Failedsimulation_libraries_3rdParty_ThermoSysPro.ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution.mos
(from (result.xml))
Failing for the past 2,133 builds
(Since
#9156
)
StacktraceOutput mismatch (see stdout for details) Standard Output + ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution.mos [simulation checking]... equation mismatch [time: 6]
==== Log /tmp/omc-rtest-adrpo33/simulation/libraries/3rdParty/ThermoSysPro/ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution.mos_temp4355/log-ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution.mos
true
""
true
""
record SimulationResult
resultFile = "",
simulationOptions = "startTime = 0.0, stopTime = 1000.0, numberOfIntervals = 500, tolerance = 1e-006, method = 'dassl', fileNamePrefix = 'ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''",
messages = "Failed to build model: ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution"
end SimulationResult;
"[ThermoSysPro 3.1/WaterSolution/Connectors.mo:3:3-43:25:writable] Warning: Connector .ThermoSysPro.WaterSolution.Connectors.WaterSolutionInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.1/WaterSolution/Connectors.mo:45:3-85:26:writable] Warning: Connector .ThermoSysPro.WaterSolution.Connectors.WaterSolutionOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.1/WaterSolution/Connectors.mo:3:3-43:25:writable] Warning: Connector .ThermoSysPro.WaterSolution.Connectors.WaterSolutionInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.1/WaterSolution/Connectors.mo:45:3-85:26:writable] Warning: Connector .ThermoSysPro.WaterSolution.Connectors.WaterSolutionOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.1/Properties/WaterSteam/Common.mo:703:3-754:22:writable] Warning: pro.x was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.1/Properties/WaterSteam/Common.mo:1185:3-1241:26:writable] Warning: pro.x was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.1/WaterSolution/Connectors.mo:45:3-85:26:writable] Warning: Connector .ThermoSysPro.WaterSolution.Connectors.WaterSolutionOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.1/WaterSolution/Connectors.mo:3:3-43:25:writable] Warning: Connector .ThermoSysPro.WaterSolution.Connectors.WaterSolutionInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
Error: File.open: Failed to open file ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution_info.json with mode 2: No such file or directory
[SimCode/SerializeModelInfo.mo:0:0-0:0:writable] Error: Internal error SerializeModelInfo.serialize failed
[SimCode/SimCodeMain.mo:0:0-0:0:writable] Error: Internal error C:\dev\hudson\workspace\OM_Win\OM\build\bin\omc.exe: [unknown function name] failed
Error: File.open: Failed to open file ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution_functions.c with mode 2: No such file or directory
[SimCode/SimCodeMain.mo:0:0-0:0:writable] Error: Internal error C:\dev\hudson\workspace\OM_Win\OM\build\bin\omc.exe: [unknown function name] failed
Error: File.open: Failed to open file ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution_literals.h with mode 2: No such file or directory
Error: Template error: A template call failed (C:\dev\hudson\workspace\OM_Win\OM\build\bin\omc.exe: [unknown function name]). One possible reason could be that a template imported function call failed (which should not happen for functions called from within template code; templates assert pure 'match'/non-failing semantics).
[SimCode/SimCodeMain.mo:0:0-0:0:writable] Error: Internal error C:\dev\hudson\workspace\OM_Win\OM\build\bin\omc.exe: [unknown function name] failed
Error: File.open: Failed to open file ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution_init.xml with mode 2: No such file or directory
[SimCode/SimCodeMain.mo:0:0-0:0:writable] Error: Internal error C:\dev\hudson\workspace\OM_Win\OM\build\bin\omc.exe: [unknown function name] failed
"
{"Error opening file: C:/dev/hudson/workspace/OM_Win/OM/testsuite/simulation/libraries/3rdParty/ThermoSysPro/ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution.mos_temp4355/ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution_res.mat"}
Equation mismatch: diff says:
--- /tmp/omc-rtest-adrpo33/simulation/libraries/3rdParty/ThermoSysPro/ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution.mos_temp4355/equations-expected2019-05-15 13:35:50.740306600 +0200
+++ /tmp/omc-rtest-adrpo33/simulation/libraries/3rdParty/ThermoSysPro/ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution.mos_temp4355/equations-got2019-05-15 13:35:56.599303100 +0200
@@ -1,25 +1,30 @@
true
""
true
""
record SimulationResult
-resultFile = "ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution_res.mat",
-simulationOptions = "startTime = 0.0, stopTime = 1000.0, numberOfIntervals = 500, tolerance = 1e-06, method = 'dassl', fileNamePrefix = 'ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''",
-messages = "LOG_SUCCESS | info | The initialization finished successfully without homotopy method.
