPro.Examples.SimpleExamples.TestFan26s6s3s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions0s5s2s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes3s7s2s0s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes10s6s2s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve (sim)34s24s3s16s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve (sim)7s11s2s5s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0s8s3s2s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestJunctions4s20s3s13s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestJunctions26s26s3s19s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestJunctions3 (sim)48s22s3s15s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestJunctions46s13s3s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestJunctions528s27s3s19s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker1s11s2s5s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe (sim)19s13s2s7s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier1s9s2s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim)1m40s32s2s24s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim)1m44s34s2s26s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim) 55s3s47s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss1s10s2s4s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestRefP (sim)2s9s3s3s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSensors3s13s2s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases8s13s5s3s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser5s18s2s12s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss1s9s2s3s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump7s10s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump12s9s2s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump210s9s2s3s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0s7s1s0s3s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim) 25s3s17s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum1 (sim) 13s3s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum210s12s2s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases1s12s4s3s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger7s19s2s12s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff9s17s3s11s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer6s13s2s7s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)7s11s2s5s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine1s13s3s5s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter4s12s3s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine (sim) 20s4s12s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine1 (sim) 18s4s10s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine22s15s3s7s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine3 (sim) 24s4s15s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve2s9s3s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestTank (sim)9s12s3s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve (sim)10s15s3s9s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestVolumes32s26s3s19s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestVolumes133s25s3s18s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim) 24s3s17s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 14s3s6s0s0s4s