Skip to content

Failed

tests / testsuite-clang / simulation_libraries_3rdParty_ThermoSysPro.ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4.mos (from (result.xml))

Failing for the past 5 builds (Since #27 )
Took 22 sec.

Stacktrace

Output mismatch (see stdout for details)

Standard Output

 + ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4.mos [simulation checking]... equation mismatch [time: 22]

==== Log /tmp/omc-rtest-unknown/simulation/libraries/3rdParty/ThermoSysPro/ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4.mos_temp7107/log-ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4.mos
true
""
true
""
record SimulationResult
    resultFile = "ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4_res.mat",
    simulationOptions = "startTime = 0.0, stopTime = 1000.0, numberOfIntervals = 500, tolerance = 1e-06, method = 'dassl', fileNamePrefix = 'ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''",
    messages = "LOG_SUCCESS       | info    | The initialization finished successfully without homotopy method.
LOG_SUCCESS       | info    | The simulation finished successfully.
"
end SimulationResult;
"[ThermoSysPro 3.2/WaterSteam/Connectors.mo:3:3-43:17:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.2/WaterSteam/Connectors.mo:87:3-127:18:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidOutlet$centrifugalPump1$C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.2/ElectroMechanics/Connectors.mo:3:3-36:24:writable] Warning: Connector .ThermoSysPro.ElectroMechanics.Connectors.MechanichalTorque is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0).
[ThermoSysPro 3.2/Properties/WaterSteam/Common.mo:1494:3-1528:30:writable] Warning: sat.T was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2/Properties/WaterSteam/Common.mo:1494:3-1528:30:writable] Warning: sat.dpT was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.T was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.dpT was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.cpt was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.vt was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.vp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.vtt was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.vpp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.vtp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2/Properties/WaterSteam/IF97_packages.mo:1089:9-1089:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2/Properties/WaterSteam/IF97_packages.mo:851:9-851:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2/Properties/WaterSteam/IF97_packages.mo:784:9-784:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2/Properties/WaterSteam/Common.mo:162:3-214:22:writable] Warning: pro.x was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2/Properties/WaterSteam/Common.mo:252:3-295:26:writable] Warning: pro.duph was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2/Properties/WaterSteam/Common.mo:252:3-295:26:writable] Warning: pro.duhp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2/Properties/WaterSteam/Common.mo:252:3-295:26:writable] Warning: pro.x was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2/Properties/WaterSteam/Common.mo:1270:3-1340:18:writable] Warning: pro.duph was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2/Properties/WaterSteam/Common.mo:1270:3-1340:18:writable] Warning: pro.duhp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2/Properties/C3H3F5/C3H3F5_Ph.mo:2:1-131:14:writable] Warning: pro.u was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2/Properties/C3H3F5/C3H3F5_Ph.mo:2:1-131:14:writable] Warning: pro.cp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2/Properties/C3H3F5/C3H3F5_Ph.mo:2:1-131:14:writable] Warning: pro.ddhp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2/Properties/C3H3F5/C3H3F5_Ph.mo:2:1-131:14:writable] Warning: pro.ddph was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2/Properties/C3H3F5/C3H3F5_Ph.mo:2:1-131:14:writable] Warning: pro.duph was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2/Properties/C3H3F5/C3H3F5_Ph.mo:2:1-131:14:writable] Warning: pro.duhp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2/Properties/WaterSteamSimple/prop4_Ph_der.mo:179:3-182:49:writable] Warning: du1satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2/Properties/WaterSteamSimple/prop4_Ph_der.mo:179:3-182:49:writable] Warning: du2satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2/Properties/WaterSteamSimple/prop4_Ph.mo:76:3-76:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2/Properties/WaterSteamSimple/prop4_Ph.mo:76:3-76:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.2/WaterSteam/Connectors.mo:3:3-43:17:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.2/WaterSteam/Connectors.mo:87:3-127:18:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidOutlet$Tank$Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.2/WaterSteam/Connectors.mo:3:3-43:17:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.2/WaterSteam/Connectors.mo:87:3-127:18:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.2/WaterSteam/Connectors.mo:3:3-43:17:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.2/WaterSteam/Connectors.mo:87:3-127:18:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.2/WaterSteam/Connectors.mo:3:3-43:17:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidInlet$lumpedStraightPipe$C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.2/WaterSteam/Connectors.mo:87:3-127:18:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.2/ElectroMechanics/Connectors.mo:3:3-36:24:writable] Warning: Connector .ThermoSysPro.ElectroMechanics.Connectors.MechanichalTorque is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0).
Warning: The model contains alias variables with conflicting start and/or nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts.
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
"
{"Files Equal!"}

Equation mismatch: diff says:
--- /tmp/omc-rtest-unknown/simulation/libraries/3rdParty/ThermoSysPro/ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4.mos_temp7107/equations-expected2020-01-16 10:14:02.188944623 +0000
+++ /tmp/omc-rtest-unknown/simulation/libraries/3rdParty/ThermoSysPro/ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4.mos_temp7107/equations-got2020-01-16 10:14:24.329317440 +0000
@@ -48,10 +48,9 @@
 [ThermoSysPro 3.2/WaterSteam/Connectors.mo:3:3-43:17:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
 [ThermoSysPro 3.2/WaterSteam/Connectors.mo:87:3-127:18:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
 [ThermoSysPro 3.2/WaterSteam/Connectors.mo:3:3-43:17:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidInlet$lumpedStraightPipe$C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
 [ThermoSysPro 3.2/WaterSteam/Connectors.mo:87:3-127:18:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
 [ThermoSysPro 3.2/ElectroMechanics/Connectors.mo:3:3-36:24:writable] Warning: Connector .ThermoSysPro.ElectroMechanics.Connectors.MechanichalTorque is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0).
-[ThermoSysPro 3.2/WaterSteam/Machines/CentrifugalPump.mo:137:3-139:9:writable] Error: Missing else-clause in if-equation with non-parameter conditions.
 Warning: The model contains alias variables with conflicting start and/or nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts.
 Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
 "
 {"Files Equal!"}

Equation mismatch: omc-diff says:
Failed '[' 'W'
Line 53: Text differs:
expected: [ThermoSysPro 
got:      Warning: The model contains alias variables with conflicting start and/or nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use 

== 1 out of 1 tests failed [simulation/libraries/3rdParty/ThermoSysPro/ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4.mos_temp7107, time: 22]