Failed
tests / 02 testsuite-gcc 2/3 / simulation_modelica_initialization.OverdeterminedInitialization.Fluid.DynamicPipeInitialValues.mos (from (result.xml))
Stacktrace
Output mismatch (see stdout for details)
Standard Output
+ OverdeterminedInitialization.Fluid.DynamicPipeInitialValues ... equation mismatch [time: 24] ==== Log /tmp/omc-rtest-omtmpuser/simulation/modelica/initialization/OverdeterminedInitialization.Fluid.DynamicPipeInitialValues.mos_temp9603/log-OverdeterminedInitialization.Fluid.DynamicPipeInitialValues.mos true "" true "" true "" is no flow -1e5: false is no flow -1e60: false is no flow -1e5: false is no flow -1e60: false is no flow -1e60: false is no flow -1e60: false is no flow -1e60: false is no flow -1e60: false is no flow -1e60: false is no flow -1e60: false is no flow -1e60: false is no flow -1e5: false is no flow -1e5: false is no flow -1e60: false record SimulationResult resultFile = "OverdeterminedInitialization.Fluid.DynamicPipeInitialValues_res.mat", simulationOptions = "startTime = 0.0, stopTime = 4.0, numberOfIntervals = 500, tolerance = 1e-6, method = 'dassl', fileNamePrefix = 'OverdeterminedInitialization.Fluid.DynamicPipeInitialValues', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''", messages = "LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_SUCCESS | info | The simulation finished successfully. " end SimulationResult; "Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Warning: Assuming fixed start value for the following 1 variables: m_flow_initial:DISCRETE(unit = \"kg/s\" fixed = true ) type: Real Warning: The initial conditions are over specified. The following 1 initial equations are redundant, so they are removed from the initialization system: pipe.mediums[1].p = 1e7. Warning: Assuming fixed start value for the following 1 variables: m_flow_initial:DISCRETE(unit = \"kg/s\" fixed = true ) type: Real Warning: The initial conditions are over specified. The following 1 initial equations are redundant, so they are removed from the initialization_lambda0 system: pipe.mediums[1].p = 1e7. " Equation mismatch: diff says: --- /tmp/omc-rtest-omtmpuser/simulation/modelica/initialization/OverdeterminedInitialization.Fluid.DynamicPipeInitialValues.mos_temp9603/equations-expected2024-06-14 13:48:46.322527970 +0000 +++ /tmp/omc-rtest-omtmpuser/simulation/modelica/initialization/OverdeterminedInitialization.Fluid.DynamicPipeInitialValues.mos_temp9603/equations-got2024-06-14 13:49:10.733882054 +0000 @@ -2,22 +2,36 @@ "" true "" true "" +is no flow -1e5: false +is no flow -1e60: false +is no flow -1e5: false +is no flow -1e60: false +is no flow -1e60: false +is no flow -1e60: false +is no flow -1e60: false +is no flow -1e60: false +is no flow -1e60: false +is no flow -1e60: false +is no flow -1e60: false +is no flow -1e5: false +is no flow -1e5: false +is no flow -1e60: false record SimulationResult resultFile = "OverdeterminedInitialization.Fluid.DynamicPipeInitialValues_res.mat", -simulationOptions = "startTime = 0.0, stopTime = 4.0, numberOfIntervals = 500, tolerance = 1e-06, method = 'dassl', fileNamePrefix = 'OverdeterminedInitialization.Fluid.DynamicPipeInitialValues', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''", +simulationOptions = "startTime = 0.0, stopTime = 4.0, numberOfIntervals = 500, tolerance = 1e-6, method = 'dassl', fileNamePrefix = 'OverdeterminedInitialization.Fluid.DynamicPipeInitialValues', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''", messages = "LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_SUCCESS | info | The simulation finished successfully. " end SimulationResult; "Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Warning: Assuming fixed start value for the following 1 variables: m_flow_initial:DISCRETE(unit = \"kg/s\" fixed = true ) type: Real Warning: The initial conditions are over specified. The following 1 initial equations are redundant, so they are removed from the initialization system: -pipe.mediums[1].p = 10000000.0. +pipe.mediums[1].p = 1e7. Warning: Assuming fixed start value for the following 1 variables: m_flow_initial:DISCRETE(unit = \"kg/s\" fixed = true ) type: Real Warning: The initial conditions are over specified. The following 1 initial equations are redundant, so they are removed from the initialization_lambda0 system: -pipe.mediums[1].p = 10000000.0. +pipe.mediums[1].p = 1e7. " Equation mismatch: omc-diff says: Failed 'r' 'i' Line 7: Text differs: expected: record SimulationResult got: is no flow == 1 out of 1 tests failed [simulation/modelica/initialization/OverdeterminedInitialization.Fluid.DynamicPipeInitialValues.mos_temp9603, time: 24]