Failed
tests / 05 testsuite-clang 2/3 / simulation_libraries_msl31.Modelica.Electrical.Machines.Examples.TransformerTestbench.mos (from (result.xml))
Stacktrace
Output mismatch (see stdout for details)
Standard Output
+ Modelica.Electrical.Machines.Examples.Transformers.TransformerTestbench ... equation mismatch [time: 6] ==== Log /tmp/omc-rtest-unknown/simulation/libraries/msl31/Modelica.Electrical.Machines.Examples.TransformerTestbench.mos_temp1146/log-Modelica.Electrical.Machines.Examples.TransformerTestbench.mos "true " "" "3.1" "msl31" OpenModelicaModelTesting.Kind.VerifiedSimulation OpenModelicaModelTesting.DiffAlgorithm.diffSimulationResults Modelica.Electrical.Machines.Examples.TransformerTestbench {"transformer.l2sigma.inductor[1].i","transformer.l2sigma.inductor[3].i"} Simulation options: startTime = 0.0, stopTime = 0.1, numberOfIntervals = 500, tolerance = 1e-6, method = 'dassl', fileNamePrefix = 'Modelica.Electrical.Machines.Examples.TransformerTestbench', options = '', outputFormat = 'mat', variableFilter = 'time|transformer.l2sigma.inductor.1..i|transformer.l2sigma.inductor.3..i', cflags = '', simflags = ' -abortSlowSimulation -alarm=360 -emit_protected' Result file: Modelica.Electrical.Machines.Examples.TransformerTestbench_res.mat Messages: LOG_STDOUT | info | Using sparse solver for linear system 0, | | | | because density of 0.091 remains under threshold of 0.200. LOG_STDOUT | info | Using sparse solver for linear system 1, | | | | because density of 0.091 remains under threshold of 0.200. LOG_STDOUT | info | The maximum density for using sparse solvers can be specified | | | | using the runtime flag '<-lssMaxDensity=value>'. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_SUCCESS | info | The simulation finished successfully. Files Equal! [Modelica 3.1.0+maint.om/Electrical/Machines.mo:7955:5-7956:40:writable] Warning: Parameter transformerData.P_sc has no value, and is fixed during initialization (fixed=true), using available start value (start=300.0) as default value. [Modelica 3.1.0+maint.om/Electrical/Machines.mo:7953:5-7954:36:writable] Warning: Parameter transformerData.v_sc has no value, and is fixed during initialization (fixed=true), using available start value (start=0.05) as default value. [Modelica 3.1.0+maint.om/Electrical/Machines.mo:7951:5-7952:33:writable] Warning: Parameter transformerData.SNominal has no value, and is fixed during initialization (fixed=true), using available start value (start=3e4) as default value. [Modelica 3.1.0+maint.om/Electrical/Machines.mo:7945:5-7946:86:writable] Warning: Parameter transformerData.V2 has no value, and is fixed during initialization (fixed=true), using available start value (start=100.0) as default value. [Modelica 3.1.0+maint.om/Electrical/Machines.mo:7940:5-7941:53:writable] Warning: Parameter transformerData.V1 has no value, and is fixed during initialization (fixed=true), using available start value (start=100.0) as default value. [Modelica 3.1.0+maint.om/Electrical/Machines.mo:7939:5-7939:73:writable] Warning: Parameter transformerData.f has no value, and is fixed during initialization (fixed=true), using available start value (start=50.0) as default value. Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions("-d=initialization"). "true " "" Equation mismatch: diff says: --- /tmp/omc-rtest-unknown/simulation/libraries/msl31/Modelica.Electrical.Machines.Examples.TransformerTestbench.mos_temp1146/equations-expected2024-01-13 02:57:07.534277855 +0000 +++ /tmp/omc-rtest-unknown/simulation/libraries/msl31/Modelica.Electrical.Machines.Examples.TransformerTestbench.mos_temp1146/equations-got2024-01-13 02:57:13.174239713 +0000 @@ -5,19 +5,25 @@ "msl31" OpenModelicaModelTesting.Kind.VerifiedSimulation OpenModelicaModelTesting.DiffAlgorithm.diffSimulationResults