Failed
simulation_modelica_initialization.OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos (from (result.xml))
Stacktrace
Output mismatch (see stdout for details)
Standard Output
+ OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization ... equation mismatch [time: 17] ==== Log C:\Windows\TEMP/omc-rtest-OpenModelica/simulation/modelica/initialization/OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899/log-OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos true "" true "" true "" Warning: Maximum path length limitation reached while opening C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos Consider changing the working directory, using shorter names or to enable longer paths in Windows. See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. Warning: Maximum path length limitation reached while opening C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos Consider changing the working directory, using shorter names or to enable longer paths in Windows. See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. Warning: Maximum path length limitation reached while opening C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos Consider changing the working directory, using shorter names or to enable longer paths in Windows. See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. Warning: Maximum path length limitation reached while opening C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos Consider changing the working directory, using shorter names or to enable longer paths in Windows. See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. Warning: Maximum path length limitation reached while opening C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos Consider changing the working directory, using shorter names or to enable longer paths in Windows. See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. Warning: Maximum path length limitation reached while opening C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos Consider changing the working directory, using shorter names or to enable longer paths in Windows. See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. Warning: Maximum path length limitation reached while opening C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos Consider changing the working directory, using shorter names or to enable longer paths in Windows. See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. Warning: Maximum path length limitation reached while opening C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos Consider changing the working directory, using shorter names or to enable longer paths in Windows. See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. Warning: Maximum path length limitation reached while opening C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos Consider changing the working directory, using shorter names or to enable longer paths in Windows. See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. Warning: Maximum path length limitation reached while opening C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos Consider changing the working directory, using shorter names or to enable longer paths in Windows. See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. Warning: Maximum path length limitation reached while opening C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos Consider changing the working directory, using shorter names or to enable longer paths in Windows. See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. Warning: Maximum path length limitation reached while opening C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos Consider changing the working directory, using shorter names or to enable longer paths in Windows. See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. Warning: Maximum path length limitation reached while opening C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos Consider changing the working directory, using shorter names or to enable longer paths in Windows. See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. Warning: Maximum path length limitation reached while opening C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos Consider changing the working directory, using shorter names or to enable longer paths in Windows. See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. Warning: Maximum path length limitation reached while opening C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos Consider changing the working directory, using shorter names or to enable longer paths in Windows. See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. Warning: Maximum path length limitation reached while opening C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos Consider changing the working directory, using shorter names or to enable longer paths in Windows. See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. Warning: Maximum path length limitation reached while opening C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos Consider changing the working directory, using shorter names or to enable longer paths in Windows. See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. Warning: Maximum path length limitation reached while opening C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos Consider changing the working directory, using shorter names or to enable longer paths in Windows. See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. Warning: Maximum path length limitation reached while opening C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos Consider changing the working directory, using shorter names or to enable longer paths in Windows. See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. Warning: Maximum path length limitation reached while opening C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos Consider changing the working directory, using shorter names or to enable longer paths in Windows. See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. Warning: Maximum path length limitation reached while opening C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos Consider changing the working directory, using shorter names or to enable longer paths in Windows. See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. Warning: Maximum path length limitation reached while opening C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos Consider changing the working directory, using shorter names or to enable longer paths in Windows. See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. Warning: Maximum path length limitation reached while opening C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos