Skip to content

Skipped

tests / testsuite-compliance / ModelicaCompliance.Connections.Restrictions.SizeOverconstrainedInvalid.SizeOverconstrainedInvalid (from omc OMCompiler v1.20.0-v1.20.0.1+g2faf7aa0ea compliance suite 3.2)

Skipped for the past 11 builds (Since #0 )
Took 3.6 sec.

Skip Message

This testcase still fails (as expected)

Standard Output

LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
[/var/lib/jenkins1/ws/OpenModelica_maintenance_v1.20/libraries/.openmodelica/libraries/ModelicaCompliance 3.2.0-master/Connections/Restrictions/SizeOverconstrainedInvalid.mo:29:3-29:61:writable] Warning: Connector f is not balanced: The number of potential variables (5) is not equal to the number of flow variables (6).

Succeeded, but expected failure