Skip to content

Regression

simulation_libraries_3rdParty_ThermoSysPro.ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes.mos (from (result.xml))

Failing for the past 1 build (Since #3812 )
Took 19 sec.

Stacktrace

Output mismatch (see stdout for details)

Standard Output

 + ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes.mos [simulation checking]... equation mismatch [time: 9]

==== Log C:\Windows\TEMP/omc-rtest-OpenModelica/simulation/libraries/3rdParty/ThermoSysPro/ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes.mos_temp464/log-ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes.mos
true
""

"Warning: Out of memory! Faking a stack overflow.
Error: Stack overflow occurred while evaluating loadModel(ThermoSysPro):
[bt] [Symbols are not generated when running the test suite]
"
record SimulationResult
    resultFile = "",
    simulationOptions = "startTime = 0.0, stopTime = 200.0, numberOfIntervals = 500, tolerance = 1e-6, method = 'dassl', fileNamePrefix = 'ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "Simulation Failed. Model: ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes does not exist! Please load it first before simulation."
end SimulationResult;
""
"Error in compareSimulationResults"
'' 
Equation mismatch: diff says: 
--- "C:\\Windows\\TEMP/omc-rtest-OpenModelica/simulation/libraries/3rdParty/ThermoSysPro/ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes.mos_temp464/equations-expected"2024-06-13 15:18:53.895440600 +0200
+++ "C:\\Windows\\TEMP/omc-rtest-OpenModelica/simulation/libraries/3rdParty/ThermoSysPro/ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes.mos_temp464/equations-got"2024-06-13 15:19:02.575302600 +0200
@@ -1,45 +1,14 @@
 true
 ""
-true
-""
-record SimulationResult
-resultFile = "ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes_res.mat",
-simulationOptions = "startTime = 0.0, stopTime = 200.0, numberOfIntervals = 500, tolerance = 1e-06, method = 'dassl', fileNamePrefix = 'ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''",
-messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
-LOG_SUCCESS       | info    | The simulation finished successfully.
+
+"Warning: Out of memory! Faking a stack overflow.
+Error: Stack overflow occurred while evaluating loadModel(ThermoSysPro):
+[bt] [Symbols are not generated when running the test suite]
 "
+record SimulationResult
+resultFile = "",
+simulationOptions = "startTime = 0.0, stopTime = 200.0, numberOfIntervals = 500, tolerance = 1e-6, method = 'dassl', fileNamePrefix = 'ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''",
+messages = "Simulation Failed. Model: ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes does not exist! Please load it first before simulation."
 end SimulationResult;
-"[ThermoSysPro 3.2.0/FlueGases/Connectors.mo:3:3-51:22:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesOutlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.2.0/FlueGases/Connectors.mo:53:3-101:21:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesInlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.2.0/FlueGases/Connectors.mo:3:3-51:22:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesOutlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.2.0/FlueGases/Connectors.mo:53:3-101:21:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesInlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.2.0/FlueGases/Connectors.mo:3:3-51:22:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesOutlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.2.0/FlueGases/Connectors.mo:53:3-101:21:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesInlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.2.0/FlueGases/Connectors.mo:3:3-51:22:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesOutlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.2.0/FlueGases/Connectors.mo:53:3-101:21:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesInlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.2.0/FlueGases/Connectors.mo:3:3-51:22:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesOutlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.2.0/FlueGases/Connectors.mo:53:3-101:21:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesInlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.2.0/FlueGases/Connectors.mo:3:3-51:22:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesOutlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.2.0/FlueGases/Connectors.mo:53:3-101:21:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesInlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.2.0/FlueGases/Connectors.mo:3:3-51:22:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesOutlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.2.0/FlueGases/Connectors.mo:53:3-101:21:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesInlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.2.0/FlueGases/Connectors.mo:3:3-51:22:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesOutlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.2.0/FlueGases/Connectors.mo:53:3-101:21:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesInlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.2.0/FlueGases/Connectors.mo:3:3-51:22:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesOutlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.2.0/FlueGases/Connectors.mo:53:3-101:21:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesInlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.2.0/FlueGases/Connectors.mo:3:3-51:22:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesOutlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.2.0/FlueGases/Connectors.mo:53:3-101:21:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesInlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.2.0/FlueGases/Connectors.mo:3:3-51:22:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesOutlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.2.0/FlueGases/Connectors.mo:53:3-101:21:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesInlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.2.0/FlueGases/Connectors.mo:3:3-51:22:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesOutlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.2.0/FlueGases/Connectors.mo:53:3-101:21:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesInlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.2.0/FlueGases/Connectors.mo:3:3-51:22:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesOutlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.2.0/FlueGases/Connectors.mo:53:3-101:21:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesInlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.2.0/FlueGases/Connectors.mo:3:3-51:22:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesOutlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.2.0/FlueGases/Connectors.mo:53:3-101:21:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesInlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.2.0/FlueGases/Connectors.mo:3:3-51:22:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesOutlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.2.0/FlueGases/Connectors.mo:53:3-101:21:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesInlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.2.0/FlueGases/Connectors.mo:3:3-51:22:writable] Warning: Connector .ThermoSysPro.FlueGases.Connectors.FlueGasesOutlet is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0).
-Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts.
-"
-{"Files Equal!"}
+""
+"Error in compareSimulationResults"
'' 
Equation mismatch: omc-diff says: 
Line 3: Lexical token differs:
expected: true
got:      


== 1 out of 1 tests failed [simulation/libraries/3rdParty/ThermoSysPro/ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes.mos_temp464, time: 19]