Consider changing the working directory, using shorter names or to enable longer paths in Windows. See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. Warning: Maximum path length limitation reached while opening C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos Consider changing the working directory, using shorter names or to enable longer paths in Windows. See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. Warning: Maximum path length limitation reached while opening C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos Consider changing the working directory, using shorter names or to enable longer paths in Windows. See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. Warning: Maximum path length limitation reached while opening C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos Consider changing the working directory, using shorter names or to enable longer paths in Windows. See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. Warning: Maximum path length limitation reached while opening C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos Consider changing the working directory, using shorter names or to enable longer paths in Windows. See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. Warning: Maximum path length limitation reached while opening C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos Consider changing the working directory, using shorter names or to enable longer paths in Windows. See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. Warning: Maximum path length limitation reached while opening C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos Consider changing the working directory, using shorter names or to enable longer paths in Windows. See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. Warning: Maximum path length limitation reached while opening C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos Consider changing the working directory, using shorter names or to enable longer paths in Windows. See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. Warning: Maximum path length limitation reached while opening C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos Consider changing the working directory, using shorter names or to enable longer paths in Windows. See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. Warning: Maximum path length limitation reached while opening C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos Consider changing the working directory, using shorter names or to enable longer paths in Windows. See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. {"",""} "Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Warning: Assuming fixed start value for the following 1 variables: m_flow_initial:DISCRETE(unit = \"kg/s\" fixed = true ) type: Real Warning: The initial conditions are over specified. The following 4 initial equations are redundant, so they are removed from the initialization system: $DER.pipe.mediums[1].p = 0.0 $DER.pipe.mediums[2].p = 0.0 $DER.pipe.mediums[3].p = 0.0 $DER.pipe.mediums[4].p = 0.0. Warning: Assuming fixed start value for the following 1 variables: m_flow_initial:DISCRETE(unit = \"kg/s\" fixed = true ) type: Real Warning: The initial conditions are over specified. The following 4 initial equations are redundant, so they are removed from the initialization_lambda0 system: $DER.pipe.mediums[1].p = 0.0 $DER.pipe.mediums[2].p = 0.0 $DER.pipe.mediums[3].p = 0.0 $DER.pipe.mediums[4].p = 0.0. Error: Error building simulator. Build log: make: Entering directory '/c/dev/jenkins/ws/Windows/OM_Win/TESTSU~1/SIMULA~1/modelica/INITIA~1/OVF4C6~1.MOS' clang -municode -O0 -DOM_HAVE_PTHREADS -Wno-parentheses-equality -falign-functions -mstackrealign -msse2 -mfpmath=sse \"-IC:/dev/jenkins/ws/Windows/OM_Win/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc/c\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=OverdeterminedInitialization_Fluid_DynamicPipeLumpedPressureInitialization -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.c clang -municode -O0 -DOM_HAVE_PTHREADS -Wno-parentheses-equality -falign-functions -mstackrealign -msse2 -mfpmath=sse \"-IC:/dev/jenkins/ws/Windows/OM_Win/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc/c\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=OverdeterminedInitialization_Fluid_DynamicPipeLumpedPressureInitialization -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_functions.o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_functions.c clang -municode -O0 -DOM_HAVE_PTHREADS -Wno-parentheses-equality -falign-functions -mstackrealign -msse2 -mfpmath=sse \"-IC:/dev/jenkins/ws/Windows/OM_Win/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc/c\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=OverdeterminedInitialization_Fluid_DynamicPipeLumpedPressureInitialization -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_records.o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_records.c clang -municode -O0 -DOM_HAVE_PTHREADS -Wno-parentheses-equality -falign-functions -mstackrealign -msse2 -mfpmath=sse \"-IC:/dev/jenkins/ws/Windows/OM_Win/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc/c\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=OverdeterminedInitialization_Fluid_DynamicPipeLumpedPressureInitialization -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_01exo.o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_01exo.c clang -municode -O0 -DOM_HAVE_PTHREADS -Wno-parentheses-equality -falign-functions -mstackrealign -msse2 -mfpmath=sse \"-IC:/dev/jenkins/ws/Windows/OM_Win/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc/c\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=OverdeterminedInitialization_Fluid_DynamicPipeLumpedPressureInitialization -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_02nls.o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_02nls.c clang -municode -O0 -DOM_HAVE_PTHREADS -Wno-parentheses-equality -falign-functions -mstackrealign -msse2 -mfpmath=sse \"-IC:/dev/jenkins/ws/Windows/OM_Win/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc/c\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=OverdeterminedInitialization_Fluid_DynamicPipeLumpedPressureInitialization -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_03lsy.o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_03lsy.c clang -municode -O0 -DOM_HAVE_PTHREADS -Wno-parentheses-equality -falign-functions -mstackrealign -msse2 -mfpmath=sse \"-IC:/dev/jenkins/ws/Windows/OM_Win/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc/c\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=OverdeterminedInitialization_Fluid_DynamicPipeLumpedPressureInitialization -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_04set.o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_04set.c clang -municode -O0 -DOM_HAVE_PTHREADS -Wno-parentheses-equality -falign-functions -mstackrealign -msse2 -mfpmath=sse \"-IC:/dev/jenkins/ws/Windows/OM_Win/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc/c\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=OverdeterminedInitialization_Fluid_DynamicPipeLumpedPressureInitialization -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_05evt.o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_05evt.c clang -municode -O0 -DOM_HAVE_PTHREADS -Wno-parentheses-equality -falign-functions -mstackrealign -msse2 -mfpmath=sse \"-IC:/dev/jenkins/ws/Windows/OM_Win/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc/c\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=OverdeterminedInitialization_Fluid_DynamicPipeLumpedPressureInitialization -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_06inz.o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_06inz.c clang -municode -O0 -DOM_HAVE_PTHREADS -Wno-parentheses-equality -falign-functions -mstackrealign -msse2 -mfpmath=sse \"-IC:/dev/jenkins/ws/Windows/OM_Win/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc/c\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=OverdeterminedInitialization_Fluid_DynamicPipeLumpedPressureInitialization -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_07dly.o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_07dly.c clang -municode -O0 -DOM_HAVE_PTHREADS -Wno-parentheses-equality -falign-functions -mstackrealign -msse2 -mfpmath=sse \"-IC:/dev/jenkins/ws/Windows/OM_Win/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc/c\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=OverdeterminedInitialization_Fluid_DynamicPipeLumpedPressureInitialization -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_08bnd.o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_08bnd.c clang -municode -O0 -DOM_HAVE_PTHREADS -Wno-parentheses-equality -falign-functions -mstackrealign -msse2 -mfpmath=sse \"-IC:/dev/jenkins/ws/Windows/OM_Win/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc/c\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=OverdeterminedInitialization_Fluid_DynamicPipeLumpedPressureInitialization -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_09alg.o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_09alg.c 0 [main] make (5109124) child_copy: cygheap read copy failed, 0x0..0x80000A498, done 0, windows pid 5109124, Win32 error 299 0 [main] make 2545 dofork: child -1 - forked process 5109124 died unexpectedly, retry 0, exit code 0xC0000142, errno 11 make: *** [<builtin>: OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_09alg.o] Error 127 make: Leaving directory '/c/dev/jenkins/ws/Windows/OM_Win/TESTSU~1/SIMULA~1/modelica/INITIA~1/OVF4C6~1.MOS' RESULT: 2 " '' Equation mismatch: diff says: --- "C:\\Windows\\TEMP/omc-rtest-OpenModelica/simulation/modelica/initialization/OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899/equations-expected"2024-06-13 15:20:46.804648500 +0200 +++ "C:\\Windows\\TEMP/omc-rtest-OpenModelica/simulation/modelica/initialization/OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899/equations-got"2024-06-13 15:21:03.071444200 +0200 @@ -2,11 +2,139 @@ "" true "" true "" -{"OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization","OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_init.xml"} +Warning: Maximum path length limitation reached while opening +C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos +Consider changing the working directory, using shorter names or to enable longer paths in Windows. +See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. +Warning: Maximum path length limitation reached while opening +C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos +Consider changing the working directory, using shorter names or to enable longer paths in Windows. +See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. +Warning: Maximum path length limitation reached while opening +C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos +Consider changing the working directory, using shorter names or to enable longer paths in Windows. +See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. +Warning: Maximum path length limitation reached while opening +C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos +Consider changing the working directory, using shorter names or to enable longer paths in Windows. +See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. +Warning: Maximum path length limitation reached while opening +C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos +Consider changing the working directory, using shorter names or to enable longer paths in Windows. +See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. +Warning: Maximum path length limitation reached while opening +C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos +Consider changing the working directory, using shorter names or to enable longer paths in Windows. +See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. +Warning: Maximum path length limitation reached while opening +C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos +Consider changing the working directory, using shorter names or to enable longer paths in Windows. +See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. +Warning: Maximum path length limitation reached while opening +C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos +Consider changing the working directory, using shorter names or to enable longer paths in Windows. +See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. +Warning: Maximum path length limitation reached while opening +C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos +Consider changing the working directory, using shorter names or to enable longer paths in Windows. +See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. +Warning: Maximum path length limitation reached while opening +C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos +Consider changing the working directory, using shorter names or to enable longer paths in Windows. +See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. +Warning: Maximum path length limitation reached while opening +C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos +Consider changing the working directory, using shorter names or to enable longer paths in Windows. +See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. +Warning: Maximum path length limitation reached while opening +C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos +Consider changing the working directory, using shorter names or to enable longer paths in Windows. +See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. +Warning: Maximum path length limitation reached while opening +C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos +Consider changing the working directory, using shorter names or to enable longer paths in Windows. +See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. +Warning: Maximum path length limitation reached while opening +C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos +Consider changing the working directory, using shorter names or to enable longer paths in Windows. +See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. +Warning: Maximum path length limitation reached while opening +C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos +Consider changing the working directory, using shorter names or to enable longer paths in Windows. +See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. +Warning: Maximum path length limitation reached while opening +C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos +Consider changing the working directory, using shorter names or to enable longer paths in Windows. +See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. +Warning: Maximum path length limitation reached while opening +C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos +Consider changing the working directory, using shorter names or to enable longer paths in Windows. +See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. +Warning: Maximum path length limitation reached while opening +C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos +Consider changing the working directory, using shorter names or to enable longer paths in Windows. +See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. +Warning: Maximum path length limitation reached while opening +C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos +Consider changing the working directory, using shorter names or to enable longer paths in Windows. +See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. +Warning: Maximum path length limitation reached while opening +C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos +Consider changing the working directory, using shorter names or to enable longer paths in Windows. +See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. +Warning: Maximum path length limitation reached while opening +C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos +Consider changing the working directory, using shorter names or to enable longer paths in Windows. +See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. +Warning: Maximum path length limitation reached while opening +C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos +Consider changing the working directory, using shorter names or to enable longer paths in Windows. +See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. +Warning: Maximum path length limitation reached while opening +C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos +Consider changing the working directory, using shorter names or to enable longer paths in Windows. +See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. +Warning: Maximum path length limitation reached while opening +C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos +Consider changing the working directory, using shorter names or to enable longer paths in Windows. +See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. +Warning: Maximum path length limitation reached while opening +C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos +Consider changing the working directory, using shorter names or to enable longer paths in Windows. +See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. +Warning: Maximum path length limitation reached while opening +C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos +Consider changing the working directory, using shorter names or to enable longer paths in Windows. +See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. +Warning: Maximum path length limitation reached while opening +C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos +Consider changing the working directory, using shorter names or to enable longer paths in Windows. +See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. +Warning: Maximum path length limitation reached while opening +C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos +Consider changing the working directory, using shorter names or to enable longer paths in Windows. +See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. +Warning: Maximum path length limitation reached while opening +C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos +Consider changing the working directory, using shorter names or to enable longer paths in Windows. +See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. +Warning: Maximum path length limitation reached while opening +C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos +Consider changing the working directory, using shorter names or to enable longer paths in Windows. +See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. +Warning: Maximum path length limitation reached while opening +C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos +Consider changing the working directory, using shorter names or to enable longer paths in Windows. +See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. +Warning: Maximum path length limitation reached while opening +C:\dev\jenkins\ws\Windows\OM_Win\testsuite\simulation\modelica\initialization\OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899\rtest5101692.rfJ1h.tmpOverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos +Consider changing the working directory, using shorter names or to enable longer paths in Windows. +See https://docs.microsoft.com/en-us/windows/win32/fileio/maximum-file-path-limitation for more information. +{"",""} "Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Warning: Assuming fixed start value for the following 1 variables: m_flow_initial:DISCRETE(unit = \"kg/s\" fixed = true ) type: Real Warning: The initial conditions are over specified. The following 4 initial equations are redundant, so they are removed from the initialization system: $DER.pipe.mediums[1].p = 0.0 @@ -18,6 +146,24 @@ Warning: The initial conditions are over specified. The following 4 initial equations are redundant, so they are removed from the initialization_lambda0 system: $DER.pipe.mediums[1].p = 0.0 $DER.pipe.mediums[2].p = 0.0 $DER.pipe.mediums[3].p = 0.0 $DER.pipe.mediums[4].p = 0.0. +Error: Error