Modelica.Electrical.Machines.Examples.TransformerTestbench {"transformer.l2sigma.inductor[1].i","transformer.l2sigma.inductor[3].i"} -Simulation options: startTime = 0.0, stopTime = 0.1, numberOfIntervals = 500, tolerance = 1e-06, method = 'dassl', fileNamePrefix = 'Modelica.Electrical.Machines.Examples.TransformerTestbench', options = '', outputFormat = 'mat', variableFilter = 'time|transformer.l2sigma.inductor.1..i|transformer.l2sigma.inductor.3..i', cflags = '', simflags = ' -abortSlowSimulation -alarm=360 -emit_protected' +Simulation options: startTime = 0.0, stopTime = 0.1, numberOfIntervals = 500, tolerance = 1e-6, method = 'dassl', fileNamePrefix = 'Modelica.Electrical.Machines.Examples.TransformerTestbench', options = '', outputFormat = 'mat', variableFilter = 'time|transformer.l2sigma.inductor.1..i|transformer.l2sigma.inductor.3..i', cflags = '', simflags = ' -abortSlowSimulation -alarm=360 -emit_protected' Result file: Modelica.Electrical.Machines.Examples.TransformerTestbench_res.mat -Messages: LOG_SUCCESS | info | The initialization finished successfully without homotopy method. +Messages: LOG_STDOUT | info | Using sparse solver for linear system 0, +| | | | because density of 0.091 remains under threshold of 0.200. +LOG_STDOUT | info | Using sparse solver for linear system 1, +| | | | because density of 0.091 remains under threshold of 0.200. +LOG_STDOUT | info | The maximum density for using sparse solvers can be specified +| | | | using the runtime flag '<-lssMaxDensity=value>'. +LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_SUCCESS | info | The simulation finished successfully. Files Equal! [Modelica 3.1.0+maint.om/Electrical/Machines.mo:7955:5-7956:40:writable] Warning: Parameter transformerData.P_sc has no value, and is fixed during initialization (fixed=true), using available start value (start=300.0) as default value. [Modelica 3.1.0+maint.om/Electrical/Machines.mo:7953:5-7954:36:writable] Warning: Parameter transformerData.v_sc has no value, and is fixed during initialization (fixed=true), using available start value (start=0.05) as default value. -[Modelica 3.1.0+maint.om/Electrical/Machines.mo:7951:5-7952:33:writable] Warning: Parameter transformerData.SNominal has no value, and is fixed during initialization (fixed=true), using available start value (start=30000.0) as default value. +[Modelica 3.1.0+maint.om/Electrical/Machines.mo:7951:5-7952:33:writable] Warning: Parameter transformerData.SNominal has no value, and is fixed during initialization (fixed=true), using available start value (start=3e4) as default value. [Modelica 3.1.0+maint.om/Electrical/Machines.mo:7945:5-7946:86:writable] Warning: Parameter transformerData.V2 has no value, and is fixed during initialization (fixed=true), using available start value (start=100.0) as default value. [Modelica 3.1.0+maint.om/Electrical/Machines.mo:7940:5-7941:53:writable] Warning: Parameter transformerData.V1 has no value, and is fixed during initialization (fixed=true), using available start value (start=100.0) as default value. [Modelica 3.1.0+maint.om/Electrical/Machines.mo:7939:5-7939:73:writable] Warning: Parameter transformerData.f has no value, and is fixed during initialization (fixed=true), using available start value (start=50.0) as default value. Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->Show additional information from the initialization process, in OMNotebook call setCommandLineOptions("-d=initialization"). Equation mismatch: omc-diff says: Failed 'U' 'T' Line 12: Text differs: expected: Messages: LOG_SUCCESS | info | The initialization finished successfully without homotopy method. got: Messages: LOG_STDOUT | info | Using sparse solver for linear system == 1 out of 1 tests failed [simulation/libraries/msl31/Modelica.Electrical.Machines.Examples.TransformerTestbench.mos_temp1146, time: 6]