Skip to content

Passed

tests / 08 testsuite-compliance / ModelicaCompliance.Classes.Enumeration.WrongConversion6.WrongConversion6 (from omc OMCompiler v1.24.0-dev.89+g0c6cfc383b compliance suite 3.2)

Took 0.29 sec.

Standard Output

Failed to build model: ModelicaCompliance.Classes.Enumeration.WrongConversion6[/var/lib/jenkins2/ws/OpenModelica_master/libraries/.openmodelica/libraries/ModelicaCompliance 3.2.0-master/Classes/Enumeration/WrongConversion6.mo:23:3-23:18:writable] Warning: Connector y is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0).
[/var/lib/jenkins2/ws/OpenModelica_master/libraries/.openmodelica/libraries/ModelicaCompliance 3.2.0-master/Classes/Enumeration/WrongConversion6.mo:26:3-26:8:writable] Error: Type mismatch in equation y = 1 of type enumeration Init(one, two, three) = Integer.