Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 52/83 succeeded

Total time taken: 18m16s

OpenModelica Version: 1.9.1+dev (r22263) (RML version)

Test started: 2014-09-11 05:50:44

Tested Library: ThermoSysPro 3.1( revision 21164 )

BuildModel time limit: 480s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("+d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 (sim) 5m37s11s3m26s41s10s1m7s
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim) 4m36s11s3m25s9s6s42s
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0s5s2s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestBend2s8s2s2s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump (sim) 8s2s3s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1 (sim) 8s2s2s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump106s11s2s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump11 (sim) 9s2s4s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)12s6s2s1s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump131s6s2s1s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump26s9s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim)21s9s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4 (sim)19s9s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump52s6s2s1s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump6 (sim) 10s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 14s2s8s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim) 6s2s1s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim)2s6s2s1s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0s4s1s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCheckValve45s19s2s12s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0s8s3s2s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestControlValve2s8s2s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm2s8s2s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim) 8s2s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim) 8s2s2s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim) 14s2s7s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve5s8s2s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum (sim) 46s3s30s1s1s10s
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum1 (sim) 47s3s30s1s1s10s
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe (sim) 34s2s23s0s0s6s
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim)27s12s2s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe (sim) 41s3s24s0s1s11s
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim) 2m33s4s1m51s9s3s23s
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger (sim)16s26s2s17s0s0s5s
ThermoSysPro.Examples.SimpleExamples.TestFan (sim) 6s2s0s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions1s4s2s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes5s7s2s0s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes1 (sim)1s5s2s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve (sim)37s20s2s13s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve (sim)4m48s10s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0s8s2s2s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestJunctions5s19s2s12s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestJunctions29s22s2s15s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestJunctions3 (sim) 18s2s11s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestJunctions4 (sim)7s12s2s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestJunctions5 (sim) 24s3s16s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker2s11s2s4s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe (sim)28s12s2s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier2s10s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim) 31s3s23s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim)1m42s26s3s19s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim) 43s3s35s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss2s8s2s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestRefP (sim)4s7s2s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestSensors3s10s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases11s9s3s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser (sim)9s15s2s9s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss1s8s2s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim)13s9s2s3s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump12s9s2s3s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump212s10s2s3s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0s4s1s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim) 19s2s12s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum1 (sim) 10s2s5s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum215s10s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases2s10s4s2s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger10s15s2s9s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff13s13s2s8s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer28s10s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)30s9s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine2s11s3s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter16s11s2s5s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine (sim) 16s3s8s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine1 (sim) 16s3s8s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine24s12s3s5s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine3 (sim) 19s3s11s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve2s8s2s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestTank (sim)11s10s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve (sim) 13s2s6s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestVolumes (sim) 22s2s15s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestVolumes1 (sim) 22s3s14s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim) 20s2s13s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 12s2s5s0s0s4s