Failed
tests / testsuite-clang / simulation_modelica_hpcom.Modelica.Electrical.Analog.Examples.SwitchWithArc.mos (from (result.xml))
Failing for the past 9 builds
(Since Failed )
Stacktrace
Output mismatch (see stdout for details)
Standard Output
+ Modelica.Electrical.Analog.Examples.SwitchWithArc ... equation mismatch [time: 0] ==== Log /tmp/omc-rtest-unknown/simulation/modelica/hpcom/Modelica.Electrical.Analog.Examples.SwitchWithArc.mos_temp826/log-Modelica.Electrical.Analog.Examples.SwitchWithArc.mos false true true true "Error: Failed to load package Modelica (3.2.1) using MODELICAPATH /var/lib/jenkins/workspace/OpenModelica_maintenance_v1.13/build/lib/omlibrary. " true "" record SimulationResult resultFile = "", simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 500, tolerance = 1e-06, method = 'dassl', fileNamePrefix = 'Modelica.Electrical.Analog.Examples.SwitchWithArc', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''", messages = "Simulation Failed. Model: Modelica.Electrical.Analog.Examples.SwitchWithArc does not exist! Please load it first before simulation." end SimulationResult; "" {"Error opening file: /var/lib/jenkins/workspace/OpenModelica_maintenance_v1.13/testsuite/simulation/modelica/hpcom/Modelica.Electrical.Analog.Examples.SwitchWithArc.mos_temp826/Modelica.Electrical.Analog.Examples.SwitchWithArc_res.mat"} Equation mismatch: diff says: --- /tmp/omc-rtest-unknown/simulation/modelica/hpcom/Modelica.Electrical.Analog.Examples.SwitchWithArc.mos_temp826/equations-expected2019-01-31 14:13:08.038121793 +0000 +++ /tmp/omc-rtest-unknown/simulation/modelica/hpcom/Modelica.Electrical.Analog.Examples.SwitchWithArc.mos_temp826/equations-got2019-01-31 14:13:08.102121122 +0000 @@ -1,25 +1,15 @@ +false true true true +"Error: Failed to load package Modelica (3.2.1) using MODELICAPATH /var/lib/jenkins/workspace/OpenModelica_maintenance_v1.13/build/lib/omlibrary. +" true "" -true -"" -readCalcTimesFromFile: No valid profiling-file found. -Warning: The costs have been estimated. Maybe Modelica.Electrical.Analog.Examples.SwitchWithArc_eqs_prof-file is missing. -Using list Scheduler for the DAE system -Using list Scheduler for the ODE system -Using list Scheduler for the ZeroFunc system -There is no parallel potential in the ODE system model! -The ODE system model is not big enough to perform an effective parallel simulation! -HpcOm is still under construction. record SimulationResult -resultFile = "Modelica.Electrical.Analog.Examples.SwitchWithArc_res.mat", -simulationOptions = "startTime = 0.0, stopTime = 2.0, numberOfIntervals = 8000, tolerance = 1e-06, method = 'dassl', fileNamePrefix = 'Modelica.Electrical.Analog.Examples.SwitchWithArc', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''", -messages = "LOG_SUCCESS | info | The initialization finished successfully without homotopy method. -LOG_SUCCESS | info | The simulation finished successfully. -" +resultFile = "", +simulationOptions = "startTime = 0.0, stopTime = 1.0, numberOfIntervals = 500, tolerance = 1e-06, method = 'dassl', fileNamePrefix = 'Modelica.Electrical.Analog.Examples.SwitchWithArc', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''", +messages = "Simulation Failed. Model: Modelica.Electrical.Analog.Examples.SwitchWithArc does not exist! Please load it first before simulation." end SimulationResult; -"Warning: There are iteration variables with default zero start attribute. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization"). -" -{"Files Equal!"} +"" +{"Error opening file: /var/lib/jenkins/workspace/OpenModelica_maintenance_v1.13/testsuite/simulation/modelica/hpcom/Modelica.Electrical.Analog.Examples.SwitchWithArc.mos_temp826/Modelica.Electrical.Analog.Examples.SwitchWithArc_res.mat"} Equation mismatch: omc-diff says: Failed 't' 'f' Line 1: Text differs: expected: true got: false == 1 out of 1 tests failed [simulation/modelica/hpcom/Modelica.Electrical.Analog.Examples.SwitchWithArc.mos_temp826, time: 0]