Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 52/83 succeeded

Total time taken: 17m58s

OpenModelica Version: 1.9.1+dev (r22927) (RML version)

Test started: 2014-10-25 06:27:00

Tested Library: ThermoSysPro 3.1( revision 21164 )

BuildModel time limit: 480s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("+d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 (sim) 5m14s17s3m21s37s9s48s
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim) 4m27s16s3m22s8s5s32s
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0s5s3s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestBend2s8s2s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump (sim) 9s2s2s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1 (sim) 8s2s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump106s12s2s5s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump11 (sim) 10s2s3s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)12s6s2s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump131s6s2s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump26s10s2s3s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)20s10s2s3s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4 (sim)19s10s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump52s6s2s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump6 (sim) 10s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 15s2s7s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim) 7s2s0s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim)2s6s2s0s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0s4s1s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCheckValve45s19s2s12s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0s9s3s2s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestControlValve2s8s2s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm2s8s2s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim) 8s2s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim) 8s2s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim) 14s2s7s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve5s8s2s2s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum (sim) 44s3s29s1s1s8s
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum1 (sim) 46s4s31s1s1s8s
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe (sim) 33s3s23s0s0s6s
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim)28s12s2s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe (sim) 39s4s24s0s0s8s
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim) 2m16s6s1m40s7s2s18s
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger (sim)15s24s3s16s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestFan (sim) 5s2s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions1s5s2s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes4s5s2s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes1 (sim)1s4s2s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve (sim)37s18s2s11s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve (sim)4m45s9s2s3s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0s7s2s1s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestJunctions5s15s2s9s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestJunctions210s21s2s14s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestJunctions3 (sim) 17s2s10s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestJunctions4 (sim)7s11s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestJunctions5 (sim) 22s2s14s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker2s9s2s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe (sim)28s12s2s5s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier2s8s2s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim) 24s2s17s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim)1m43s25s2s18s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim) 41s2s33s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss2s8s2s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestRefP (sim)4s7s2s1s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestSensors3s11s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases12s10s3s2s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser (sim)7s15s2s9s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss1s8s2s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim)12s8s2s2s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump12s8s2s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump213s8s2s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0s4s1s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim) 19s2s12s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum1 (sim) 10s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum214s10s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases2s9s3s2s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger9s15s2s9s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff12s13s2s7s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer8s10s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)10s9s2s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine2s11s3s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter6s11s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine (sim) 16s4s8s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine1 (sim) 15s3s7s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine23s13s3s5s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine3 (sim) 19s3s11s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve2s8s2s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestTank (sim)11s11s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve (sim) 12s2s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestVolumes (sim) 21s3s14s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestVolumes1 (sim) 21s2s13s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim) 20s2s13s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 13s2s5s0s0s4s