tests / testsuite-gcc / simulation_libraries_3rdParty_ThermoSysPro.ThermoSysPro.Examples.SimpleExamples.TestAirHumidity.mos (from (result.xml))
Stacktrace
Output mismatch (see stdout for details)
Standard Output
+ ThermoSysPro.Examples.SimpleExamples.TestAirHumidity.mos [simulation checking] ... equation mismatch [time: 0] ==== Log /tmp/omc-rtest-unknown/simulation/libraries/3rdParty/ThermoSysPro/ThermoSysPro.Examples.SimpleExamples.TestAirHumidity.mos_temp9467/log-ThermoSysPro.Examples.SimpleExamples.TestAirHumidity.mos false "Error: Failed to load package Modelica (3.2.1) using MODELICAPATH /var/lib/jenkins/workspace/OpenModelica_maintenance_v1.13/build/lib/omlibrary. " false "Error: Failed to load package ThermoSysPro (default) using MODELICAPATH /var/lib/jenkins/workspace/OpenModelica_maintenance_v1.13/build/lib/omlibrary. " record SimulationResult resultFile = "", simulationOptions = "startTime = 0.0, stopTime = 1000.0, numberOfIntervals = 500, tolerance = 1e-06, method = 'dassl', fileNamePrefix = 'ThermoSysPro.Examples.SimpleExamples.TestAirHumidity', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''", messages = "Simulation Failed. Model: ThermoSysPro.Examples.SimpleExamples.TestAirHumidity does not exist! Please load it first before simulation." end SimulationResult; "" {"Error opening file: /var/lib/jenkins/workspace/OpenModelica_maintenance_v1.13/testsuite/simulation/libraries/3rdParty/ThermoSysPro/ThermoSysPro.Examples.SimpleExamples.TestAirHumidity.mos_temp9467/ThermoSysPro.Examples.SimpleExamples.TestAirHumidity_res.mat"} Equation mismatch: diff says: --- /tmp/omc-rtest-unknown/simulation/libraries/3rdParty/ThermoSysPro/ThermoSysPro.Examples.SimpleExamples.TestAirHumidity.mos_temp9467/equations-expected2019-01-31 14:13:59.381755374 +0000 +++ /tmp/omc-rtest-unknown/simulation/libraries/3rdParty/ThermoSysPro/ThermoSysPro.Examples.SimpleExamples.TestAirHumidity.mos_temp9467/equations-got2019-01-31 14:13:59.529754702 +0000 @@ -1,21 +1,13 @@ -true -"" -true -"" +false +"Error: Failed to load package Modelica (3.2.1) using MODELICAPATH /var/lib/jenkins/workspace/OpenModelica_maintenance_v1.13/build/lib/omlibrary. +" +false +"Error: Failed to load package ThermoSysPro (default) using MODELICAPATH /var/lib/jenkins/workspace/OpenModelica_maintenance_v1.13/build/lib/omlibrary. +" record SimulationResult -resultFile = "ThermoSysPro.Examples.SimpleExamples.TestAirHumidity_res.mat", +resultFile = "", simulationOptions = "startTime = 0.0, stopTime = 1000.0, numberOfIntervals = 500, tolerance = 1e-06, method = 'dassl', fileNamePrefix = 'ThermoSysPro.Examples.SimpleExamples.TestAirHumidity', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''", -messages = "LOG_SUCCESS | info | The initialization finished successfully without homotopy method. -LOG_SUCCESS | info | The simulation finished successfully. -" +messages = "Simulation Failed. Model: ThermoSysPro.Examples.SimpleExamples.TestAirHumidity does not exist! Please load it first before simulation." end SimulationResult; -"[ThermoSysPro 3.1/FlueGases/Connectors.mo:3:3-53:22:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesOutlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). -[ThermoSysPro 3.1/FlueGases/Connectors.mo:55:3-105:21:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesInlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). -[ThermoSysPro 3.1/FlueGases/Connectors.mo:3:3-53:22:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesOutlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). -[ThermoSysPro 3.1/Properties/WaterSteam/Common.mo:703:3-754:22:writable] Warning: pro.x was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. -[ThermoSysPro 3.1/Properties/WaterSteam/Common.mo:1185:3-1241:26:writable] Warning: pro.x was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. -[ThermoSysPro 3.1/FlueGases/Connectors.mo:55:3-105:21:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesInlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). -[ThermoSysPro 3.1/FlueGases/Connectors.mo:3:3-53:22:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesOutlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). -[ThermoSysPro 3.1/FlueGases/Connectors.mo:55:3-105:21:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesInlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). -" -{"Files Equal!"} +"" +{"Error opening file: /var/lib/jenkins/workspace/OpenModelica_maintenance_v1.13/testsuite/simulation/libraries/3rdParty/ThermoSysPro/ThermoSysPro.Examples.SimpleExamples.TestAirHumidity.mos_temp9467/ThermoSysPro.Examples.SimpleExamples.TestAirHumidity_res.mat"} Equation mismatch: omc-diff says: Failed 't' 'f' Line 1: Text differs: expected: true got: false == 1 out of 1 tests failed [simulation/libraries/3rdParty/ThermoSysPro/ThermoSysPro.Examples.SimpleExamples.TestAirHumidity.mos_temp9467, time: 0]