Failed
tests / 01 testsuite-gcc 1/3 / simulation_modelica_NBackend_ScalableTestsuite.HeatingSystem.mos (from (result.xml))
Stacktrace
Output mismatch (see stdout for details)
Standard Output
+ ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5 ... equation mismatch [time: 13] ==== Log /tmp/omc-rtest-unknown/simulation/modelica/NBackend/ScalableTestsuite/HeatingSystem.mos_temp4505/log-HeatingSystem.mos true "" record SimulationResult resultFile = "", simulationOptions = "startTime = 0.0, stopTime = 432000.0, numberOfIntervals = 21600, tolerance = 1e-7, method = 'dassl', fileNamePrefix = 'ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = '-s=\\'ida\\''", messages = "Failed to build model: ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5" end SimulationResult; "Error: Error building simulator. Build log: gcc -O0 -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc/c\" -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=ScalableTestSuite_Thermal_DistrictHeating_ScaledExperiments_HeatingSystem_N_5 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=0 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5.o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5.c gcc -O0 -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc/c\" -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=ScalableTestSuite_Thermal_DistrictHeating_ScaledExperiments_HeatingSystem_N_5 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=0 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_functions.o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_functions.c gcc -O0 -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc/c\" -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=ScalableTestSuite_Thermal_DistrictHeating_ScaledExperiments_HeatingSystem_N_5 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=0 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_records.o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_records.c gcc -O0 -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc/c\" -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=ScalableTestSuite_Thermal_DistrictHeating_ScaledExperiments_HeatingSystem_N_5 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=0 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_01exo.o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_01exo.c gcc -O0 -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc/c\" -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=ScalableTestSuite_Thermal_DistrictHeating_ScaledExperiments_HeatingSystem_N_5 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=0 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_02nls.o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_02nls.c gcc -O0 -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc/c\" -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=ScalableTestSuite_Thermal_DistrictHeating_ScaledExperiments_HeatingSystem_N_5 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=0 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_03lsy.o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_03lsy.c gcc -O0 -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc/c\" -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=ScalableTestSuite_Thermal_DistrictHeating_ScaledExperiments_HeatingSystem_N_5 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=0 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_04set.o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_04set.c gcc -O0 -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc/c\" -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=ScalableTestSuite_Thermal_DistrictHeating_ScaledExperiments_HeatingSystem_N_5 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=0 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_05evt.o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_05evt.c gcc -O0 -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc/c\" -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=ScalableTestSuite_Thermal_DistrictHeating_ScaledExperiments_HeatingSystem_N_5 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=0 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_06inz.o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_06inz.c gcc -O0 -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc/c\" -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=ScalableTestSuite_Thermal_DistrictHeating_ScaledExperiments_HeatingSystem_N_5 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=0 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_07dly.o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_07dly.c gcc -O0 -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc/c\" -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=ScalableTestSuite_Thermal_DistrictHeating_ScaledExperiments_HeatingSystem_N_5 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=0 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_08bnd.o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_08bnd.c gcc -O0 -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc/c\" -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=ScalableTestSuite_Thermal_DistrictHeating_ScaledExperiments_HeatingSystem_N_5 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=0 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_09alg.o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_09alg.c gcc -O0 -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc/c\" -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=ScalableTestSuite_Thermal_DistrictHeating_ScaledExperiments_HeatingSystem_N_5 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=0 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_10asr.o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_10asr.c gcc -O0 -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc/c\" -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=ScalableTestSuite_Thermal_DistrictHeating_ScaledExperiments_HeatingSystem_N_5 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=0 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_11mix.o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_11mix.c gcc -O0 -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc/c\" -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=ScalableTestSuite_Thermal_DistrictHeating_ScaledExperiments_HeatingSystem_N_5 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=0 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_12jac.o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_12jac.c ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_12jac.c: In function 'ScalableTestSuite_Thermal_DistrictHeating_ScaledExperiments_HeatingSystem_N_5_eqFunction_29': ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_12jac.c:75:71: error: 'sum_real' undeclared (first use in this function) 75 | jacobian->tmpVars[6] /* $pDER_ODE_JAC.$FUN_2 JACOBIAN_TMP_VAR */ = (sum_real /* assuming real for unknown type! */_array(tmp2)) * (tmp3); | ^~~~~~~~ ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_12jac.c:75:71: note: each undeclared identifier is reported only once for each function it appears in ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_12jac.c:75:79: error: expected ')' before '_array' 75 | jacobian->tmpVars[6] /* $pDER_ODE_JAC.$FUN_2 JACOBIAN_TMP_VAR */ = (sum_real /* assuming real for unknown type! */_array(tmp2)) * (tmp3); | ~ ^ ~~~~~~ | ) ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_12jac.c: At top level: cc1: note: unrecognized command-line option '-Wno-parentheses-equality' may have been intended to silence earlier diagnostics make: *** [<builtin>: ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_12jac.o] Error 1 " "Error in compareSimulationResults" Equation mismatch: diff says: --- /tmp/omc-rtest-unknown/simulation/modelica/NBackend/ScalableTestsuite/HeatingSystem.mos_temp4505/equations-expected2024-01-20 04:04:04.376994231 +0000 +++ /tmp/omc-rtest-unknown/simulation/modelica/NBackend/ScalableTestsuite/HeatingSystem.mos_temp4505/equations-got2024-01-20 04:04:17.280662640 +0000 @@ -1,11 +1,36 @@ true "" record SimulationResult -resultFile = "ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_res.mat", +resultFile = "", simulationOptions = "startTime = 0.0, stopTime = 432000.0, numberOfIntervals = 21600, tolerance = 1e-7, method = 'dassl', fileNamePrefix = 'ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = '-s=\\'ida\\''", -messages = "LOG_SUCCESS | info | The initialization finished successfully without homotopy method. -LOG_SUCCESS | info | The simulation finished successfully. -" +messages = "Failed to build model: ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5" end SimulationResult; -"" -{"Files Equal!"