-assert | warning | The following assertion has been violated at time 200.000000
-| | | | staticCentrifugalPumpWaterLiBr.deltaP >= 0.0
-assert | warning | Variable violating min constraint: 0.0 <= staticCentrifugalPumpWaterLiBr.deltaP, has value: -86.9556
-LOG_SUCCESS | info | The simulation finished successfully.
-"
+resultFile = "",
+simulationOptions = "startTime = 0.0, stopTime = 1000.0, numberOfIntervals = 500, tolerance = 1e-006, method = 'dassl', fileNamePrefix = 'ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''",
+messages = "Failed to build model: ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution"
end SimulationResult;
"[ThermoSysPro 3.1/WaterSolution/Connectors.mo:3:3-43:25:writable] Warning: Connector .ThermoSysPro.WaterSolution.Connectors.WaterSolutionInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.1/WaterSolution/Connectors.mo:45:3-85:26:writable] Warning: Connector .ThermoSysPro.WaterSolution.Connectors.WaterSolutionOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.1/WaterSolution/Connectors.mo:3:3-43:25:writable] Warning: Connector .ThermoSysPro.WaterSolution.Connectors.WaterSolutionInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.1/WaterSolution/Connectors.mo:45:3-85:26:writable] Warning: Connector .ThermoSysPro.WaterSolution.Connectors.WaterSolutionOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.1/Properties/WaterSteam/Common.mo:703:3-754:22:writable] Warning: pro.x was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.1/Properties/WaterSteam/Common.mo:1185:3-1241:26:writable] Warning: pro.x was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
[ThermoSysPro 3.1/WaterSolution/Connectors.mo:45:3-85:26:writable] Warning: Connector .ThermoSysPro.WaterSolution.Connectors.WaterSolutionOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
[ThermoSysPro 3.1/WaterSolution/Connectors.mo:3:3-43:25:writable] Warning: Connector .ThermoSysPro.WaterSolution.Connectors.WaterSolutionInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
Warning: The initial conditions are not fully specified. For more information set -d=initialization. In OMEdit Tools->Options->Simulation->OMCFlags, in OMNotebook call setCommandLineOptions("-d=initialization").
+Error: File.open: Failed to open file ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution_info.json with mode 2: No such file or directory
+[SimCode/SerializeModelInfo.mo:0:0-0:0:writable] Error: Internal error SerializeModelInfo.serialize failed
+[SimCode/SimCodeMain.mo:0:0-0:0:writable] Error: Internal error C:\dev\hudson\workspace\OM_Win\OM\build\bin\omc.exe: [unknown function name] failed
+Error: File.open: Failed to open file ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution_functions.c with mode 2: No such file or directory
+[SimCode/SimCodeMain.mo:0:0-0:0:writable] Error: Internal error C:\dev\hudson\workspace\OM_Win\OM\build\bin\omc.exe: [unknown function name] failed
+Error: File.open: Failed to open file ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution_literals.h with mode 2: No such file or directory
+Error: Template error: A template call failed (C:\dev\hudson\workspace\OM_Win\OM\build\bin\omc.exe: [unknown function name]). One possible reason could be that a template imported function call failed (which should not happen for functions called from within template code; templates assert pure 'match'/non-failing semantics).
+[SimCode/SimCodeMain.mo:0:0-0:0:writable] Error: Internal error C:\dev\hudson\workspace\OM_Win\OM\build\bin\omc.exe: [unknown function name] failed
+Error: File.open: Failed to open file ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution_init.xml with mode 2: No such file or directory
+[SimCode/SimCodeMain.mo:0:0-0:0:writable] Error: Internal error C:\dev\hudson\workspace\OM_Win\OM\build\bin\omc.exe: [unknown function name] failed
"
-{"Files Equal!"}
+{"Error opening file: C:/dev/hudson/workspace/OM_Win/OM/testsuite/simulation/libraries/3rdParty/ThermoSysPro/ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution_res.mat"}
Equation mismatch: omc-diff says:
Failed 'T' '"'
Line 6: Text differs:
expected: resultFile = "ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution_res.mat",
got: resultFile = "",
== 1 out of 1 tests failed [simulation/libraries/3rdParty/ThermoSysPro/ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution.mos_temp4355, time: 7]
|