building simulator. Build log: make: Entering directory '/c/dev/jenkins/ws/Windows/OM_Win/TESTSU~1/SIMULA~1/modelica/INITIA~1/OVF4C6~1.MOS' +clang -municode -O0 -DOM_HAVE_PTHREADS -Wno-parentheses-equality -falign-functions -mstackrealign -msse2 -mfpmath=sse \"-IC:/dev/jenkins/ws/Windows/OM_Win/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc/c\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=OverdeterminedInitialization_Fluid_DynamicPipeLumpedPressureInitialization -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.c +clang -municode -O0 -DOM_HAVE_PTHREADS -Wno-parentheses-equality -falign-functions -mstackrealign -msse2 -mfpmath=sse \"-IC:/dev/jenkins/ws/Windows/OM_Win/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc/c\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=OverdeterminedInitialization_Fluid_DynamicPipeLumpedPressureInitialization -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_functions.o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_functions.c +clang -municode -O0 -DOM_HAVE_PTHREADS -Wno-parentheses-equality -falign-functions -mstackrealign -msse2 -mfpmath=sse \"-IC:/dev/jenkins/ws/Windows/OM_Win/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc/c\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=OverdeterminedInitialization_Fluid_DynamicPipeLumpedPressureInitialization -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_records.o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_records.c +clang -municode -O0 -DOM_HAVE_PTHREADS -Wno-parentheses-equality -falign-functions -mstackrealign -msse2 -mfpmath=sse \"-IC:/dev/jenkins/ws/Windows/OM_Win/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc/c\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=OverdeterminedInitialization_Fluid_DynamicPipeLumpedPressureInitialization -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_01exo.o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_01exo.c +clang -municode -O0 -DOM_HAVE_PTHREADS -Wno-parentheses-equality -falign-functions -mstackrealign -msse2 -mfpmath=sse \"-IC:/dev/jenkins/ws/Windows/OM_Win/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc/c\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=OverdeterminedInitialization_Fluid_DynamicPipeLumpedPressureInitialization -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_02nls.o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_02nls.c +clang -municode -O0 -DOM_HAVE_PTHREADS -Wno-parentheses-equality -falign-functions -mstackrealign -msse2 -mfpmath=sse \"-IC:/dev/jenkins/ws/Windows/OM_Win/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc/c\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=OverdeterminedInitialization_Fluid_DynamicPipeLumpedPressureInitialization -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_03lsy.o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_03lsy.c +clang -municode -O0 -DOM_HAVE_PTHREADS -Wno-parentheses-equality -falign-functions -mstackrealign -msse2 -mfpmath=sse \"-IC:/dev/jenkins/ws/Windows/OM_Win/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc/c\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=OverdeterminedInitialization_Fluid_DynamicPipeLumpedPressureInitialization -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_04set.o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_04set.c +clang -municode -O0 -DOM_HAVE_PTHREADS -Wno-parentheses-equality -falign-functions -mstackrealign -msse2 -mfpmath=sse \"-IC:/dev/jenkins/ws/Windows/OM_Win/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc/c\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=OverdeterminedInitialization_Fluid_DynamicPipeLumpedPressureInitialization -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_05evt.o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_05evt.c +clang -municode -O0 -DOM_HAVE_PTHREADS -Wno-parentheses-equality -falign-functions -mstackrealign -msse2 -mfpmath=sse \"-IC:/dev/jenkins/ws/Windows/OM_Win/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc/c\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=OverdeterminedInitialization_Fluid_DynamicPipeLumpedPressureInitialization -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_06inz.o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_06inz.c +clang -municode -O0 -DOM_HAVE_PTHREADS -Wno-parentheses-equality -falign-functions -mstackrealign -msse2 -mfpmath=sse \"-IC:/dev/jenkins/ws/Windows/OM_Win/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc/c\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=OverdeterminedInitialization_Fluid_DynamicPipeLumpedPressureInitialization -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_07dly.o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_07dly.c +clang -municode -O0 -DOM_HAVE_PTHREADS -Wno-parentheses-equality -falign-functions -mstackrealign -msse2 -mfpmath=sse \"-IC:/dev/jenkins/ws/Windows/OM_Win/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc/c\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=OverdeterminedInitialization_Fluid_DynamicPipeLumpedPressureInitialization -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_08bnd.o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_08bnd.c +clang -municode -O0 -DOM_HAVE_PTHREADS -Wno-parentheses-equality -falign-functions -mstackrealign -msse2 -mfpmath=sse \"-IC:/dev/jenkins/ws/Windows/OM_Win/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc/c\" -I\"C:/dev/jenkins/ws/Windows/OM_Win/build/include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=OverdeterminedInitialization_Fluid_DynamicPipeLumpedPressureInitialization -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=3 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_09alg.o OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_09alg.c +0 [main] make (5109124) child_copy: cygheap read copy failed, 0x0..0x80000A498, done 0, windows pid 5109124, Win32 error 299 +0 [main] make 2545 dofork: child -1 - forked process 5109124 died unexpectedly, retry 0, exit code 0xC0000142, errno 11 +make: *** [<builtin>: OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_09alg.o] Error 127 +make: Leaving directory '/c/dev/jenkins/ws/Windows/OM_Win/TESTSU~1/SIMULA~1/modelica/INITIA~1/OVF4C6~1.MOS' +RESULT: 2 " '' Equation mismatch: omc-diff says: Failed '{' 'W' Line 7: Text differs: expected: {"OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization","OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization_init.xml"} got: Warning: Maximum path length limitation reached while opening == 1 out of 1 tests failed [simulation/modelica/initialization/OverdeterminedInitialization.Fluid.DynamicPipeLumpedPressureInitialization.mos_temp5899, time: 27]