} +"Error: Error building simulator. Build log: gcc -O0 -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc/c\" -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=ScalableTestSuite_Thermal_DistrictHeating_ScaledExperiments_HeatingSystem_N_5 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=0 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5.o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5.c +gcc -O0 -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc/c\" -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=ScalableTestSuite_Thermal_DistrictHeating_ScaledExperiments_HeatingSystem_N_5 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=0 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_functions.o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_functions.c +gcc -O0 -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc/c\" -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=ScalableTestSuite_Thermal_DistrictHeating_ScaledExperiments_HeatingSystem_N_5 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=0 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_records.o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_records.c +gcc -O0 -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc/c\" -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=ScalableTestSuite_Thermal_DistrictHeating_ScaledExperiments_HeatingSystem_N_5 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=0 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_01exo.o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_01exo.c +gcc -O0 -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc/c\" -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=ScalableTestSuite_Thermal_DistrictHeating_ScaledExperiments_HeatingSystem_N_5 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=0 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_02nls.o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_02nls.c +gcc -O0 -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc/c\" -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=ScalableTestSuite_Thermal_DistrictHeating_ScaledExperiments_HeatingSystem_N_5 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=0 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_03lsy.o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_03lsy.c +gcc -O0 -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc/c\" -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=ScalableTestSuite_Thermal_DistrictHeating_ScaledExperiments_HeatingSystem_N_5 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=0 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_04set.o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_04set.c +gcc -O0 -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc/c\" -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=ScalableTestSuite_Thermal_DistrictHeating_ScaledExperiments_HeatingSystem_N_5 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=0 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_05evt.o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_05evt.c +gcc -O0 -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc/c\" -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=ScalableTestSuite_Thermal_DistrictHeating_ScaledExperiments_HeatingSystem_N_5 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=0 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_06inz.o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_06inz.c +gcc -O0 -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc/c\" -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=ScalableTestSuite_Thermal_DistrictHeating_ScaledExperiments_HeatingSystem_N_5 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=0 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_07dly.o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_07dly.c +gcc -O0 -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc/c\" -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=ScalableTestSuite_Thermal_DistrictHeating_ScaledExperiments_HeatingSystem_N_5 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=0 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_08bnd.o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_08bnd.c +gcc -O0 -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc/c\" -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=ScalableTestSuite_Thermal_DistrictHeating_ScaledExperiments_HeatingSystem_N_5 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=0 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_09alg.o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_09alg.c +gcc -O0 -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc/c\" -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=ScalableTestSuite_Thermal_DistrictHeating_ScaledExperiments_HeatingSystem_N_5 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=0 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_10asr.o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_10asr.c +gcc -O0 -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc/c\" -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=ScalableTestSuite_Thermal_DistrictHeating_ScaledExperiments_HeatingSystem_N_5 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=0 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_11mix.o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_11mix.c +gcc -O0 -DOM_HAVE_PTHREADS -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc/c\" -I\"/var/lib/jenkins/ws/OpenModelica_PR-9221/build/bin/../include/omc\" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=ScalableTestSuite_Thermal_DistrictHeating_ScaledExperiments_HeatingSystem_N_5 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=0 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_12jac.o ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_12jac.c +ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_12jac.c: In function 'ScalableTestSuite_Thermal_DistrictHeating_ScaledExperiments_HeatingSystem_N_5_eqFunction_29': +ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_12jac.c:75:71: error: 'sum_real' undeclared (first use in this function) +75 | jacobian->tmpVars[6] /* $pDER_ODE_JAC.$FUN_2 JACOBIAN_TMP_VAR */ = (sum_real /* assuming real for unknown type! */_array(tmp2)) * (tmp3); +| ^~~~~~~~ +ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_12jac.c:75:71: note: each undeclared identifier is reported only once for each function it appears in +ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_12jac.c:75:79: error: expected ')' before '_array' +75 | jacobian->tmpVars[6] /* $pDER_ODE_JAC.$FUN_2 JACOBIAN_TMP_VAR */ = (sum_real /* assuming real for unknown type! */_array(tmp2)) * (tmp3); +| ~ ^ ~~~~~~ +| ) +ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_12jac.c: At top level: +cc1: note: unrecognized command-line option '-Wno-parentheses-equality' may have been intended to silence earlier diagnostics +make: *** [<builtin>: ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_5_12jac.o] Error 1 +" +"Error in compareSimulationResults" Equation mismatch: omc-diff says: Failed 'S' '"' Line 4: Text differs: expected: resultFile = "ScalableTestSuite.Thermal.DistrictHeating.ScaledExperiments.HeatingSystem_N_ got: resultFile = "", == 1 out of 1 tests failed [simulation/modelica/NBackend/ScalableTestsuite/HeatingSystem.mos_temp4505, time: 13]