Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 52/83 succeeded

Total time taken: 20m32s

OpenModelica Version: 1.9.2+dev (r23393)

Test started: 2014-11-17 06:49:59

Tested Library: ThermoSysPro 3.1( revision 21164 )

BuildModel time limit: 660s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("+d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 (sim) 6m22s23s4m41s19s7s51s
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim) 6m25s22s4m46s19s8s49s
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0s7s4s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestBend1s10s4s3s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump (sim) 11s3s3s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1 (sim) 11s3s3s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump106s16s4s8s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump11 (sim)0s13s3s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)5s8s3s1s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump131s8s3s1s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump25s13s3s5s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)18s13s3s5s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4 (sim)16s12s3s5s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump52s8s3s1s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump6 (sim) 12s3s5s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 18s3s10s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim) 7s3s1s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim)2s7s2s1s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0s4s2s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCheckValve42s25s3s17s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0s11s4s3s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestControlValve1s10s3s4s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm2s11s3s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim) 10s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim) 10s3s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim) 18s3s10s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve5s10s3s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum (sim) 58s5s41s1s1s9s
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum1 (sim) 1m0s4s42s1s1s9s
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe (sim) 45s4s33s0s0s6s
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim) 16s3s9s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe (sim) 49s5s34s0s1s8s
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim) 2m54s7s2m16s7s2s19s
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger14s34s3s25s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestFan (sim) 6s3s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions1s5s2s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes3s6s3s0s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes1 (sim)1s5s2s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve (sim)7m18s24s3s16s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve (sim)6s12s3s5s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0s9s3s2s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestJunctions4s21s3s13s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestJunctions27s27s3s19s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestJunctions3 (sim) 22s3s14s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestJunctions4 (sim)6s13s3s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestJunctions5 (sim) 28s3s19s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker2s11s3s5s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe (sim)23s14s3s7s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier1s9s2s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim) 31s3s24s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim) 33s3s25s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim) 54s3s45s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss1s10s3s4s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestRefP (sim)3s8s3s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestSensors3s13s3s6s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases8s12s4s3s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser (sim)5s19s3s12s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss1s9s3s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim)9s10s3s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump12s9s3s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump2 (sim)11s9s3s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0s4s1s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim) 24s3s16s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum1 (sim) 13s3s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum212s13s3s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases1s12s5s3s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger7s20s3s13s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff10s17s3s10s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer7s13s3s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)9s11s3s5s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine1s14s4s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter5s13s3s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine (sim) 21s4s12s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine1 (sim) 20s4s11s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine23s17s4s8s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine3 (sim) 24s4s15s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve2s10s3s4s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestTank (sim)11s13s3s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve (sim) 15s3s9s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestVolumes (sim) 28s3s20s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestVolumes1 (sim)30s27s3s18s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim) 26s3s18s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 14s3s6s0s0s4s