Recursive BuildModel Test

BuildModel Results: 62/62 succeeded

Simulation Results: 46/62 succeeded

Total time taken: 16m56s

OpenModelica Version: 1.9.1+dev (r20821) (RML version)

Test started: 2014-05-26 05:25:06

Tested Library: ThermoSysPro 3.0 revision 20164

BuildModel time limit: 600s

Simulation time limit: 480s

Default tolerance: 1e-06

Flags:
setCommandLineOptions("+d=nogen,initialization,backenddaeinfo,discreteinfo,stateselection");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

Green cells means success. Red is bad and in general signifies a failure.

ModelSimulateTotal buildModelFrontendBackendSimCodeTemplatesCompile
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 (sim) 4m45s14s3m31s14s6s38s
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim) 4m47s14s3m32s16s6s38s
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity0s5s3s0s0s0s1s
ThermoSysPro.Examples.SimpleExamples.TestBend2s9s3s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution0s4s2s0s0s0s1s
ThermoSysPro.Examples.SimpleExamples.TestCheckValve39s20s3s13s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim)0s9s4s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestControlValve2s9s3s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm2s9s3s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim) 9s3s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim) 8s3s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim) 15s3s8s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve4s9s3s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum (sim) 50s4s31s7s0s7s
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe (sim) 36s3s24s0s0s6s
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim)22s13s3s7s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe (sim)1m17s41s4s25s0s1s9s
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger (sim)15s25s3s17s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestFan (sim) 4s1s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions1s3s1s0s0s0s1s
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes1s3s1s0s0s0s1s
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes10s4s1s0s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve (sim)6m58s19s3s11s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve6s10s3s4s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss0s8s3s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestJunctions5s16s3s9s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestJunctions28s22s3s14s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestJunctions3 (sim)3m24s18s3s10s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestJunctions4 (sim)7s11s3s5s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestJunctions5 (sim)25s22s3s14s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe18s13s3s6s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier2s8s3s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss1s9s3s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestRefP4s8s3s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestSensors3s11s3s4s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases10s10s4s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser (sim)8s16s3s10s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss2s9s3s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim) 9s3s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump12s9s4s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump2 (sim)9s8s3s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim)0s4s2s0s0s0s1s
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim) 19s3s12s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum1 (sim) 11s3s4s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum215s10s3s4s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases2s10s4s2s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger8s16s3s10s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff11s14s3s8s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer24s11s3s4s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim)25s10s3s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine2s12s4s4s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter15s11s3s4s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine (sim) 17s5s8s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine1 (sim) 17s5s8s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine23s13s4s5s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve2s9s3s3s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestTank15s11s3s5s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve (sim) 13s3s7s0s0s2s
ThermoSysPro.Examples.SimpleExamples.TestVolumes (sim)6m30s22s3s15s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestVolumes1 (sim)26s22s3s14s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim) 21s3s14s0s0s3s
ThermoSysPro.Examples.SimpleExamples.TestWaterHammer (sim) 12s3s5s0s0s2s

Offline version