Recursive BuildModel Test

BuildModel Results: 83/83 succeeded

Simulation Results: 51/83 succeeded

Total time taken: 16m48s

OpenModelica Version: 1.9.1+dev (r21470) (RML version)

Test started: 2014-07-11 05:32:00

Tested Library: ThermoSysPro 3.1( revision 21164 )

BuildModel time limit: 480s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("+d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 (sim) 4m34s12s3m22s14s6s37s
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim) 4m34s12s3m22s15s6s37s
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0s5s3s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestBend2s8s3s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump (sim) 8s3s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1 (sim) 7s3s1s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump106s11s3s5s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump11 (sim) 9s3s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim)12s6s2s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump131s6s2s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump26s9s2s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim) 9s2s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4 (sim)18s9s2s3s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump52s6s2s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump6 (sim) 9s2s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 14s2s7s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim) 6s2s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim)2s6s2s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0s4s1s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCheckValve42s18s2s11s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0s8s3s1s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestControlValve2s8s2s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm1s8s2s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim) 8s2s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim) 8s2s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim) 14s3s7s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve5s8s2s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum (sim) 41s3s28s1s0s7s
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum1 (sim) 42s3s29s1s0s7s
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe (sim) 32s3s22s0s0s6s
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim)27s12s2s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe (sim) 37s3s22s0s1s9s
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim) 2m2s4s1m36s5s2s14s
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger (sim)15s23s2s15s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestFan (sim) 5s2s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions1s4s2s0s0s0s1s
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes4s6s2s0s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes1 (sim)1s4s2s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve (sim)35s17s2s10s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve (sim)4m39s9s2s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0s7s2s1s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestJunctions6s14s2s8s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestJunctions28s19s2s12s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestJunctions3 (sim) 16s2s9s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestJunctions4 (sim)7s10s2s4s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestJunctions5 (sim)7m44s19s2s13s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker2s8s2s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe (sim)27s12s2s5s0s0s4s
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier1s7s2s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim) 22s2s16s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim) 24s2s17s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim) 39s2s32s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss2s8s2s2s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestRefP (sim)4s7s2s1s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestSensors3s10s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases10s9s3s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser (sim)9s14s2s8s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss1s7s2s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim)10s7s2s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump12s8s2s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump211s8s2s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0s4s1s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim) 18s3s11s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum1 (sim) 10s2s4s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum213s10s2s4s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases2s9s3s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger8s14s2s8s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff11s12s2s6s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer31s10s2s4s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)28s9s2s3s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine2s11s3s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter15s10s2s4s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine (sim) 15s3s7s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine1 (sim) 15s3s7s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine23s12s4s5s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine3 (sim) 18s3s10s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve2s7s2s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestTank (sim)10s10s2s4s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve (sim) 12s2s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestVolumes (sim) 20s2s13s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestVolumes1 (sim) 19s2s12s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim) 19s2s12s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 11s2s4s0s0s3s

Offline version