Skip to content

Passed

tests / testsuite-compliance / ModelicaCompliance.Classes.Balancing.WrongBalance.WrongBalance (from omc OMCompiler v1.14.1-v1.14.1.2+g392c27e260 compliance suite 3.2)

Took 0.63 sec.

Standard Output

Failed to build model: ModelicaCompliance.Classes.Balancing.WrongBalanceError: Too many equations, over-determined system. The model has 3 equation(s) and 2 variable(s).
[/var/lib/jenkins3/ws/OpenModelica_maintenance_v1.14_2/build/lib/omlibrary/ModelicaCompliance 3.2/Classes/Balancing/WrongBalance.mo:22:5-22:25:writable] Warning: Equation 3 (size: 1) example.correlation.y = time is not big enough to solve for enough variables.
  Remaining unsolved variables are: 
  Already solved: example.correlation.y
  Equations used to solve those variables:
    Equation 2 (size: 1): example.correlation.y = 2.0 / example.correlation.x