Skip to content

Passed

tests / testsuite-compliance / ModelicaCompliance.Components.Conditional.ModifiedConditionUnbalanced.ModifiedConditionUnbalanced (from omc OMCompiler v1.14.1-v1.14.1.2+g392c27e260 compliance suite 3.2)

Took 0.82 sec.

Standard Output

Failed to build model: ModelicaCompliance.Components.Conditional.ModifiedConditionUnbalancedError: Too many equations, over-determined system. The model has 6 equation(s) and 4 variable(s).
[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_2/build/lib/omlibrary/ModelicaCompliance 3.2/Components/Conditional/ModifiedConditionUnbalanced.mo:17:5-17:20:writable] Warning: Equation 5 (size: 1) m.c1.e = m.c2.e is not big enough to solve for enough variables.
  Remaining unsolved variables are: 
  Alr
...[truncated 117 chars]...
ation 2 (size: 1): m.c2.e = 1.0
[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_2/build/lib/omlibrary/ModelicaCompliance 3.2/Components/Conditional/ModifiedConditionUnbalanced.mo:17:5-17:20:writable] Warning: Equation 6 (size: 1) (-m.c1.f) - m.c2.f = 0.0 is not big enough to solve for enough variables.
  Remaining unsolved variables are: 
  Already solved: m.c1.f, m.c2.f
  Equations used to solve those variables:
    Equation 3 (size: 1): m.c1.f = 0.0
    Equation 4 (size: 1): m.c2.f = 0.0